Advancing Our Understanding of System Availability through the PV Fleet Performance Data Initiative

The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.

inverter availability↗

Relating Aerial Infrared Thermography Defects to Photovoltaic Performance: Preprint

In this research, we examine the relationship between aerial IR defect analysis and photovoltaic (PV) performance data for twelve utility- and commercial-scale solar sites in the United States. To do this, we fuse the site diagram geoJSON's, aerial infrared thermography (aIRT) defect analyses, and associated inverter time series, allowing for a direct comparison between site defects and time series data. Defect analyses were provided by Zeitview, under its Solar Insights platform. Following the data fusion process, we look at the relationship between system performance and aIRT defects. We investigate the relationship between degradation and hotspot defects, as well as the relationship between AC power data and offline strings and misaligned modules. In general, system degradation was not affected by long-term or balance-of-system (BoS) defects as they occurred infrequently in the data set. However, for one system, a near statistically significant relationship (p-value=0.057) was found when comparing the degradation of inverter blocks with several multi-hotspot defects to all other inverter blocks without this particular defect. There was strong alignment when comparing short-term recoverable module defects such as stuck trackers and offline strings to time series data. In general, we found that when an inverter block has more than 80% of modules flagged for one of these defects, its AC power time data is flat-lined and the inverter block is not producing.

aerial inspection↗

Cold Climate Degradation: An Analysis of Double-Axis Tracked, E-W Vertical, and Fixed-Tilt Photovoltaic Deployments in Alaska

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize remote northern communities due to their scalability and affordability. However, a major barrier towards large-scale adoption of PV in cold climates is performance uncertainty under extreme environmental conditions including snowfall, freeze-thaw cycles, and high wind loads. Existing literature on PV degradation rates in the North is relatively limited, with published degradation rates varying between -0.2%/year (Sweden) to -1.3%/year (Scotland). At this workshop, we will present preliminary results on the long-term performance of two diverse photovoltaic sites located in Fairbanks, Alaska at 64.8 degrees N: a monofacial Al-BSF double-axis tracking site maintained by the Cold Climate Housing Research Center (CCHRC), and a bifacial PERC/SHJ E-W vertical and south-facing fixed-tilt site maintained by the Alaska Center Energy and Power (ACEP). CCHRC data has been collected over a period of 15 years, while ACEP site data has been collected over 4 years. Using the degradation analysis tool, RdTools, we will present annual system degradation rates, seasonal performance ratio, and identify potential cold climate failure mechanisms for commercially available PV technologies. This analysis will add to existing literature by directly comparing the performance of multiple PV configurations in Alaska.

bifacial↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗

AI and ML Applications for PV Reliability and System Performance

This poster discusses AI and ML topics in PV reliability and system performance. In particular, automated metadata extraction and QA for fielded solar installations is covered for the PV Fleets Project. Additionally, statistical learning topics for the PVInsight Project are addressed, as well as development of the PV Validation Hub.

algorithm↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

Close Roof Mounted System Temperature Estimation for Compliance to IEC TS 63126

When photovoltaic modules are installed on rooftops the temperature is dependent on both the geographic location and the mounting configuration. If the mounting structure does not provide sufficient air flow in a hot environment, the 98th percential temperature will exceed 70 degrees C which according to IEC TS 63126 requires higher levels of thermal stability testing. However, a simple there is not a clear way to determe which temperature level is needed for a particular location and system design. In this work we identify a relationship between the gap between the rooftop and a module and propose methods to describe minimum gaps for a given location. Because system designs vary in more ways than just the gap, we show how to determine an effective gap which can be simply applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

IEC 63126↗

Solar Photovaltaics Durability and Resilience - A Win-Win

Solar photovoltaics (PV) will play a crucial role in decarbonizing the electrical grid and limit the effects of detrimental climate change. Long lifetimes of PV installations are a win-win situation, as it not only reduces carbon emissions directly through avoidance of fossil fuel emissions but also indirectly, as it reduces the demand of needed materials and potentially recycling. However, during their decades-long lifetime expectations installations are also more commonly exposed to extreme weather events. Building durable solar system to withstand extreme weather events is essential in the electrification of the economy and will save lives, particularly when they power critical infrastructure such as hospitals. As more PV is installed in regions prone to extreme weather events, high-quality materials, installation and monitoring practices can mitigate risk. Evaluating resilience requires combined computational, analytical, and experimental capabilities that are best leveraged by teams working across multiple disciplines.

durability↗

Power Loss and Safety Risks - Recoverable vs. Non-Recoverable?

This presentation presents an update to the PV fleet analysis on PV system degradation. A median system degradation of -0.7 %/year was found for almost 5000 inverter traces. No significant difference between silicon and CdTe technologies were found. Systems with trackers showed a slightly higher degradation. Silicon technologies such as PERC and heterojunction showed degradation similar to conventional technologies but also showed different degradation mechanisms. To achieve long lifetimes early failure must be minimized through qualification testing. Rapid detection during normal life is important as is the control of bill of materials in modules.

degradation↗

Trends in Field and Laboratory Performance of Photovoltaic Modules and Materials

This DuraMAT project intends to identify bill of materials (BOM) and/or process control measures for photovoltaic modules with representative failure modes as informed by accelerated and field tests to guide next steps in module and material design. We have begun work to identify correlation between module field performance and accelerated testing results by cross-comparing a module database of accelerated test results with a module database of fielded systems. We have identified fielded systems with degraded performance, and intend to compare this to the results observed in certification and qualification testing. We also intend to apply lessons and observations from accelerated tests to the field, where it may be possible to mitigate or avoid degradation in the field.

DuraMAT↗

Life after 30 years - a PV system in Colorado

The PV system consisted of 155 monocrystalline Si Arco M53 panels, installed in 1987. 80 were installed on a fixed tilt rack, and 75 on 5 separate dual-axis passive trackers. The system was decommissioned in 2017 due a campus re-design and building expansion at the Platte River Power Authority (PPRA) site. Prior to decommissioning a site visit established the following failure type observations: EVA browning (100%), cracked cells (60%), and cracked wires or grommets (9%, or more if replacements were made selectively on cracked parts). EVA browning is typical in modules of this vintage, whereas the occurrence of so many cracked cells is surprising and is likely weather-related. The fairly frequent occurrence of cracked wires and grommets serves as a reminder that accelerated testing of these components is important for goals of low-cost 50-year energy generation. In smaller numbers, thermal effects (7%), bent frames (1%), and cell corrosion (<1%) were observed. A sample of 20 modules was selected and brought to NREL for in-depth characterization. Because baseline measurements were not available using the nameplate rating, which can be inaccurate, revealed a mean module sample degradation of 0.7 %/year. Sporadic production data during the 30 years determined a system degradation rate closer to 1.2 %/year. Subsequently, four of these modules were re-mounted outdoors at NREL and are now approaching a total lifetime of 34 years.

durability↗

Photovoltaic Module Imaging for Hail Damage Assessment with Multi-Year Follow Up

Outdoor-aged photovoltaic modules that have experienced golf-ball sized hail are characterized by flash testing and photoluminescence, electroluminescence, thermal, and ultraviolet fluorescence imaging. These measurements were performed immediately after the hailstorm and then again after another two years and four years in the field. The modules originally experienced different ranges of hail damage with some having cracks on approximately half of the cells and some having few to no cracked cells. Flash testing shows that the hail-damaged modules with the most cracked cells have 3 to 4% less power than those with the least damage. After four more years in the outdoor climate of Golden, Colorado since the hailstorm, all of the modules still exhibit similar relative power and amounts of cell cracking, suggesting that the hail damage has only initially reduced power but has not yet increased the degradation rate.

electroluminescence↗

Loss Factor Assessment in the 8GW PV Fleet Performance Data Initiative

This presentation is divided into the following sections: (1) photovoltaics (PV) current and future deployment; (2) the PV Fleet Performance Data Initiative; (3) fleet degradation trends; (4) high-efficiency module performance; (5) other system loss factors; and (6) conclusions.

deployment↗

Silicon Heterojunction Field Performance

The market share of silicon heterojunction (SHJ) modules are expected to increase in the following years. The presentation discusses field performance of SHJ and compares it to other high-efficiency modules. In-depth materials characterization is used to understand the origins of degradation in these type of modules.

ENGINEERING,SOLAR ENERGY↗

Chapter 3: Reliability and Durability Testing Today

In year 2022 the Institute of Applied Sustainability to the Built Environment (ISAAC) of the Department of Environment Constructions and Design (DACD) of the University of Applied Sciences and Arts of Southern Switzerland (SUPSI) celebrates an important anniversary: 40 years of Ticino Solare (TISO), the first photovoltaic system in Europe connected to the grid back in 1982. The Institute of Applied Sustainability to the Built Environment (ISAAC) intends to realize a commemorative/perspective publication on the TISO. The publication will be available starting from the beginning of September 2022 and will be distributed on the occasion of the WCPEC in Milan (26-30 September 2022) and then be available for online download at https://pvlab.solar/wp-content/uploads/2022/10/TISO_Catalogo_Web.pdf.

durability↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗