Search NASA⌕ Search

Engineering topics

Gupta, S. K.

Publications and source records attributed to Gupta, S. K..

At least 19 records

Global Climate

The 2019 global lower tropospheric temperature (LTT), which encompasses the atmosphere from the surface to ~10 km, ranked second warmest in seven datasets and first or third in the remaining two (Fig. 2.7). These records extend back to 1958 using radiosonde (balloon-borne instrumentation) data and one reanalysis dataset (JRA55), which demonstrate reasonable agreement with the 40+ year satellite record (since late 1978) and two other reanalysis datasets (since 1979 and 1980, ERA5 and MERRA2, respectively). Aweak El Niño contributed to increased global temperatures as 2019 values were +0.44° to +0.68°C higher than the 1981–2010 average (depending on the dataset), being just slightly cooler (~0.07°C on average) than the record warm year of 2016. At least fourof the five globally complete datasets (ERA5, MERRA2, JRA55, RSS, UAH) recorded each of the four months—June, September, November, and December—as experiencing their warmest monthly global LTT.

58 GEOSCIENCES↗

Chemical synthesis and characterization of PdTe-Ag{sub 2}Te nanowires heterostructure

Ag{sub 2}Te and Pd doped Ag{sub 2}Te nanowires are synthesized using chemical route. Field Emission Scanning Electron Microscopy (FESEM) shows the presence of nanowires of nearly few micron length and ~ 200 nm diameter. The composition analysis performed using Electron Dispersive Spectroscopy (EDS) shows the presence of almost 1.98 at% palladium. Reitveld refinement of X-ray diffraction (XRD) shows the presence of 0.3 % of PdTe phase in addition to Ag{sub 2}Te in Pd doped Ag{sub 2}Te sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Attempts to improve the H{sub 2}S sensitivity of TiO{sub 2} films

We report the pulsed laser deposited titanium oxide thin film for H{sub 2}S gas sensing. The surface and bulk electronic structure is revealed using XPS technique. These TiO{sub 2} films showed very good selectivity to H{sub 2}S with response of around ~ 60% at 200°C operating temperature. In order to improve the sensor response so as to realize the technological application, we hereby attempted bi-directional efforts as (i) Nb-doping and (ii) defects engineering in the TiO{sub 2} film. It is revealed that Nb-doping reduces response however defect engineering improves the same.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement in thermoelectric power factor of mechanically alloyed p-type SiGe by incorporation of TiB{sub 2}

Nearly 60% of the world’s useful energy is wasted as heat and recovering a fraction of this waste heat by converting it as useful electrical power is an important area of research{sup [1]}. Thermoelectric power generators (TEG) are solid state devices which converts heat into electricity. TEG consists of n and p-type thermoelements connected electrically in series and thermally in parallel{sup [2]}. Silicon germanium (SiGe) alloy is one of the conventional high temperature thermoelectric materials and is being used in radio-isotopes based thermoelectric power generators for deep space exploration programs.Temperature (T) dependence of thermoelectric (TE) properties of p-type SiGe and p-type SiGe-x wt.%TiB{sub 2} (x=6,8,10%) nanocomposite materials has been studied with in the temperature range of 300 K to 1100 K. It is observed that there is an improvement in the power factor (α{sup 2}/ρ) of SiGe alloy on addition of TiB{sub 2} upto 8 wt.% that is mainly due to increase in the Seebeck coefficient (α) and electrical conductivity (σ) of the alloy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of thermal stability of Cu{sub 2}Se thermoelectric material

Sustainability of thermoelectric parameter in operating temperature range is a key consideration factor for fabricating thermoelectric generator or cooler. In present work, we have studied the stability of thermoelectric parameter of Cu{sub 2}Se within the temperature range of 50-800°C. Temperature dependent Seebeck coefficients and electrical resistivity measurement are performed under three continuous thermal cycles. X-ray diffraction pattern shows the presence of mixed cubic-monoclinic Cu{sub 2}Se phase in bare pellet which transforms to pure α-Cu{sub 2}Se phase with repeating thermal cycle. Significant enhancement in Seebeck coefficient and electrical resistivity is observed which may be attributed to (i) Se loss observed in EDS and (ii) the phase transformation from mixed cubic-monoclinic structure to pure monoclinic α-Cu{sub 2}Se phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ab-initio study of oxygen defects in pure ThO{sub 2}

First principles calculations using projector augmented wave potentials and generalized gradient approximations predicts the structural relaxations due to neutral and positively charged oxygen defects (+1 and +2) in bulk thoria leads to symmetric distortion around the vacancy site. Electronic Density of states (DOS) analysis shows presence of defects states mainly contributed by Th d and f states near the conduction band minima for the double positively charged oxygen vacancy which is having lowest energy of formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-channel programmable power supply with temperature compensation for silicon sensors

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WO{sub 3} thin film based multiple sensor array for electronic nose application

Multiple sensor array comprising 16 x 2 sensing elements were realized using RF sputtered WO{sub 3} thin films. The sensor films were modified with a thin layer of sensitizers namely Au, Ni, Cu, Al, Pd, Ti, Pt. The resulting sensor array were tested for their response towards different gases namely H{sub 2}S, NH{sub 3}, NO and C{sub 2}H{sub 5}OH. The sensor response values measured from the response curves indicates that the sensor array generates a unique signature pattern (bar chart) for the gases. The sensor response values can be used to get both qualitative and quantitative information about the gas.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of swift Li{sup 3+} ions irradiation on magnetic properties of Ce(Fe{sub 0.95}Si{sub 0.05}){sub 2}

Magnetic field induced Anti-ferromagnetic (AFM) to ferromagnetic (FM) phase transition on a sample of Ce(Fe{sub 0.95}Si{sub 0.05}){sub 2} is studied before and after swift Li{sup 3+} ions irradiation. Presence of irradiation induced material defects caused the AFM-FM transition to move to lower fields, increased the zero field magnetic susceptibility in AFM region and decreased the logarithmic relaxation rate in the hysteretic transition region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the Abundance of Radioactive Be-10 and Other Light Isotopes in Cosmic Radiation Up to 2 GeV /Nucleon with the Balloon-Borne Instrument Isomax

The Isotope Magnet Experiment (ISOMAX), a balloon-borne superconducting magnet spectrometer, was designed to measure the isotopic composition of the light isotopes (3 les than or = Z less than or = 8) of cosmic radiation up to 4 GeV/nucleon with a mass resolution of better than 0.25 amu by using the velocity versus rigidity technique. To achieve this stringent mass resolution, ISOMAX was composed of three major detector systems: a magnetic rigidity spectrometer with a precision drift chamber tracker in conjunction with a three-layer time-of-flight system, and two silica-aerogel Cerenkov counters for velocity determination. A special emphasis of the ISOMAX program was the accurate measurement of radioactive Be-10 with respect to its stable neighbor isotope Be-9, which provides important constraints on the age of cosmic rays in the Galaxy. ISOMAX had its first balloon flight on 1998 August 4-5 from Lynn Lake, Manitoba, Canada. Thirteen hours of data were recorded during this flight at a residual atmosphere of less than 5 g/sq cm. The isotopic ratio at the top of the atmosphere for Be-10/Be-9 was measured to be 0.195 +/- 0.036 (statistical) +/- 0.039 (systematic) between 0.26 and 1.03 GeV/nucleon and 0.317 +/- 0.109(statistical) +/- 0.042(systematic) between 1.13 and 2.03 GeV/nucleon. This is the first measurement of its kind above l GeV/nucleon. ISOMAX results tend to be higher than predictions from current propagation models. In addition to the beryllium results, we report the isotopic ratios of neighboring lithium and boron in the energy range of the time-of-flight system (up to approx. 1 GeV/nucleon). The lithium and boron ratios agree well with existing data and model predictions at similar energies.

Hams, T.↗

Abundance of the Radioactive Be-10 in the Cosmic Radiation up to 2 GeVnucleon-l with the Balloon-borne Instrument ISOMAX1998

The Isotope Magnet Experiment (ISOMAX) a balloon-borne superconducting magnet spectrometer was designed to measure the isotopic composition of the light isotopes (3 less than or equal to Z less than or equal to 8) of the cosmic radiation up to 4 GeV nucleon (exp -1) with a mass resolution of better than 0.25 amu by using the velocity vs. rigidity technique. To achieve this stringent mass resolution ISOMAX was comprised of three major detector systems, a magnetic rigidity spectrometer with a precision drift chamber tracker in conjunction with a three-layer time-of-flight system and two silica-aerogel Cherenkov counters for the velocity determination. A special emphasis of the ISOMAX program was the accurate measurement of radioactive Be-10 with respect to its stable neighbor isotope Be-9, which provides important constraints on the age of cosmic rays in the Galaxy. ISOMAX had its first balloon flight on August 4-5, 1998, from Lynn Lake, Manitoba, Canada. Thirteen hours of data were recorded during this flight at a residual atmosphere of less than 5 g per square centimeter. The isotopic ratio at the top of the atmosphere for Be-10/Be-9 was measured to be 0.195 plus or minus 0.036 (statistical) plus or minus 0.039 (systematic) between 0.26 - 1.03GeV nucleon (exp -1) and 0.317 plus or minus 0.109 (statistical) plus or minus 0.042 (systematic) between 1.13 - 2.03GeV nucleon(exp -1). This is the first measurement of its kind above 1 GeV nucleon (exp -1). ISOMAX results tend to be higher than predictions from current propagation models.

Hams, T.↗

The WCRP/GEWEX Surface Radiation Budget Project Release 2: An Assessment of Surface Fluxes at 1 Degree Resolution

The U.S. National Aeronautics and Space Administration (NASA) based Surface Radiation Budget (SRB) Project in association with the World Climate Research Programme Global Energy and Water Cycle Experiment (WCRP/GEWEX) is preparing a new 1 deg x 1 deg horizontal resolution product for distribution scheduled for release in early 2001. The new release contains several significant upgrades from the previous version. This paper summarizes the most significant upgrades and presents validation results as an assessment of the new data set.

Stackhouse, P. W., Jr.↗

Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth's Radiant Energy System Instrument on the Tropical Rainfall Measuring Mission Satellite: Methodology - Part 1

Clouds and the Earth s Radiant Energy System (CERES) investigates the critical role that clouds and aerosols play in modulating the radiative energy flow within the Earth-atmosphere system. CERES builds upon the foundation laid by previous missions, such as the Earth Radiation Budget Experiment, to provide highly accurate top-of-atmosphere (TOA) radiative fluxes together with coincident cloud and aerosol properties inferred from high-resolution imager measurements. This paper describes the method used to construct empirical angular distribution models (ADMs) for estimating shortwave, longwave, and window TOA radiative fluxes from CERES radiance measurements on board the Tropical Rainfall Measuring Mission satellite. To construct the ADMs, multiangle CERES measurements are combined with coincident high-resolution Visible Infrared Scanner measurements and meteorological parameters from the European Centre for Medium-Range Weather Forecasts data assimilation product. The ADMs are stratified by scene types defined by parameters that have a strong influence on the angular dependence of Earth's radiation field at the TOA. Examples of how the new CERES ADMs depend upon the imager-based parameters are provided together with comparisons with existing models.

Loeb, N. G.↗

Longwave surface radiation over the globe from satellite data - An error analysis

Errors have been analyzed for monthly-average downward and net longwave surface fluxes derived on a 5-deg equal-area grid over the globe, using a satellite technique. Meteorological data used in this technique are available from the TIROS Operational Vertical Sounder (TOVS) system flown aboard NOAA's operational sun-synchronous satellites. The data used are for February 1982 from NOAA-6 and NOAA-7 satellites. The errors in the parametrized equations were estimated by comparing their results with those from a detailed radiative transfer model. The errors in the TOVS-derived surface temperature, water vapor burden, and cloud cover were estimated by comparing these meteorological parameters with independent measurements obtained from other satellite sources. Analysis of the overall errors shows that the present technique could lead to underestimation of downward fluxes by 5 to 15 W/sq m and net fluxes by 4 to 12 W/sq m.

Gupta, S. K.↗

ERBE and AVHRR Cirrus cloud fire study

Understanding the impact of cirrus clouds on the global radiation budget is essential to determining the role of clouds in the process of climate change. The ongoing Earth Radiation Budget Experiment (ERBE) is charged with measuring the global radiation balance at the top of the atmosphere. The International Satellite Cloud Climatology Project (ISCCP) is measuring global cloud amounts and properties over a time frame similar to ERBE. Specific cloud properties are absent from the ERBE program, while ISCCP lacks the broadband radiances necessary to determine the total radiation fields. Together, results from these two global programs have the potential for improving the knowledge of the relationship between cirrus clouds and the Earth radiation balance. The First ISCCP Regional Experiment (FIRE), especially its cirrus Intensive Field Observations (IFO), provides opportunities for studying radiation measurements from the ERBE taken over areas with known cirrus cloud properties. Satellite measurements taken during the IFO are used to determine the broadband radiation fields over cirrus clouds and to examine the relationship between narrowband and broadband radiances over various known scenes. The latter constitutes the link between the ERBE and the ISCCP.

Harrison, Edwin F.↗

Downward longwave surface radiation from sun-synchronous satellite data - Validation of methodology

An extensive study has been carried out to validate a satellite technique for estimating downward longwave radiation at the surface. The technique, mostly developed earlier, uses operational sun-synchronous satellite data and a radiative transfer model to provide the surface flux estimates. The satellite-derived fluxes were compared directly with corresponding ground-measured fluxes at four different sites in the United States for a common one-year period. This provided a study of seasonal variations as well as a diversity of meteorological conditions. Dome heating errors in the ground-measured fluxes were also investigated and were corrected prior to the comparisons. Comparison of the monthly averaged fluxes from the satellite and ground sources for all four sites for the entire year showed a correlation coefficient of 0.98 and a standard error of estimate of 10 W/sq m. A brief description of the technique is provided, and the results validating the technique are presented.

Darnell, W. L.↗

Microburst of TeV gamma rays from the Crab pulsar

Data on Crab pulsar from atmospheric Cerenkov array at Ooty have shown emission of TeV gamma rays in the form of microbursts. These are a series of events which are unusually closely spaced in time with time separations of less than 1.5 milliseconds. The phasogram of events in the bursts when analyzed with the Crab pulsar period shows significant peaks. Data further show that the signal is at the same absolute phase as the radio peak. Monte Carlo calculations show that the probability of peaks being due to chance is very small.

Vishwanath, P. R.↗

Secondary periodicities of microbursts of TeV gamma rays from the Crab pulsar

Observations were made during the past several years on the Crab pulsar using the Ooty atmospheric Cerenkov array with the aim of detecting possible emission of ultra high energy gamma rays by the pulsar. During the course of these observations, it was found that the Crab pulsar emits TeV gamma rays in bursts of short duration. The microbursts of TeV gamma rays from the Crab pulsar, which were seen in the data of at least three years, also reveal interesting secondary periodicities. It was noticed at first that some bursts could be connected with the others that occurred during the same night or during the next two nights with integral number of cycles of periods 43 + or - 1 minute. Ten possible periods in the vicinity of 43 minutes were determined for all the combinations of bursts for each year. The best values of periods thus obtained were different from year to year. But when, instead of the real time, the number of Crab cycles elapsed between the bursts was used as the unit of time, two values of burst periods - 77460 and 77770 Crab cycles - were found to be significant in the data of at least two years. A Monte Carlo simulation using 1500 trial periods chosen randomly within + or - 5 minutes of the original burst period did not reveal any value of the period as significant.

Vishwanath, P. R.↗