Abstract

This study investigates the potential and limitations of a streamlined, field-deployable analytical approach that involves selective capture of explosive materials with direct analysis by ion mobility spectrometry (IMS). Selective capture of explosives was performed on deactivated quartz fiber filters impregnated with metal β-diketonate polymers. These Lewis acidic polymers selectively interact with Lewis base analytes such as explosives. The filter coupons could be directly inserted into an IMS instrument for analysis. The uptake kinetics of 2,4,6-trinitrotoluene (TNT) from a saturated atmosphere were characterized, and based on these studies, passive equilibrium sampling was applied to estimate the TNT concentration within an ammunition magazine that contained bulk TNT. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) uptake from a saturated environment also was examined over a one-month period. Each incremental sampling period showed increasing quantities of RDX culminating with collection of approximately 5 ng of RDX on the coupon at the end of one month. This is the first time that gas-phase uptake of RDX has been demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Harvey, Scott D, Ewing, Robert G, Waltman, Melanie J. 2009-06-29. Selective Sampling with Direct Ion Mobility Spectrometric Detection for Explosives Analysis. https://doi.org/10.1007/s12127-009-0031-z. https://searchnasa.com/record/osti%3A989038/selective-sampling-with-direct-ion-mobility-spectrometric-detection-for-explosives-analysis

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Morgana Overview – NCERC Support for Dynamic Subcritical Experiments

The LANL Subcritical Experiments Program (SCE) recently executed the Morgana Subcritical Experiment at the NNSS. This was the first subcritical experiment executed by LANL for several years (since 2021). It was also notably the first that required SCE personnel to have FMH qualifications for a portion of the work conducted under nuclear criticality safety limits.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

AWSD Reactive Burn Model for the HMX‐Based High Explosive LX‐04

An Arrhenius–Wescott–Stewart–Davis (AWSD) reactive burn model is applied to describe shock initiation and detonation properties of the HMX-based high explosive LX-04. The parameters in the model are calibrated to data from multiple sources. The thermodynamic equations of state used in the model are calibrated to a combination of thermochemical calculations for HMX and LX-04 as well as experimentally-measured cylinder expansion results for LX-04. The kinetic parameters are calibrated to velocity data from gas gun experiments performed using EDC-32—a high explosive with the same chemical composition as LX-04 but different structural properties, and scaled rate stick data for PBX 9012. The AWSD model is shown to accurately describe the shock initiation and propagation of LX-04. Very good agreement is observed between the available experimental data and the AWSD model output. The presented results constitute an accurate LX-04 reactive burn model for use in engineering-scale models and simulations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.