Search NASA⌕ Search

Engineering topics

Jones, M.

Publications and source records attributed to Jones, M..

At least 37 records · Page 2

Proton form factor ratio μ p G E p / G M p from double spin asymmetry

We report the ratio of the electric and magnetic form factor of the proton, $\mu_p G_E^p/G_M^p$, has been measured for elastic electron-proton scattering with polarized beam and target up to four-momentum transfer squared, $Q^2=5.66$ (GeV/c)$^2$ using the double spin asymmetry for target spin orientation aligned nearly perpendicular to the beam momentum direction. This measurement of $\mu_p G_E^p/G_M^p$ agrees with the $Q^2$ dependence of previous recoil polarization data and reconfirms the discrepancy at high $Q^2$ between the Rosenbluth and the polarization-transfer method with a different measurement technique and systematic uncertainties uncorrelated to those of the recoil-polarization measurements. The form factor ratio at $Q^2$=2.06 (GeV/c)$^2$ has been measured as $\mu_p G_E^p/G_M^p = 0.720 \pm 0.176_{stat} \pm 0.039_{sys}$, which is in agreement with an earlier measurement with the polarized target technique at similar kinematics. The form factor ratio at $Q^2$=5.66 (GeV/c)$^2$ has been determined as $\mu_p G_E^p/G_M^p=0.244\pm0.353_{stat}\pm0.013_{sys}$, which represents the highest $Q^2$ reach with the double spin asymmetry with polarized target to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extended Search for the Invisible Axion with the Axion Dark Matter Experiment

This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range 2.81–3.31 µeV . This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first-stage signal amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LiteBIRD: An All-Sky Cosmic Microwave Background Probe of Inflation

The LiteBIRD mission will map polarized fluctuations in the cosmic microwave background (CMB) to search for the signature of gravitational waves from inflation, potentially opening a window on the Universe a fraction of a second after the Big Bang. CMB measurements from space give access to the largest angular scales and the full frequency range to constrain Galactic foregrounds, and LiteBIRD has been designed to take best advantage of the unique window of space. LiteBIRD will have a powerful ability to separate Galactic foreground emission from the CMB due to its 15 frequency bands spaced between 40 and 402 GHz and sensitive 100-mK bolometers. LiteBIRD will provide stringent control of systematic errors due to the benign thermal environment at the second Lagrange point, L2, 20-K rapidly rotating half-wave plates on each telescope, and the ability to crosscheck its results by measuring both the reionization and recombination peaks in the B-mode power spectrum. LiteBIRD would be the next step in the series of CMB space missions, COBE, WMAP, and Planck, each of which has given landmark scientific discoveries.

Lee, Adrian T.↗

Revealing Color Forces with Transverse Polarized Electron Scattering

The Spin Asymmetries of the Nucleon Experiment measured two double spin asymmetries using a polarized proton target and polarized electron beam at two beam energies, 4.7 and 5.9 GeV. A large acceptance open-configuration detector package identified scattered electrons at 40° and covered a wide range in Bjorken $\mathcal{x}$ (0.3< $\mathcal{x}$ <0.8). Proportional to an average color Lorentz force, the twist-3 matrix element, $\tilde{d}$$p\atop{2}$, was extracted from the measured asymmetries at Q 2 values ranging from 2.0 to 6.0 GeV 2 . The data display the opposite sign compared to most quark models, including the lattice QCD result, and an unexpected scale dependence. Moreover, when combined with the neutron data in the same Q 2 range the results suggest a flavor independent average color Lorentz force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Piezoelectrically Tuned, Multimode Cavity Search for Axion Dark Matter

The eV axion is a well-motivated extension to the standard model. The Axion Dark Matter 27 eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant con28 version of dark-matter axions to microwave photons in a strong magnetic eld. In this paper we 29 report results from an ADMX pathnder experiment, the ADMX \Sidecar", which is designed to 30 pave the way for future, higher mass, searches. The Sidecar experiment excludes masses in three 31 widely spaced frequency ranges (4202-4249 MHz, 5086-5799 MHz and 7173-7203 MHz), correspond32 ing to masses favored by some cosmic string simulations. In addition, Sidecar demonstrates the 33 successful use of piezoelectric actuators for both cavity tuning and antenna coupling. Finally, this publication is the rst to report data taken on both the TM010 and TM020 modes.

Boutan, Christian R.↗

Direct measurements of the lifetime of medium-heavy hypernuclei

The lifetime of a Λ particle embedded in a nucleus (hypernucleus) decreases from that of free Λ decay mainly due to the opening of the Λ N → NN weak decay channel. Furthermore, it is generally believed that the lifetime of a hypernucleus attains a constant value (saturation) for medium to heavy hypernuclear masses, yet this hypothesis has been difficult to verify. This paper presents a direct measurement of the lifetime of medium-heavy hypernuclei that were hyper-fragments produced by fission or break-up from heavy hypernuclei initially produced with a 2.34 GeV photon-beam incident on thin Fe, Cu, Ag, and Bi target foils. For each event, fragments were detected in coincident pairs by a low-pressure multi-wire proportional chamber system. The lifetime was extracted from decay time spectrum formed by the difference of the time zeros between the pairs. The measured lifetime from each target is actually a statistical average over a range of mass with mean about 1/2 of the target mass and appears to be a constant of about 200 ps. Although this result cannot exclude unexpected shorter or longer lifetimes for some specific hypernuclei or hypernuclear states, it shows that a systematic decrease in lifetime as hypernuclear mass increases is not a general feature for hypernuclei with mean mass up to A ≈ 130. On the other hand, the success of this experiment and its technique shows that the time delayed fissions observed and used by all the lifetime measurements done so far on heavy hypernuclei could likely have originated from hyper-fragments lighter than the assumed masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extraction of the neutron electric form factor from measurements of inclusive double spin asymmetries

Background: Measurements of the neutron charge form factor, G$n\atop{E}$, are challenging because the neutron has no net charge. Additionally, measurements of the neutron form factors must use nuclear targets which require accurately accounting for nuclear effects. Extracting G$n\atop{E}$ with different targets and techniques provides an important test of our handling of these effects. Purpose: The goal of the measurement was to use an inclusive asymmetry measurement technique to extract the neutron charge form factor at a four-momentum transfer of 1 (GeV/c) 2 . This technique has very different systematic uncertainties than traditional exclusive measurements and thus serves as an independent check of whether nuclear effects have been taken into account correctly. Method: The inclusive quasielastic reaction 3 $→\atop{He}$ ($→\atop{e}$, e') was measured at Jefferson Laboratory. The neutron electric form factor, G$n\atop{E}$, was extracted at Q 2 = 0.98 ( GeV/c) 2 from ratios of electron-polarization asymmetries measured for two orthogonal target spin orientations. This Q 2 is high enough that the sensitivity to G$n\atop{E}$ is not overwhelmed by the neutron magnetic contribution, and yet low enough that explicit neutron detection is not required to suppress pion production. Results: The neutron electric form factor, G$n\atop{E}$, was determined to be 0.0414 ± 0.0077 ( stat ) ± 0.0022 ( syst ), providing the first high-precision inclusive extraction of the neutron's charge form factor. In conclusion: The use of the inclusive quasielastic 3 $→\atop{He}$ ($→\atop{e}$, e') with a four-momentum transfer near 1 (GeV/c) 2 has been used to provide a unique measurement of G$n\atop{E}$. This new result provides a systematically independent validation of the exclusive extraction technique results and implies that the nuclear corrections are understood. This is contrary to the proton form factor where asymmetry and differential cross section measurements have been shown to have large systematic differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and performance of the spin asymmetries of the nucleon experiment

The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer 2.5 < Q 2 < 6.5 GeV 2 and Bjorken scaling 0.3 < x < 0.8 from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target which could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables A 1 , A 2 , g 1 , g 2 and moment d 2 of the proton. This article summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.

43 PARTICLE ACCELERATORS↗

Q weak : First direct measurement of the proton’s weak charge

The Q weak experiment, which took data at Jefferson Lab in the period 2010 - 2012, will precisely determine the weak charge of the proton by measuring the parity-violating asymmetry in elastic e-p scattering at 1.1 GeV using a longitudinally polarized electron beam and a liquid hydrogen target at a low momentum transfer of Q 2 = 0.025 (GeV/c) 2 . The weak charge of the proton is predicted by the Standard Model and any significant deviation would indicate physics beyond the Standard Model. The technical challenges and experimental apparatus for measuring the weak charge of the proton will be discussed, as well as the method of extracting the weak charge of the proton. Finally, the results from a small subset of the data, that has been published, will also be presented. Furthermore an update will be given of the current status of the data analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The tracking analysis in the Q-weak experiment

Here, the Q-weak experiment at Jefferson Laboratory measured the parity violating asymmetry (A$_{PV}$ ) in elastic electron-proton scattering at small momentum transfer squared (Q$^{2}$=0.025 (G e V/c)$^{2}$), with the aim of extracting the proton’s weak charge ( ${Q^p_W}$ ) to an accuracy of 5 %. As one of the major uncertainty contribution sources to ${Q^p_W}$ , Q$^{2}$ needs to be determined to ~1 % so as to reach the proposed experimental precision. For this purpose, two sets of high resolution tracking chambers were employed in the experiment, to measure tracks before and after the magnetic spectrometer. Data collected by the tracking system were then reconstructed with dedicated software into individual electron trajectories for experimental kinematics determination. The Q-weak kinematics and the analysis scheme for tracking data are briefly described here. The sources that contribute to the uncertainty of Q$^{2}$ are discussed, and the current analysis status is reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DAQ for commissioning and calibration of a multichannel analyzer of scintillation counters

We report the status of the Data Acquisition (DAQ) system for the Coordinate Detector (CDET) module of the Super Bigbite Spectrometer facility at Hall A of Thomas Jefferson Accelerator Facility. Presently, the DAQ is fully assembled and tested with one CDET module. The commissioning of CDET module, that is the goal of the tests presented here, consists essentially in the measures of the amplitude and time-over-threshold of signals from cosmic rays. Hardware checks, the developing of DAQ control and off-line analysis software are ongoing; the module currently seems to work roughly accordingly to expectations. Data presented in this note are still preliminary.

Tortorici, F.↗

Spectroscopy of the neutron-rich hypernucleus He Λ 7 from electron scattering

Here, the missing mass spectroscopy of the $^{7}_{\Lambda}$He hypernucleus was performed, using the $^{7}$Li$(e,e^{\prime}K^{+})^{7}_{\Lambda}$He reaction at the Thomas Jefferson National Accelerator Facility Hall C. The $\Lambda$ binding energy of the ground state (1/2$^{+}$) was determined with a smaller error than that of the previous measurement, being $B_{\Lambda}$ = 5.55 $\pm$ 0.10(stat.) $\pm$ 0.11(sys.) MeV. The experiment also provided new insight into charge symmetry breaking in p-shell hypernuclear systems. Finally, a peak at $B_{\Lambda}$ = 3.65 $\pm$ 0.20(stat.) $\pm$ 0.11(sys.) MeV was observed and assigned as a mixture of 3/2$^{+}$ and 5/2$^{+}$ states, confirming the "gluelike" behavior of $\Lambda$, which makes an unstable state in $^{6}$He stable against neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Acoustic Treatment Design Scaling Methods

The ability to design, build and test miniaturized acoustic treatment panels on scale model fan rigs representative of full scale engines provides not only cost-savings, but also an opportunity to optimize the treatment by allowing multiple tests. To use scale model treatment as a design tool, the impedance of the sub-scale liner must be known with confidence. This study was aimed at developing impedance measurement methods for high frequencies. A normal incidence impedance tube method that extends the upper frequency range to 25,000 Hz. without grazing flow effects was evaluated. The free field method was investigated as a potential high frequency technique. The potential of the two-microphone in-situ impedance measurement method was evaluated in the presence of grazing flow. Difficulties in achieving the high frequency goals were encountered in all methods. Results of developing a time-domain finite difference resonator impedance model indicated that a re-interpretation of the empirical fluid mechanical models used in the frequency domain model for nonlinear resistance and mass reactance may be required. A scale model treatment design that could be tested on the Universal Propulsion Simulator vehicle was proposed.

Clark, L.↗

Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

NASA Discipline Cardiopulmonary↗