Search NASA⌕ Search

Engineering topics

Gordley, L. L.

Publications and source records attributed to Gordley, L. L..

27 records · Page 2

The variability of stratospheric nitrogen compounds observed by LIMS in the winter of 1978-1979

The LIMS experiment was launched on the Nimbus 7 satellite for the purpose of sounding the vertical structure of temperature and key upper atmosphere trace gases on a global scale. The technique of thermal infrared limb sounding was used to obtain measurements of O3, H2O, NO2, and HNO3. LIMS collected data almost continuously from late October to late May over the latitude range from 64 deg S to 84 deg N. Two of the gases, NO2 and HNO3, are important elements in the NO(x) chain of chemical reactions leading to ozone destruction. Results for these gases are described in terms of zonal mean profiles and latitudinal distributions. The period selected for study is January-May 1979, when a major stratospheric warming occurred.

Russell, J. M., III↗

Rapid inversion of limb radiance data using an emissivity growth approximation

The time-consuming nature of limb relaxation-type inversion algorithms is due primarily to the numerous integrations over an absorption band to obtain forward radiance values with which to compare measured values. A new method has been devised for the quick and accurate (0.5% error) calculation of single gas broadband (approximately 100 per cm) limb radiance. The method uses a precalculated data base consisting of homogeneous path emissivity vs mass path data for a wide range of temperature and pressure. A 50-km altitude range, 1-km resolution, constituent inversion employing this method requires under 1 sec of computational time when run on modern computer hardware. The method does not rely upon a priori statistical knowledge.

Gordley, L. L.↗

Satellite observations of upper atmosphere O3 and HNO3 from the Limb Infrared Monitor of the Stratosphere /LIMS/ experiment on Nimbus 7

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment, launched on-board the Nimbus satellite, was designed to measure both day and night limb radiance which is used to infer upper atmosphere temperature profiles and chemical compound concentrations important in the study of ozone chemistry. The LIMS instrument is a six channel, limb scanning, thermal radiometer which uses HgCdTe detectors, cooled to approximately 64 K. Measurements include ozone, water vapor, nitrogen dioxide, and nitric acid. The ozone and nitric acid channels are centered at approximately 9.6 microns and 11.3 microns, respectively. Results from the channels are described with an emphasis on data validation. The O3 and HNO3 channels have demonstrated high measurement precision.

Russell, J. M., III↗

The validation of LIMS ozone profiles using correlative rocket, ECC, and Dobson data sets

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment is a limb scanning infrared sounder designed to measure vertical temperature profiles and the concentrations of key chemical compounds which are important in the stratospheric ozone-nitrogen photochemistry. Preliminary ozone profiles are being intercompared with correlative rocket and balloonsonde ozone data sets as part of the Nimbus 7 LIMS data validation activity. The LIMS ozone retrievals extend from the lower mesosphere to the tropopause (or cloud-top altitudes). In this paper, preliminary statistics of comparisons of ECC (electrochemical concentration cell) ozonesonde and rocket ozone profiles with LIMS ozone profiles are presented. ECC ozonesonde data taken at times of LIMS overpasses are also used to extend the LIMS retrieval down to ground level. Each combined profile is then integrated to obtain total column ozone. These integrated results are compared to Dobson data obtained at approximately the same time and location.

Remsberg, E. E.↗

Stratospheric water vapor results from the limb infrared monitor of the stratosphere /LIMS/ experiment on Nimbus 7

Stratospheric water vapor results taken from the limb infrared monitor of the stratosphere experiment on Nimbus 7 are presented with emphasis on validation studies. Basic radiance data, the indicated orbital precision of the experiment and comparisons made with data collected in simultaneous balloon underflights are described. A plot of pressure versus H2O channel radiance shows the radiance variability as a function of pressure and latitude. Measured precision is in good agreement with calculated values using simulations.

Russell, J. M., III↗

A fast and accurate radiance algorithm for application to inversion of limb measurements

A method is devised to accurately calculate broad band limb radiance based on a precalculated data base consisting of homogeneous path emissivity as a function of mass path data for various temperatures and pressures. Accurately estimating limb radiance by splicing together interpolated information from the emissivity curves requires no temperature or pressure weighting, and only two interpolations per layer path. The emissivity growth approximation (EGA) technique is applied in a simulated inversion study to the inference of O3, H2O, NO2 and HNO3, and it is found to have comparable accuracies to more sophisticated many-degree band models. The EGA technique is also found to be two orders of magnitude faster, while requiring one second per inversion for one constituent at one-km resolution, allowing a completely nonlinear relaxation time inversion to be done at linear speeds. The technique is also expected to work well for nadir calculations, and prove adequate for estimating occultation radiances.

Gordley, L. L.↗

The simultaneous inference of stratospheric NO2-H2O and HNO3-CF2Cl2 using limb sounding radiometry

An inversion algorithm has been developed to simultaneously infer the concentrations of two gases with overlapping spectral signatures using limb emission measurements. The algorithm provides a solution in two or three iterations and has been tested in a simulation study for the inference of stratospheric NO2-H2O and HNO3-CF2Cl2. Existing satellite instrumentation was the basis for errors used in the calculations. These included noise, scale and bias errors, angular registration errors, spacecraft motion effects, and effects due to a finite instrument field of view. It is estimated that concentrations of all four gases can be measured globally from a satellite with errors of less than 20%.

Russell, J. M., III↗

Analysis of differential absorption lidar from the Space Shuttle

A parametric analysis of the Shuttle-borne differential absorption lidar concept for the measurement of atmospheric trace constituent profiles in the nadir viewing mode is presented. The criterion of an optimum constituent optical depth is developed and applied to generate estimates of range resolved measurement errors. These errors emphasize the fundamental limitations for establishing the feasibility of range-resolved differential absorption lidar measurements from Shuttle. With current lidar system technology, atmospheric backscatter density profiles may be adequately determined up to about 60-km altitude at the doubled-ruby wavelength, 3472 A, for a 1-J/pulse laser and a 1-sq m receiver. Potential range-resolved measurements of stratospheric and mesospheric trace constituents by differential absorption from Shuttle altitudes are limited to H2O, CH4, N2O, O3, and CO, species which can be more easily measured by passive limb viewing techniques. Range-resolved water vapor data for the lower troposphere may be obtained with accuracies which would be competitive with those from passive sensors.

Remsberg, E. E.↗

The simultaneous inference of stratospheric trace gases with overlapping spectral signatures using limb sounding radiometry

An inversion algorithm has been developed to simultaneously infer the concentrations of two gases with overlapping spectral signatures using limb emission measurements. The algorithm is efficient and provides a solution in two or three iterations. It has been applied in a simulation study to the inference of stratospheric NO2-H2O and HNO3-CF2Cl2. Existing satellite instrumentation was the basis for errors used in the calculations. It is estimated that concentrations of all four gases can be determined with errors of about 20 percent. This assumes an estimated 1980 CF2Cl2 level. Also, other error sources due to contaminant gas, aerosol emission, and the temperature profile must be included to obtain a better estimate of experimental accuracies.

Russell, J. M., III↗