Search NASA⌕ Search

Engineering topics

Lei, Ren

Publications and source records attributed to Lei, Ren.

Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study

Purpose: Setup errors and prostate intrafraction motion are main sources of localization uncertainty in prostate cancer radiation therapy. This study evaluates four different imaging modalities 3D ultrasound (US), kV planar images, cone-beam computed tomography (CBCT), and implanted electromagnetic transponders (Calypso/Varian) to assess inter- and intrafraction localization errors during intensity-modulated radiation therapy based treatment of prostate cancer. Methods: Twenty-seven prostate cancer patients were enrolled in a prospective IRB-approved study and treated to a total dose of 75.6 Gy (1.8 Gy/fraction). Overall, 1100 fractions were evaluated. For each fraction, treatment targets were localized using US, kV planar images, and CBCT in a sequence defined to determine setup offsets relative to the patient skin tattoos, intermodality differences, and residual errors for each patient and patient cohort. Planning margins, following van Herk's formalism, were estimated based on error distributions. Calypso-based localization was not available for the first eight patients, therefore centroid positions of implanted gold-seed markers imaged prior to and immediately following treatment were used as a motion surrogate during treatment. For the remaining 19 patients, Calypso transponders were used to assess prostate intrafraction motion. Results: The means ({mu}), and standard deviations (SD) of the systematic ({Sigma}) and random errors ({sigma}) of interfraction prostate shifts (relative to initial skin tattoo positioning), as evaluated using CBCT, kV, and US, averaged over all patients and fractions, were: [{mu}{sub CBCT}= (-1.2, 0.2, 1.1) mm, {Sigma}{sub CBCT}= (3.0, 1.4, 2.4) mm, {sigma}{sub CBCT}= (3.2, 2.2, 2.5) mm], [{mu}{sub kV}= (-2.9, -0.4, 0.5) mm, {Sigma}{sub kV}= (3.4, 3.1, 2.6) mm, {sigma}{sub kV}= (2.9, 2.0, 2.4) mm], and [{mu}{sub US}= (-3.6, -1.4, 0.0) mm, {Sigma}{sub US}= (3.3, 3.5, 2.8) mm, {sigma}{sub US}= (4.1, 3.8, 3.6) mm], in the anterior-posterior (A/P), superior-inferior (S/I), and the left-right (L/R) directions, respectively. In the treatment protocol, adjustment of couch was guided by US images. Residual setup errors as assessed by kV images were found to be: {mu}{sub residual}= (-0.4, 0.2, 0.2) mm, {Sigma}{sub residual}= (1.0, 1.0,0.7) mm, and {sigma}{sub residual}= (2.5, 2.3, 1.8) mm. Intrafraction prostate motion, evaluated using electromagnetic transponders, was: {mu}{sub intrafxn}= (0.0, 0.0, 0.0) mm, {Sigma}{sub intrafxn}= (1.3, 1.5, 0.6) mm, and {sigma}{sub intrafxn}= (2.6, 2.4, 1.4) mm. Shifts between pre- and post-treatment kV images were: {mu}{sub kV(post-pre)}= (-0.3, 0.8, -0.2), {Sigma}{sub kV(post-pre)}= (2.4, 2.7, 2.1) mm, and {sigma}{sub kV(post-pre)}= (2.7, 3.2, 3.1) mm. Relative to skin tattoos, planning margins for setup error were within 10-11 mm for all image-based modalities. The use of image guidance was shown to reduce these margins to less than 5 mm. Margins to compensate for both residual setup (interfraction) errors as well as intrafraction motion were 6.6, 6.8, and 3.9 mm in the A/P, S/I, and L/R directions, respectively. Conclusions: Analysis of interfraction setup errors, performed with US, CBCT, planar kV images, and electromagnetic transponders, from a large dataset revealed intermodality shifts were comparable (within 3-4 mm). Interfraction planning margins, relative to setup based on skin marks, were generally within the 10 mm prostate-to-planning target volume margin used in our clinic. With image guidance, interfraction residual planning margins were reduced to approximately less than 4 mm. These findings are potentially important for dose escalation studies using smaller margins to better protect normal tissues.

60 APPLIED LIFE SCIENCES↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Implementation of dual-energy technique for virtual monochromatic and linearly mixed CBCTs

Purpose: To implement dual-energy imaging technique for virtual monochromatic (VM) and linearly mixed (LM) cone beam CTs (CBCTs) and to demonstrate their potential applications in metal artifact reduction and contrast enhancement in image-guided radiation therapy (IGRT). Methods: A bench-top CBCT system was used to acquire 80 kVp and 150 kVp projections, with an additional 0.8 mm tin filtration. To implement the VM technique, these projections were first decomposed into acrylic and aluminum basis material projections to synthesize VM projections, which were then used to reconstruct VM CBCTs. The effect of VM CBCT on the metal artifact reduction was evaluated with an in-house titanium-BB phantom. The optimal VM energy to maximize contrast-to-noise ratio (CNR) for iodine contrast and minimize beam hardening in VM CBCT was determined using a water phantom containing two iodine concentrations. The LM technique was implemented by linearly combining the low-energy (80 kVp) and high-energy (150 kVp) CBCTs. The dose partitioning between low-energy and high-energy CBCTs was varied (20%, 40%, 60%, and 80% for low-energy) while keeping total dose approximately equal to single-energy CBCTs, measured using an ion chamber. Noise levels and CNRs for four tissue types were investigated for dual-energy LM CBCTs in comparison with single-energy CBCTs at 80, 100, 125, and 150 kVp. Results: The VM technique showed substantial reduction of metal artifacts at 100 keV with a 40% reduction in the background standard deviation compared to a 125 kVp single-energy scan of equal dose. The VM energy to maximize CNR for both iodine concentrations and minimize beam hardening in the metal-free object was 50 keV and 60 keV, respectively. The difference of average noise levels measured in the phantom background was 1.2% between dual-energy LM CBCTs and equivalent-dose single-energy CBCTs. CNR values in the LM CBCTs of any dose partitioning are better than those of 150 kVp single-energy CBCTs. The average CNR for four tissue types with 80% dose fraction at low-energy showed 9.0% and 4.1% improvement relative to 100 kVp and 125 kVp single-energy CBCTs, respectively. CNRs for low-contrast objects improved as dose partitioning was more heavily weighted toward low-energy (80 kVp) for LM CBCTs. Conclusions: Dual-energy CBCT imaging techniques were implemented to synthesize VM CBCT and LM CBCTs. VM CBCT was effective at achieving metal artifact reduction. Depending on the dose-partitioning scheme, LM CBCT demonstrated the potential to improve CNR for low contrast objects compared to single-energy CBCT acquired with equivalent dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Feasibility study of a synchronized-moving-grid (SMOG) system to improve image quality in cone-beam computed tomography (CBCT)

Purpose: To evaluate the feasibility of a synchronized moving grid (SMOG) system to remove scatter artifacts, improve the contrast-to-noise ratio (CNR), and reduce image lag artifacts in cone-beam CT (CBCT). Methods: The SMOG system proposed here uses a rapidly oscillating, synchronized moving grid attached to the kV source. Multiple partial projections are taken at different grid positions to form a complete projection in each gantry position, before the gantry moves to the next position during a scan. The grid has a low transmission factor, and it is used for both scatter reduction and scatter measurement for postscan scatter correction. Experimental studies using a static grid and an enlarged CATphan phantom were performed to evaluate the potential CNR enhancement for different SMOG exposure numbers (1, 2, and 4). Simulation studies were performed to evaluate the image lag correction for different exposure numbers (2, 3, and 4) and grid interspace widths in SMOG using the data from an anthropomorphic pelvis phantom scan. Imaging dose of SMOG was also estimated by measuring the imaging dose in a CIRS CT dose phantom using a static grid. Results: SMOG can enhance the CNR by 16% and 13% when increasing exposure number from 1 to 2 and from 2 to 4, respectively. This enhancement was more dramatic for larger phantoms and smaller initial exposure numbers. Simulation results indicated that SMOG could reduce the lag to less than 4.3% for 2-exposure mode and to less than 0.8% for 3-exposure mode when the grid interspace width was 1.4 cm. Increasing the number of exposures in SMOG dramatically reduced the residual lag in the image. Reducing the grid interspace width somewhat reduced the residual lag. Skin line artifacts were removed entirely in SMOG. Point dose measurement showed that imaging dose of SMOG at isocenter was similar as that of a conventional CBCT. Conclusions: Compared to our previously developed static-grid dual-rotation method, the proposed SMOG technique has the advantages of enhancing the CNR, correcting the image lag, and reducing the delivery time. Once implemented, SMOG has the potential to remove scatter and image lag artifacts, and significantly enhance CNR for CBCT using the same scanning time as conventional CBCT.

60 APPLIED LIFE SCIENCES↗

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 deg. DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 deg. projections was 3.4%. The reconstructed PSNR for the 60 deg. DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 deg. projections was able to reconstruct the 8.1 deg. rotation of the bony structure with 0.0 deg. error. The reconstructed PSNR for the 60 deg. DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 deg. projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic registration between reference and on-board digital tomosynthesis images for positioning verification

The authors developed a hybrid multiresolution rigid-body registration technique to automatically register reference digital tomosynthesis (DTS) images with on-board DTS images to guide patient positioning in radiation therapy. This hybrid registration technique uses a faster but less accurate static method to achieve an initial registration, followed by a slower but more accurate adaptive method to fine tune the registration. A multiresolution scheme is employed in the registration to further improve the registration accuracy, robustness, and efficiency. Normalized mutual information is selected as the criterion for the similarity measure and the downhill simplex method is used as the search engine. This technique was tested using image data both from an anthropomorphic chest phantom and from eight head-and-neck cancer patients. The effects of the scan angle and the region-of-interest (ROI) size on the registration accuracy and robustness were investigated. The necessity of using the adaptive registration method in the hybrid technique was validated by comparing the results of the static method and the hybrid method. With a 44 deg. scan angle and a large ROI covering the entire DTS volume, the average of the registration capture ranges in single-axis simulations was between -31 and +34 deg. for rotations and between -89 and +78 mm for translations in the phantom study, and between -38 and +38 deg. for rotations and between -58 and +65 mm for translations in the patient study. Decreasing the DTS scan angle from 44 deg. to 22 deg. mainly degraded the registration accuracy and robustness for the out-of-plane rotations. Decreasing the ROI size from the entire DTS volume to the volume surrounding the spinal cord reduced the capture ranges to between -23 and +18 deg. for rotations and between -33 and +43 mm for translations in the phantom study, and between -18 and +25 deg. for rotations and between -35 and +39 mm for translations in the patient study. Results also showed that the hybrid registration technique had much larger capture ranges than the static method alone in registering the out-of-plane rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware

The successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm. Reference images are DTS image sets reconstructed from digitally reconstructed radiographs (DRRs) previously generated from conventional planning CT data. Generating a set of DRRs from planning CT is relatively slow using the conventional ray-casting algorithm. In order to facilitate DTS reconstruction within a clinically acceptable period of time, we implemented a high performance DRR reconstruction algorithm on a graphics processing unit of commercial PC graphics hardware. The performance of this new algorithm was evaluated and compared with that which is achieved using the conventional software-based ray-casting algorithm. DTS images were reconstructed from DRRs previously generated by both hardware and software algorithms. On average, the DRR reconstruction efficiency using the hardware method is improved by a factor of 67 over the software method. The image quality of the DRRs was comparable to those generated using the software-based ray-casting algorithm. Accelerated DRR reconstruction significantly reduces the overall time required to produce a set of reference DTS images from planning CT and makes this technique clinically practical for target localization for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗