Reference Cell Performance and Modeling on a One-Axis Tracking Surface: Preprint

Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.

modeling↗

Evaluation of Solar Reference Cells on a Two-Axis Tracker Using Spectral Measurements

A simple model calculating the performance of an IMT solar reference cell is proposed and tested under clear sky periods. One-minute data from EKO spectroradiometers collocated with an IMT reference cell are used for the analysis. Data are obtained at the NREL Solar Radiation Research Laboratory in Golden, Colorado and the UO Solar Radiation Monitoring Laboratory in Eugene, Oregon. The model is also applied and evaluated under cloudy conditions. A match of better than 1% is found between calculated clear sky values and IMT measurements for July, 2020. One- minute cloudy sky comparisons show a much larger variation, but when averaged over one hour, a standard deviation of 4% between the calculated and measured values is found.

atmospheric radiation↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Solar Radiation Research Laboratory (SRRL) Final Report: Fiscal Years 2019-2021

The Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m 2 ) for the United States, which is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two International Organization for Standardization (ISO)/International Electrotechincal Commission (IEC) 17025 calibration facilities that provide unique, high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop: improved methods for the calibration of solar radiometers; new standards through the ISO, the IEC, and ASTM International; models; advanced instrumentation and methods for operating solar measurement stations. The SRRL data sets are also critical for the validation of new models and data sets, such as the National Solar Radiation Database (NSRDB).

14 SOLAR ENERGY↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Grobner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Grobner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

47 OTHER INSTRUMENTATION↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Gröbner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Gröbner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Improved field evaluation of reference cells using spectral measurements

Output from an IMT reference solar cell mounted on a one-axis tracking surface is investigated using spectral measurements covering the 350–1650 nm range for selected days throughout the year. Comparisons are made to a Class-A pyranometer also mounted on the one-axis tracking surface. Systematic biases over the day and year are observed in the ratio of the reference cell’s measurements to reference pyranometer measurements. This systematic bias is associated with the spectral, temperature, and angle-of-incident effects that differ between the reference cell and the reference pyranometer. The comparison is done for selected clear and totally cloudy days to determine the magnitude of the effects and to characterize the influence of these effects on the reference cell measurements. A model to calculate the reference cell output based on spectral irradiance and reference cell temperature is introduced.

14 SOLAR ENERGY↗

Using Spectral Measurements to Characterize Solar Reference Cells on a Two-Axis Tracker

A study is commencing relating the spectral responsivity of reference cells in the field to changing spectral distribution during the day. Initial results indicate that measurements of the incident spectral distribution can be used to match results of reference cell measurements on a two-axis tracker with a standard deviation of ±0.25% under clear-sky conditions. Initial results are provided. As more data are obtained covering a variety of field conditions and locations, the robustness of these results will be tested. The website https://midcdmz.nrel.gov/apps/sitehome.pl?site=PVRES contains the data generated by this project.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Annual Solar Irradiance Anomaly Features Over the USA During 1998-2017 Using NSRDB V3

Annual solar irradiance anomalies (or departures from the long-term mean annual value) have a direct impact on various phases of solar energy projects, from prefeasibility studies to technical deployment decisions. Anomalies can happen because of normal climate variability or exceptional weather patterns. This study investigates such anomalies for both global horizontal irradiance (GHI) and direct normal irradiance (DNI) using Version 3 of the National Solar Radiation Database (NSRDB V3) and surface irradiance measurements at eight U.S. locations. At each site, the annual anomaly is analyzed here by evaluating the irradiance deviation from the long-term average for each specific year from 1998–2017. A positive/negative anomaly indicates that the solar resource was higher/lower than the long-term average during that specific year. The results show that in most cases the anomaly is within ±5% for GHI and ±10% for DNI using either ground-based irradiance measurements or modeled data from the NSRDB.

41 EE - Solar Energy Technologies Office (EE-4S)↗

NREL Pyrheliometer Comparisons: September 23-October 4, 2019 (NPC-2019)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG.

14 SOLAR ENERGY↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

Annual Solar Irradiance Anomaly Features Over the USA During 1998-2017 Using NSRDB V3: Preprint

Annual solar irradiance anomalies (or departures from the long-term mean annual value) have a direct effect on various phases of solar energy projects, from prefeasibility to deploy-ment. Anomalies can happen because of normal climate varia-bility or exceptional weather patterns. This study investigates such anomalies for both global horizontal irradiance (GHI) and direct normal irradiance (DNI) using Version 3 of the National Solar Radiation Database (NSRDB V3) and surface irradiance measurements at eight U.S. locations. At each site, the annual anomaly is analyzed here by evaluating the irradi-ance deviation from the long-term average for each specific year during 1998–2017. A positive anomaly indicates that the solar resource was higher than the long-term average during that specific year, and vice versa in the case of a negative anomaly. The results show that, in most cases, the anomaly is within ±5% for GHI and ±10% for DNI, using either ground-based irradiance measurements or modeled data from the NSRDB.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.