Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Vapor detection and vapor pressure measurements of fentanyl and fentanyl hydrochloride salt at ambient temperatures

There is a need for non-contact, real-time vapor detection of drugs to combat illicit transportation and help curb the opioid epidemic. The low-volatility of drugs, like fentanyl, makes room temperature vapor detection of illicit drugs challenging, but feasible by atmospheric flow tube-mass spectrometry (AFT-MS). AFT-MS is a non-contact vapor detection approach capable of ultra-trace detection of drugs, including fentanyl and its analogs at low parts-per-quadrillion (ppqv) levels. The determination of vapor pressure values of fentanyl is necessary to understand potential vapor concentrations that may be available for detection. In this paper, vapor pressures of fentanyl free base and fentanyl hydrochloride salt (a common form of the illicit drug) were measured as a function of temperature at or near ambient conditions using the transpiration (gas saturation) method and AFT-MS. Based on our measurements, the vapor pressure of fentanyl at 25 °C is 9.0 × 10-14 atm (90 ppqv), and the vapor pressure of fentanyl hydrochloride at 25 °C is 1.8 x 10-17 atm (0.018 ppqv). We also demonstrate non-contact, real-time vapor detection of fentanyl. Preconcentration of vapors can further extend the detection capabilities. The collection, desorption, and detection of fentanyl vapors at ambient conditions was demonstrated for sampling times of seconds to an hour resulting in increased signal. AFT-MS is a viable detection method of fentanyl and other drugs for screening of packages and cargo.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Interfacing Atmospheric Flow Tube to Ion Mobility Spectrometry: FY 2021 Final Report

An atmospheric flow tube (AFT) provides extended ion-molecule reaction times of 2-3 seconds compared to milliseconds in typical mass spectrometers. This results in several orders of magnitude enhanced sensitivity allowing for vapor detection at the parts-per-quadrillion levels when an AFT is coupled to a mass spectrometer (MS). The goal of this project was to demonstrate the feasibility of integrating an AFT ionization source to a more portable ion mobility spectrometer (IMS). This project was successful in integrating AFT to IMS, as shown in Figure ES.1. The PNNL team demonstrated measurable ion signal from an AFT-IMS with a Faraday plate detector. Reasonable ion signals were detectable at low flow rates approaching 1 m/s. This is close to the flow rates used with the AFT-MS, which has demonstrated parts-per-quadrillion vapor detection. Vapor detection enables non-contact detection of a variety of illicit substances for various applications including cargo screening, mail sorting facilities, and checkpoints. With further improvements to enhance detection, AFT-IMS has the potential to allow ultra-trace vapor detection in a more portable device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗