Search NASA⌕ Search

Engineering topics

Harvey, Scott D

Publications and source records attributed to Harvey, Scott D.

On-matrix Derivatization for Dynamic Headspace Sampling of Nonvolatile Surface Residues

The goal of this study is to extend sampling by the field and laboratory emission cell (FLEC) purge-and-trap technique to applications that target nonvolatile residues. On-matrix derivatization of residues to render analytes stable and more volatile is explored to achieve this goal. Results show that on-matrix derivatizations of nerve agent hydrolysis products (monoalkyl methylphosphonic acids and methylphosphonic acid [MPA]) with diazomethane were successful on glass and painted wallboard (at the 10-µg level). It also was successful on the more difficult concrete (at the 500-µg level) and carpet (at the 20-µg level) substrates that cannot be successfully sampled using swipe techniques. Analysis of additional chemical warfare (CW)-associated residues can be approached by on-matrix derivatization with trifluoroacetic anhydride (TFAA). For example, amines (used as stabilizers or present as decomposition products of the nerve agent VX) or thiodiglycol (hydrolysis product of sulfur mustard) could be sampled as their TFAA derivatives from glass, painted wallboard, and concrete (at the 40-µg level), as well as carpet (at the 80-µg level) surfaces. Although the amine and thiodiglycol are semi-volatile and could be sampled directly, derivatization improves the recovery and chromatographic behavior of these analytes.

On-matrix derivatization, in-situ derivatization, ↗

Preliminary Evaluation of the Field and Laboratory Emission Cell (FLEC) for Sampling Attribution Signatures from Building Materials

This study provides a preliminary evaluation of the Field and Laboratory Emission Cell (FLEC) for its suitability for sampling building materials for toxic compounds and their associated impurities and residues that might remain after a terrorist chemical attack. Chemical warfare (CW) agents and toxic industrial chemicals were represented by a range of test probes that included CW surrogates. The test probes encompassed the acid-base properties, volatilities, and polarities of the expected chemical agents and residual compounds. Results indicated that dissipation of the test probes depended heavily on the underlying material. Near complete dissipation of almost all test probes occurred from galvanized stainless steel within 3.0 hrs, whereas far stronger retention with concomitant slower release was observed for vinyl composition floor tiles. The test probes displayed immediated permanence on Teflon. FLEC sampling was further evaluated by profiling residues remaining after the evaporation of 2-chloroethyl ethyl sulfide, a sulfur mustard simulant. This study lays the groundwork for the eventual goal of applying this sampling approach for collection of forensic attribution signatures that remain after a terrorist chemical attack.

Harvey, Scott D↗

Development of a Simple Field Test for Vehicle Exhaust to Detect Illicit Use of Dyed Diesel Fuel

The use of tax-free dyed fuel on public highways in the United States provides a convenient way of evading taxes. Current enforcement involves visual inspection for the red azo dye added to the fuel to designate its tax-free status. This approach has shortcomings such as the invasive nature of the tests and/or various deceptive tactics applied by tax evaders. A test designed to detect dyed fuel use by analyzing the exhaust would circumvent these shortcomings. This paper describes the development of a simple color spot test designed to detect the use of tax-free (dyed) diesel fuel by analyzing the engine exhaust. Development first investigated the combustion products of C.I. Solvent Red 164 (the azo dye formulation used in the United States to tag tax-free fuel). A variety of aryl amines were identified as characteristic molecular remnants that appear to survive combustion. A number of microanalytical color tests specific for aryl amines were then investigated. One test based on the use of 4-(dimethylamino)benzaldehyde seemed particularly applicable and was used in a proof-of-principle experiment. The 4-(dimethylamino)benzaldehyde color spot test was able to clearly distinguish between engines burning regular and dyed diesel fuel. Further development will refine this color spot test to provide an easy-to-use field test for Internal Revenue Service Field Compliance specialists.

alkyl aryl amines↗

Characterization of Diesel Fuel by Chemical Separation Combined with Capillary Gas Chromatography (GC) Isotope Ratio Mass Spectrometry (IRMS)

The purpose of this study was to perform a preliminary investigation of compound-specific isotope analysis (CSIA) of diesel fuels to evaluate whether the technique could distinguish between the diesel samples from different sources/locations. The ability to differentiate or correlate diesel samples could be valuable for detecting fuel tax evasion schemes. Two fractionation techniques were used to isolate the n-alkanes from the fuel. Both δ13C and δD values for the n-alkanes were then determined by CSIA in each sample. Plots of δD versus δ13C with sample n-alkane points connected in order of increasing carbon number gave well separated clusters with characteristic shapes for each sample. Principal components analysis (PCA) with δ13C, δD, or combined δ13C and δD data on the yielded scores plots that could clearly differentiate the samples, thereby demonstrating the potential of this approach for fingerprinting fuel samples using the δ13C and δD values.

compound specific isotope ratio mass spectrometry↗

Evaluation of Copper-1,3,5-benzenetricarboxylate Metal-organic Framework (Cu-MOF) as a Selective Sorbent for Lewis-base Analytes

The metal-organic framework Cu-BTC was evaluated for its ability to selectively interact with Lewis-base analytes, including explosives, by examining retention on GC columns packed with Chromosorb W HP that contained 3.0% SE-30 along with various loadings of Cu-BTC. SEM images of the support material showed the characteristic Cu-BTC crystals embedded in the SE-30 coating on the diatomaceous support. Results indicated that the Cu-BTC-containing stationary phase had limited thermal stability (220°C) and strong general retention for analytes. Kováts index calculations showed selective retention (amounting to about 300 Kováts units) relative to n-alkanes for many small Lewis-base analytes on a column that contained 0.75% Cu-BTC compared to an SE-30 control. Short columns that contained lower loadings of Cu-BTC (0.10%) were necessary to elute explosives and related analytes; however, selectivity was not observed for aromatic compounds (including nitroaromatics) or nitroalkanes. Observed retention characteristics are discussed.

36 MATERIALS SCIENCE↗

Method and apparatus for selective capture of gas phase analytes using metal .beta.-diketonate polymers

A process and sensor device are disclosed that employ metal .beta.-diketonate polymers to selectively capture gas-phase explosives and weaponized chemical agents in a sampling area or volume. The metal .beta.-diketonate polymers can be applied to surfaces in various analytical formats for detection of: improvised explosive devices, unexploded ordinance, munitions hidden in cargo holds, explosives, and chemical weapons in public areas.

47 OTHER INSTRUMENTATION↗

Method and apparatus for selective capture of gas phase analytes using metal .beta.-diketonate polymers

A process and sensor device are disclosed that employ metal .beta.-diketonate polymers to selectively capture gas-phase explosives and weaponized chemical agents in a sampling area or volume. The metal .beta.-diketonate polymers can be applied to surfaces in various analytical formats for detection of: improvised explosive devices, unexploded ordinance, munitions hidden in cargo holds, explosives, and chemical weapons in public areas.

47 OTHER INSTRUMENTATION↗

Surrogate Nuclear Explosion Debris for Measurement Validation and Research

ABSTRACT There is intense interest in characterizing nuclear explosion debris following the terrorist use of a nuclear weapon or improvised nuclear device. The quality of the laboratory analyses of such samples is critical if action is to be taken based on those analyses. Thus, validating methods against well characterized nuclear debris is of interest, however, actual nuclear explosion debris is difficult to obtain. PNNL has embarked on a program to develop laboratory methods to synthesize materials which mimic nuclear explosion debris with respect to selected characteristics. Which characteristics are mimicked depends on the application. For tests of laboratory radioanalytical capabilities, materials with relatively few characteristics in common with actual debris are useful. For other applications, material properties may need to match real debris to a greater extent, e.g., for fate and transport studies the chemical behavior should match real debris in detail. We will describe methods by which these materials can be produced and highlight some of the issues associated with such operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Selective Retention of Explosives and Related Compounds on Gas-Chromatographic Capillary Columns Coated with Lanthanide(III) ß-diketonate Polymers

The purpose of this research was to investigate coating capillary columns with lanthanide(III) beta-diketonate polymers to provide gas-chromatographic columns with selectivity toward explosives and related compounds. Capillary columns were statically coated with a combination of a lanthanide(III) beta-diketonate polymer, which utilized p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene (dihed) as a ligand, and SE-30. A novel coating technique was developed that used a methanol-containing azeotrope to provide solubility for both polymers while maintaining a low boiling point compatible with static coating. As based on temperature-programmed retention indices, the custom experimental columns displayed selective retention of nitroaromatic, nitroalkane, and nitrate ester test probes relative to an appropriate SE-30 control column. Selective retention was more pronounced for strong Lewis base analytes (i.e., cyclohexanone). Relative analyte retention on the La(dihed), Tb(dihed) and Eu(dihed) columns are discussed relative to Lewis acidity and solubility of the polymer in the azeotrope coating solution.

36 MATERIALS SCIENCE↗

Selective Sampling with Direct Ion Mobility Spectrometric Detection for Explosives Analysis

This study investigates the potential and limitations of a streamlined, field-deployable analytical approach that involves selective capture of explosive materials with direct analysis by ion mobility spectrometry (IMS). Selective capture of explosives was performed on deactivated quartz fiber filters impregnated with metal β-diketonate polymers. These Lewis acidic polymers selectively interact with Lewis base analytes such as explosives. The filter coupons could be directly inserted into an IMS instrument for analysis. The uptake kinetics of 2,4,6-trinitrotoluene (TNT) from a saturated atmosphere were characterized, and based on these studies, passive equilibrium sampling was applied to estimate the TNT concentration within an ammunition magazine that contained bulk TNT. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) uptake from a saturated environment also was examined over a one-month period. Each incremental sampling period showed increasing quantities of RDX culminating with collection of approximately 5 ng of RDX on the coupon at the end of one month. This is the first time that gas-phase uptake of RDX has been demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Structure and Purity of a Reference Dye Standard used for Quantification of C.I. Solvent Red 164 in Fuels

This research describes a comprehensive analytical approach to provide structure verification and purity determination for Morton Red 26. Studies presented in this paper, based on application of numerous traditional and advanced analytical techniques, provide definitive proof that Morton Red 26 and Solvent Red 26 are not chemically equivalent and, further, that Morton Red 26 and NIST #2037 have identical chemical structures, a result that stands in contrast to common perception. Additional analytical studies, again based on the application of numerous analytical methodologies, determined that Morton Red 26 was approximately 72 percent pure, a finding that stands in contrast to the 99 percent purity value certified by the supplier (Morton International). Possible explanations and implications are briefly discussed. Several of the Morton Red 26 impurities were tentatively identified, and a host of additional impurities were partially characterized by NMR, TLC, GC/MS, and HPLC/MS studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective solid-phase microextraction of explosives using fibers coated with the La (III) complex of p-di (4,4,5,5,6,6,6-hepafluoro-1,3-hexanediony) benzene

This research demonstrates enhanced capture of explosives on polydimethylsiloxane (PDMS) solid-phase microextraction (SPME) fibers coated with a metal beta-diketonate polymer, [La(III) complex of p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene, La(dihed)], compared to PDMS control fibers. SPME sampling was performed in an explosives bunker where the concentration of 2,4,6-trinitrotoluene (TNT) was estimated at less than 3 parts-per-trillion (v/v). Analysis by gas chromatography/mass spectrometry showed an approximate ten-fold enhancement in the quantity of 2,4-dinitrotoluene captured on La(dihed) over the control fiber. La(dihed) sampling also resulted in a strong signal for TNT, whereas this explosive was well below the detection limit (1 pg on fiber) on the control fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗