Search NASA⌕ Search

Engineering topics

Heeter, R. F. (ORCID:0000000310971823)

Publications and source records attributed to Heeter, R. F. (ORCID:0000000310971823).

Ionization disequilibrium in K- and L-shell ions

Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7–4.6 keV energy range

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900–2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films’ higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

Dutra, E. C. (ORCID:0000000167649195)↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗