Search NASA⌕ Search

Engineering topics

Hurley, E. J.

Publications and source records attributed to Hurley, E. J..

Propane spectral resolution enhancement by the maximum entropy method

The Burg algorithm for maximum entropy power spectral density estimation is applied to a time series of data obtained from a Michelson interferometer and compared with a standard FFT estimate for resolution capability. The propane transmittance spectrum was estimated by use of the FFT with a 2 to the 18th data sample interferogram, giving a maximum unapodized resolution of 0.06/cm. This estimate was then interpolated by zero filling an additional 2 to the 18th points, and the final resolution was taken to be 0.06/cm. Comparison of the maximum entropy method (MEM) estimate with the FFT was made over a 45/cm region of the spectrum for several increasing record lengths of interferogram data beginning at 2 to the 10th. It is found that over this region the MEM estimate with 2 to the 16th data samples is in close agreement with the FFT estimate using 2 to the 18th samples.

Bonavito, N. L.↗

The status of the Nimbus-7 earth-radiation-budget data set

Over six years of data from the earth-radiation-budget (ERB) experiment on board the Nimbus-7 spacecraft have been received to date. Five years of data have been archived and are readily available to the scientific community, while the sixth year's data will be archived by the fall of 1985. There are three complementary, but independent, data sets: earth-radiation-budget data, solar-irradiance data, and shortwave- and longwave-radiance data suitable for bidirectional-reflectance studies. The solar and the wide-field-of-view earth-flux channels are still recording high-quality data, but the narrow-field-of-view scanner failed after 20 months. The condition of the three data sets is described. In addition, plans for data-set improvement are discussed and a simple algorithm to improve the wide-field-of-view data is presented.

Kyle, H. L.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗