Search NASA⌕ Search

Engineering topics

Jones, M.

Publications and source records attributed to Jones, M..

At least 19 records

Quasielastic $\overrightarrow{^{3}He}$ $(\overrightarrow{e},e′)$ asymmetry in the threshold region with a longitudinally polarized target

We report on the measurements of the double-spin asymmetry from electron- 3 He scattering in the threshold region of two- and three-body breakup of 3 He for 4-momentum transfer values of 0.1 and 0.2 (GeV/c) 2 . The measurement was done at Jefferson Lab using a polarized 3 He target with its spin aligned parallel to the beam direction. This asymmetry is sensitive to a combination of spin-dependent response functions not previously measured and may highlight differences in two body forces, meson-exchange currents and final-state interactions. The results of this measurement serve as a test of our understanding of few-body systems. When compared with calculations from plane wave impulse approximation and Faddeev calculations, we found that the latter, which use modern nuclear potentials and prescriptions for meson-exchange currents, demonstrate an overall good agreement with data.

Few-body nuclei↗

Investigation of oscillations above the acoustic cut-off frequency for a sample of Kepler stars. II. Identifying temporal frequency shifts

ABSTRACT Stellar oscillations with frequencies greater than the acoustic cut-off frequency are not trapped within the star’s interior. Geometric interference between these high-frequency waves produces a peak-like structure in the power spectrum of the star, known as the pseudo-modes. In this study, we aim to analyse 51 stars previously identified (from a sample of 91 Kepler stars) to contain statistically significant evidence for pseudo-modes, to determine if the pseudo-mode frequencies vary in time. We obtained these frequency variations and the uncertainty by the resampled periodogram approach, where periodogram realisations were created from successive, overlapping 90-d time segments, and a cross-correlation function was generated between them. The computed shifts were compared against temporal p-mode frequency shifts and a stellar magnetic activity proxy, $S_{\mathrm{ph}}$. We found that for 16 per cent of the stars pseudo-mode frequency shifts were significantly anticorrelated with p-mode shifts, as is the case for the Sun. However, we also found pseudo-mode and p-mode shifts to be significantly correlated in-phase in 8 per cent of our sample. The remainder showed no significant correlation. We also searched for trends between the maximum variation of pseudo-mode frequency shifts and stellar parameters. Whilst we found no correlation between the maximum variation and stellar photospheric and chromospheric proxies, we found frequency variations to have a greater amplitude for cooler and slower rotating stars, which is in opposition to p-mode frequency shift variation. Temporal changes to pseudo-mode frequencies may be attributable to variations in stellar magnetic activity, and therefore can contribute to our understanding of stellar activity cycles.

Millson, L. J. (ORCID:0009000342542676)↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonvirialized axion search sensitive to Doppler effects in the Milky Way halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki- Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. Here, we report the results of a non-virialized axion search over the mass range 2.81–3.31 µeV, corresponding to the frequency range 680–800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector’s motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of $\mathscr{O}$(10 -7 )c with 95% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields

This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment (ADMX), because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

43 PARTICLE ACCELERATORS↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Measurement of R = σ L / σ T and the separated longitudinal and transverse structure functions in the nucleon-resonance region

Here we report on a detailed study of longitudinal strength in the nucleon resonance region, presenting new results from inclusive electron-proton cross sections measured at Jefferson Lab Hall C in the four-momentum transfer range 0.2 < Q 2 < 5.5 GeV 2 . The data have been used to accurately perform over 170 Rosenbluth-type longitudinal/transverse separations. The precision R = $\sigma_{L} /\sigma _{T}$ data are presented here, along with the first separate values of the inelastic structure functions F 1 and F L in this regime. The resonance longitudinal component is found to be significant. With the new data, quark-hadron duality is observed above Q 2 = 1 GeV 2 in the separated structure functions independently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Form Factors and Two-Photon Exchange in High-Energy Elastic Electron-Proton Scattering

We report new precision measurements of the elastic electron-proton scattering cross section for momentum transfer squared (Q$^2$) up to 15.75 (GeV/c)$^2$. These data allow for improved extraction of the proton magnetic form factor at high Q$^2$ and nearly double the Q$^2$ range of direct longitudinal/transverse separated cross sections. A comparison of our results to polarization measurements establishes the presence of hard two-photon exchange in the $e$-$p$ elastic scattering cross section at > 95 % confidence level for Q$^2$ up to 8 (GeV/c)$^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy of A=9 hyperlithium with the $(e,e^{\prime}K^{+})$ reaction

Missing mass spectroscopy with the $(e,e^{\prime}K^{+})$ reaction was performed at JLab Hall C for the neutron rich $\Lambda$ hypernucleus $^{9}_{\Lambda}{\rm Li}$. The ground state energy was obtained to be $B_{\Lambda}^{\rm g.s.}=8.84\pm0.17^{\rm stat.}\pm0.15^{\rm sys.}~{\rm MeV}$ by using shell model calculations of a cross section ratio and an energy separation of the spin doublet states ($3/2^{+}_1$ and $5/2^{+}_1$). In addition, peaks that are considered to be states of [$^{8}{\rm Li}(3^{+})\otimes s_{\Lambda}=3/2^{+}_{2}, 1/2^{+}$] and [$^{8}{\rm Li}(1^{+})\otimes s_{\Lambda}=5/2^{+}_{2}, 7/2^{+}$] were observed at $E_{\Lambda}(\#2)=1.74\pm0.27^{\rm stat.}\pm0.11^{\rm sys.}~{\rm MeV}$ and $E_{\Lambda}(\#3)=3.30\pm0.24^{\rm stat.}\pm0.11^{\rm sys.}~{\rm MeV}$, respectively. The $E_{\Lambda}(\#3)$ is larger than shell model predictions by a few hundred keV, and the difference would indicate that a ${\rm ^{5}He}+t$ structure is more developed for the $3^{+}$ state than those for the $2^{+}$ and $1^{+}$ states in a core nucleus $^{8}{\rm Li}$ as a cluster model calculation suggests.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗