Search NASASearch

Engineering topics

Jones, M.

Publications and source records attributed to Jones, M..

At least 19 records

Quasielastic $\overrightarrow{^{3}He}$ $(\overrightarrow{e},e′)$ asymmetry in the threshold region with a longitudinally polarized target

We report on the measurements of the double-spin asymmetry from electron- 3 He scattering in the threshold region of two- and three-body breakup of 3 He for 4-momentum transfer values of 0.1 and 0.2 (GeV/c) 2 . The measurement was done at Jefferson Lab using a polarized 3 He target with its spin aligned parallel to the beam direction. This asymmetry is sensitive to a combination of spin-dependent response functions not previously measured and may highlight differences in two body forces, meson-exchange currents and final-state interactions. The results of this measurement serve as a test of our understanding of few-body systems. When compared with calculations from plane wave impulse approximation and Faddeev calculations, we found that the latter, which use modern nuclear potentials and prescriptions for meson-exchange currents, demonstrate an overall good agreement with data.

Few-body nuclei

Investigation of oscillations above the acoustic cut-off frequency for a sample of Kepler stars. II. Identifying temporal frequency shifts

ABSTRACT Stellar oscillations with frequencies greater than the acoustic cut-off frequency are not trapped within the star’s interior. Geometric interference between these high-frequency waves produces a peak-like structure in the power spectrum of the star, known as the pseudo-modes. In this study, we aim to analyse 51 stars previously identified (from a sample of 91 Kepler stars) to contain statistically significant evidence for pseudo-modes, to determine if the pseudo-mode frequencies vary in time. We obtained these frequency variations and the uncertainty by the resampled periodogram approach, where periodogram realisations were created from successive, overlapping 90-d time segments, and a cross-correlation function was generated between them. The computed shifts were compared against temporal p-mode frequency shifts and a stellar magnetic activity proxy, $S_{\mathrm{ph}}$. We found that for 16 per cent of the stars pseudo-mode frequency shifts were significantly anticorrelated with p-mode shifts, as is the case for the Sun. However, we also found pseudo-mode and p-mode shifts to be significantly correlated in-phase in 8 per cent of our sample. The remainder showed no significant correlation. We also searched for trends between the maximum variation of pseudo-mode frequency shifts and stellar parameters. Whilst we found no correlation between the maximum variation and stellar photospheric and chromospheric proxies, we found frequency variations to have a greater amplitude for cooler and slower rotating stars, which is in opposition to p-mode frequency shift variation. Temporal changes to pseudo-mode frequencies may be attributable to variations in stellar magnetic activity, and therefore can contribute to our understanding of stellar activity cycles.

Millson, L. J. (ORCID:0009000342542676)

LiteBIRD: An All-Sky Cosmic Microwave Background Probe of Inflation

The LiteBIRD mission will map polarized fluctuations in the cosmic microwave background (CMB) to search for the signature of gravitational waves from inflation, potentially opening a window on the Universe a fraction of a second after the Big Bang. CMB measurements from space give access to the largest angular scales and the full frequency range to constrain Galactic foregrounds, and LiteBIRD has been designed to take best advantage of the unique window of space. LiteBIRD will have a powerful ability to separate Galactic foreground emission from the CMB due to its 15 frequency bands spaced between 40 and 402 GHz and sensitive 100-mK bolometers. LiteBIRD will provide stringent control of systematic errors due to the benign thermal environment at the second Lagrange point, L2, 20-K rapidly rotating half-wave plates on each telescope, and the ability to crosscheck its results by measuring both the reionization and recombination peaks in the B-mode power spectrum. LiteBIRD would be the next step in the series of CMB space missions, COBE, WMAP, and Planck, each of which has given landmark scientific discoveries.

Lee, Adrian T.

Acoustic Treatment Design Scaling Methods

The ability to design, build and test miniaturized acoustic treatment panels on scale model fan rigs representative of full scale engines provides not only cost-savings, but also an opportunity to optimize the treatment by allowing multiple tests. To use scale model treatment as a design tool, the impedance of the sub-scale liner must be known with confidence. This study was aimed at developing impedance measurement methods for high frequencies. A normal incidence impedance tube method that extends the upper frequency range to 25,000 Hz. without grazing flow effects was evaluated. The free field method was investigated as a potential high frequency technique. The potential of the two-microphone in-situ impedance measurement method was evaluated in the presence of grazing flow. Difficulties in achieving the high frequency goals were encountered in all methods. Results of developing a time-domain finite difference resonator impedance model indicated that a re-interpretation of the empirical fluid mechanical models used in the frequency domain model for nonlinear resistance and mass reactance may be required. A scale model treatment design that could be tested on the Universal Propulsion Simulator vehicle was proposed.

Clark, L.

Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

NASA Discipline Cardiopulmonary

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

NASA Discipline Cardiopulmonary

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies

New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.

NASA Discipline Cardiopulmonary

SCOS 2: ESA's new generation of mission control system

New mission-control infrastructure is currently being developed by ESOC, which will constitute the second generation of the Spacecraft Control Operations system (SCOS 2). The financial, functional and strategic requirements lying behind the new development are explained. The SCOS 2 approach is described. The technological implications of these approaches is described: in particular it is explained how this leads to the use of object oriented techniques to provide the required 'building block' approach. The paper summarizes the way in which the financial, functional and strategic requirements have been met through this combination of solutions. Finally, the paper outlines the development process to date, noting how risk reduction was achieved in the approach to new technologies and summarizes the current status future plans.

Jones, M.

The anemia of primary autonomic failure and its reversal with recombinant erythropoietin

OBJECTIVE: To determine if chronic sympathetic deprivation is associated with anemia and a low erythropoietin response. DESIGN: Survey of the prevalence and characteristics of anemia in patients with severe primary autonomic failure. SETTING: A referral service for autonomic failure in a tertiary teaching hospital. PATIENTS: 84 patients with primary autonomic failure who had symptomatic orthostatic hypotension. INTERVENTION: Open-label trial with human recombinant erythropoietin. RESULTS: Anemia was present in 32 of 84 patients (38%; 95% Cl, 27% to 50%). Plasma norepinephrine levels, measured in patients standing upright, were lower in the patient group with lower hemoglobin levels. Mean values in 22 patients with a hemoglobin level of less than 120 g/L were as follows: hemoglobin, 108 g/L (range, 87 to 118 g/L); hematocrit, 0.33; corrected reticulocyte counts, 0.008; mean corpuscular volume, 89 fL (89 microns 3); serum iron, 16.5 mumol/L (92 micrograms/dL); total iron binding capacity, 43.3 mumol/L (242 micrograms/dL); ferritin, 184 micrograms/L; serum vitamin B12, 410 pmol/L (556 pg/mL); and serum folate, 22.7 nmol/L (10 ng/mL). No relation was found between serum erythropoietin and blood hemoglobin levels. In seven of nine patients with autonomic failure who had hemoglobin levels less than 120 g/L, serum erythropoietin levels decreased below the 95% confidence interval corresponding to patients with iron deficiency anemia. Therapy with recombinant erythropoietin improved mean hemoglobin levels (from 108 to 133 g/L) in all patients treated (n = 5) at relatively low doses (25 to 50 units/kg body weight, subcutaneously, three times a week). CONCLUSIONS: Our data support the hypothesis that the sympathetic nervous system stimulates erythropoiesis in humans because anemia is a frequent occurrence in patients with severe autonomic failure and is associated with a blunted erythropoietin response.

Clinical Trial

A review of mission planning systems

A general definition of Mission Planning is given. The definition covers the full scope of an end-to-end mission planning system. Noting the mission-specific nature of most mission planning systems, a classification of autonomous spacecraft missions is made into Observatory, Survey, multi-instrument science, and Telecommunications missions. The mission planning approach for one mission in each category is examined critically. The following missions were chosen: ISO (Infrared Space Observatory); ERS-1 (European Remote Sensing Satellite); and Eureca (European Retrievable Carrier). The paper gives a summary of lessons learned from these missions suggesting improvements in areas such as requirements analysis, testing, user interfacing, rules, and constraints handling. The paper will also examine commonalities in functions, which could constitute a basis for identification of generic mission planning support tools.

Jones, M.

Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

Kellogg, E.

Electrical, magnetic, and optical properties of the tetrathiafulvalene /TTF/ pseudohalides, /TTF/12/SCN/7 and /TTF/12/SeCN/7

The electrical, magnetic, and optical properties of charge-transfer salts containing tetrathiafulvalene (TTF) and the pseudohalides, thiocyanate (SCN) and selenocyanate (SeCN), have been investigated. These salts are quasi-one-dimensional compounds containing cation radicals only, in contrast to a cation-radical-anion-radical system, such as tetrathiafulvalene tetracyanoquinodimethane (TTF) (TCNQ). Measurements of electrical conductivity, thermoelectric power, and optical reflectivity of single crystals of the nonstoichiometric salts (TTF)12(SCN)7 and (TTF)12(SeCN)7 show metal-like characteristics above 200 K (high-temperature region). The conductivities at room temperature are approximately 750 mho/cm comparable to those found in (TTF) (TCNQ), and increase with decreasing temperature down to approximately 200 K. The thermoelectric power at room temperature is small and positive (approximately 9 microvolts/deg K), and decreases linearly with decreasing temperature in this region (as expected for metal-like hole conduction along the TTF chains). The ESR intensity, however, decreases with decreasing temperature above 200 K. At 170 K a metal-nonmetal transition occurs, and the transport and magnetic properties below this temperature are characteristic of a semiconducting state.

Somoano, R. B.