Search NASA⌕ Search

DOE OSTI · 21032794

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware

Abstract

The successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm. Reference images are DTS image sets reconstructed from digitally reconstructed radiographs (DRRs) previously generated from conventional planning CT data. Generating a set of DRRs from planning CT is relatively slow using the conventional ray-casting algorithm. In order to facilitate DTS reconstruction within a clinically acceptable period of time, we implemented a high performance DRR reconstruction algorithm on a graphics processing unit of commercial PC graphics hardware. The performance of this new algorithm was evaluated and compared with that which is achieved using the conventional software-based ray-casting algorithm. DTS images were reconstructed from DRRs previously generated by both hardware and software algorithms. On average, the DRR reconstruction efficiency using the hardware method is improved by a factor of 67 over the software method. The image quality of the DRRs was comparable to those generated using the software-based ray-casting algorithm. Accelerated DRR reconstruction significantly reduces the overall time required to produce a set of reference DTS images from planning CT and makes this technique clinically practical for target localization for radiation therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hui, Yan, Lei, Ren, Godfrey, Devon J, Fangfang, Yin. 2007-10-15. Accelerating reconstruction of reference digital tomosynthesis using graphics hardware. https://doi.org/10.1118/1.2779945. https://searchnasa.com/record/osti%3A21032794/accelerating-reconstruction-of-reference-digital-tomosynthesis-using-graphics-hardware

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗