Search NASA⌕ Search

Engineering topics

Hall, R. M.

Publications and source records attributed to Hall, R. M..

At least 37 records · Page 2

Onset of condensation effects in cryogenic wind tunnels

The onset of condensation effects in cryogenic wind tunnels which limits their minimum operating temperatures is examined. If this onset of effects occurs below saturation temperature, then the tunnels may be operated at the lower temperatures and additional benefits to cryogenic tunnel operation resulting in increased Reynolds number capability and reduced operating costs. Both homogeneous and heterogeneous nucleation processes are discussed as they pertain to continuous flow cryogenic wind tunnels. Examples from condensation experiments in the 0.3 m Transonic Cryogenic Tunnel are also reviewed.

Hall, R. M.↗

Simulation of ideal-gas flow by nitrogen and other selected gases at cryogenic temperatures

The real gas behavior of nitrogen, the gas normally used in transonic cryogenic tunnels, is reported for the following flow processes: isentropic expansion, normal shocks, boundary layers, and interactions between shock waves and boundary layers. The only difference in predicted pressure ratio between nitrogen and an ideal gas which may limit the minimum operating temperature of transonic cryogenic wind tunnels occur at total pressures approaching 9 atm and total temperatures 10 K below the corresponding saturation temperature. These pressure differences approach 1 percent for both isentropic expansions and normal shocks. Alternative cryogenic test gases were also analyzed. Differences between air and an ideal diatomic gas are similar in magnitude to those for nitrogen and should present no difficulty. However, differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. It is concluded that helium and cryogenic hydrogen would not approximate the compressible flow of an ideal diatomic gas.

Hall, R. M.↗

Generalization of low pressure, gas-liquid, metastable sound speed to high pressures

A theory is developed for isentropic metastable sound propagation in high pressure gas-liquid mixtures. Without simplification, it also correctly predicts the minimum speed for low pressure air-water measurements where other authors are forced to postulate isothermal propagation. This is accomplished by a mixture heat capacity ratio which automatically adjusts from its single phase values to approximately the isothermal value of unity needed for the minimum speed. Computations are made for the pure components parahydrogen and nitrogen, with emphasis on the latter. With simplifying assumptions, the theory reduces to a well known approximate formula limited to low pressure.

Bursik, J. W.↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Real gas effects 2: Influence of condensation on minimum operating temperatures of cryogenic wind tunnels

Condensation effects are responsible for the minimum operating temperatures of cryogenic wind tunnels at total pressures up to about 9 atmospheres. The two primary modes of condensation homogeneous nucleation and heterogeneous nucleation and the conditions with which either may limit minimum operating temperatures are reveiwed. Previous hypersonic and supersonic condensation data are reviewed as are data taken in the nitrogen gas, Langley 0.3 Meter Transonic Cryogenic Tunnel. Analysis of data in the 0.3 m tunnel suggests that the onset of homogenous nucleation may be approximated by an analysis by sivier and that the onset of heterogeneous nucleation is only apparent just below free stream saturation. Extension of the results from the 0.3 m tunnel to other nitrogen gas cryogenic tunnels is discussed and is shown to depend on length scales, purity of the liquid nitrogen injected for cooling, number of particulates in the flow, and the extent to which the injected liquid nitrogen is evaporated.

Hall, R. M.↗

Effects of various assumptions on the calculated liquid fraction in isentropic saturated equilibrium expansions

The saturated equilibrium expansion approximation for two phase flow often involves ideal-gas and latent-heat assumptions to simplify the solution procedure. This approach is well documented by Wegener and Mack and works best at low pressures where deviations from ideal-gas behavior are small. A thermodynamic expression for liquid mass fraction that is decoupled from the equations of fluid mechanics is used to compare the effects of the various assumptions on nitrogen-gas saturated equilibrium expansion flow starting at 8.81 atm, 2.99 atm, and 0.45 atm, which are conditions representative of transonic cryogenic wind tunnels. For the highest pressure case, the entire set of ideal-gas and latent-heat assumptions are shown to be in error by 62 percent for the values of heat capacity and latent heat. An approximation of the exact, real-gas expression is also developed using a constant, two phase isentropic expansion coefficient which results in an error of only 2 percent for the high pressure case.

Bursik, J. W.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The past 6 years of operation with the NASA Langley 0.3 m transonic cryogenic tunnel (TCT) show that there are no insurmountable problems associated with cryogenic testing with gaseous nitrogen at transonic Mach numbers. The fundamentals of the concept were validated both analytically and experimentally and the 0.3 m TCT, with its unique Reynolds number capability, was used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects were developed and cryogenic tunnel conditions can be set and maintained accurately. Cryogenic cooling by injecting liquid nitrogen directly into the tunnel circuit imposes no problems with temperature distribution or dynamic response characteristics. Experience with the 0.3 m TCT, indicates that there is a significant learning process associated with cryogenic, high Reynolds number testing. Many of the questions have already been answered; however, factors such as tunnel control, run logic, economics, instrumentation, and model technology present many new and challenging problems.

Ray, E. J.↗

A two phase Mach number description of the equilibrium flow of nitrogen in ducts

Some additional thermodynamic properties of the usual two-phase form which is linear in the moisture fraction are derived which are useful in the analysis of many kinds of duct flow. The method used is based on knowledge of the vapor pressure and Gibbs function as functions of temperature. With these, additional two-phase functions linear in moisture fraction are generated, which ultimately reveal that the squared ratio of mixture specific volume to mixture sound speed depends on liquid mass fraction and temperature in the same manner as do many weighted mean two-phase properties. This leads to a simple method of calculating two-phase Mach numbers for various duct flows. The matching of one- and two-phase flows at a saturated vapor point with discontinuous Mach number is also discussed.

Bursik, J. W.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

Onset of condensation effects with an NACA 0012-64 airfoil tested in the Langley 0.3-meter transonic cryogenic tunnel

The onset of condensation effects as determined by varying the stagnation temperature was found to correlate better with the amount of supercooling in the free stream than it did with the supercooling in the region of maximum local Mach number over the air foil. Effects in the pressure distribution over the air foil were seen to appear over its entire length at nearly the same total temperature. Both observations suggest that heterogeneous nucleation does occur in the free stream. The benefits realized from supercooling are presented in terms of increased Reynolds number capability at a given tunnel total pressure and reduced drive-fan power and liquid nitrogen consumption if Reynolds number is held constant. Depending on total pressure and free-stream Mach number, these three benefits are found to vary respectively from 8 to 19 percent, 12 to 24 percent, and 9 to 19 percent. The data analysis and error estimates are given.

Hall, R. M.↗

Full-scale aircraft simulation with cryogenic tunnels and status of the National Transonic Facility

The effect of thermal and caloric imperfections in cryogenic nitrogen on boundary layers was determined to indicate that in order to simulate nonadiabatic laminar or turbulent boundary layers in a cryogenic nitrogen wind tunnel, the flight enthalpy ratio, rather than the temperature ratio, should be reproduced. The absence of significant real gas effects on both viscous and inviscid flows makes it unlikely that there will be large real gas effects on the cryogenic tunnel simulation of shock boundary layer interactions or other complex flow conditions encountered in flight. Condensation effects were studied to determine the minimum usable temperature and indicated that under most circumstances free stream Mach number rather than maximum local Mach number determines the onset of condensation effects.

Kilgore, R. A.↗

Metastable sound speed in gas-liquid mixtures

A new method of calculating speed of sound for two-phase flow is presented. The new equation assumes no phase change during the propagation of an acoustic disturbance and assumes that only the total entropy of the mixture remains constant during the process. The new equation predicts single-phase values for the speed of sound in the limit of all gas or all liquid and agrees with available two-phase, air-water sound speed data. Other expressions used in the two-phase flow literature for calculating two-phase, metastable sound speed are reviewed and discussed. Comparisons are made between the new expression and several of the previous expressions -- most notably a triply isentropic equation as used, a triply isentropic equation as used, among others, by Karplus and by Wallis. Appropriate differences are pointed out and a thermodynamic criterion is derived which must be satisfied in order for the triply isentropic expression to be thermodynamically consistent. This criterion is not satisfied for the cases examined, which included two-phase nitrogen, air-water, two-phase parahydrogen, and steam-water. Consequently, the new equation derived is found to be superior to the other equations reviewed.

Bursik, J. W.↗

A review of at rest droplet growth equations for condensing nitrogen in transonic cryogenic wind tunnels

Droplet growth equations are reviewed in the free-molecular, transition, and continuum flow regimes with the assumption that the droplets are at rest with respect to the vapor. As comparison calculations showed, it was important to use a growth equation designed for the flow regime of interest. Otherwise, a serious over-prediction of droplet growth may result. The growth equation by Gyarmathy appeared to be applicable throughout the flow regimes and involved no iteration. His expression also avoided the uncertainty associated with selecting a mass accommodation coefficient and consequently involved less uncertainty in specifying adjustable parameters than many of the other growth equations.

Hall, R. M.↗

Full scale aircraft simulation with cryogenic tunnels and status of the National Transonic Facility

The paper reviews the results of some of the real-gas studies made at Langley that are directly related to establishing the range of operating conditions that can be used in a cryogenic nitrogen wind tunnel and still be assured of valid full-scale simulation. Consideration is given to the important aerodynamic features, anticipated performance capability, status of construction, and projected operating data for the National Transonic Facility.

Kilgore, R. A.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The fundamentals of cryogenic testing are validated both analytically and experimentally employing the 0.3-m transonic cryogenic tunnel. The tunnel with its unique Reynolds number capability has been used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects have been developed and cryogenic tunnel conditions are set and maintained accurately. It is shown that cryogenic cooling, by injecting nitrogen directly into the tunnel circuit, imposes no problems with temperature distribution or dynamic response characteristics.

Ray, E. J.↗

Onset of condensation effects with a NACA 0012-64 airfoil tested in the Langley 0.3-meter cryogenic tunnel

A 0.137m airfoil was tested in a 0.3m transonic cryogenic tunnel at free stream Mach numbers of 0.75, 0.85, and 0.95 over a total pressure range from 1.2 to 5.0 atmospheres. The onset of condensation effects were found to correlate more with the amount of supercooling in the free stream than it did with the supercooling in the region of maximum local Mach number over the airfoil. Effects in the pressure distribution over the airfoil were generally seen to appear over its entire length at nearly the same total temperature. Both observations suggest the possibility of heterogeneous nucleation occurring in the free stream. The potential operational benefits of the supercooling realized are presented in terms of increased Reynolds number capability at a given tunnel total pressure, reduced drive fan power if Reynolds number is held constant, and reduced liquid nitrogen consumption if Reynolds number is again constant. Depending on total pressure and free stream Mach number, these three benefits are found to respectively vary from 7 to 19%, 11 to 25%, and 9 to 20%.

Hall, R. M.↗

Condensation and its growth down the test-section of the Langley 0.3-m transonic cryogenic tunnel

Four total pressure probes were used to measure the growth of condensation down the test section of the Langley 0.3-m tunnel, and the condensation data were employed to verify a mathematical model which assumes condensation results from heterogeneous nucleation on preexisting seed particles. The onset of effects occurs throughout the test section at the same total temperature but the magnitude of the effects increases with increasing length down the test section. Condensation is important because it determines the minimum operating temperature of transonic cryogenic wind tunnels.

Hall, R. M.↗

An analysis of data related to the minimum temperatures for valid testing in cryogenic wind tunnels using nitrogen as the test gas

The minimum operating temperature which avoids adverse low temperature effects, such as condensation, has been determined at a free stream Mach number of 0.85 for flow over a 0.137 meter airfoil mounted at zero incidence in the Langley 1/3 meter transonic cryogenic tunnel. The onset of low temperature effects is established by comparing the pressure coefficient measured at a given orifice for a particular temperature with those measured at temperatures sufficiently above where low temperature effects might be expected to occur. The pressure distributions over the airfoil are presented in tabular form. In addition, the comparisons of the pressure coefficient as a function of total temperature are presented graphically for chord locations of 0, 25, 50, and 75 percent. Over the 1.2 to 4.5 atmosphere total pressure range investigated, low temperature effects are not detected until total temperatures are 2 K, or more, below free stream saturation temperatures.

Hall, R. M.↗