Chapter 3: Reliability and Durability Testing Today

Abstract

In year 2022 the Institute of Applied Sustainability to the Built Environment (ISAAC) of the Department of Environment Constructions and Design (DACD) of the University of Applied Sciences and Arts of Southern Switzerland (SUPSI) celebrates an important anniversary: 40 years of Ticino Solare (TISO), the first photovoltaic system in Europe connected to the grid back in 1982. The Institute of Applied Sustainability to the Built Environment (ISAAC) intends to realize a commemorative/perspective publication on the TISO. The publication will be available starting from the beginning of September 2022 and will be distributed on the occasion of the WCPEC in Milan (26-30 September 2022) and then be available for online download at https://pvlab.solar/wp-content/uploads/2022/10/TISO_Catalogo_Web.pdf.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jordan, Dirk (ORCID:0000000221837489), Caccivio, Mauro. 2022-09-01. Chapter 3: Reliability and Durability Testing Today. https://www.osti.gov/biblio/2527269

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The "PVLib" of Degradation: PVDeg

The Photovoltaic (PV) industry constantly aims for lower costs through higher-efficiency cells, improved module designs, and improvements in durability. This leads to the use of new materials, designs, and manufacturing processes, and not always with a sufficient amount of durability testing. To help drive down costs there is a desire to create modules that will last for up to 50 years of service life. To accomplish this, every degradation mode and mechanism must be identified and either eliminated or otherwise mitigated. This involves the extrapolation of laboratory results to the field conditions. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. While the basic equations used to model degradation are sometimes very simple, the full analysis involves calculations are cumbersome but ubiquitous for many degradation processes. A simplified, modeling framework to accomplish these repetitive processes will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this talk, we will describe our progress creating the open-source tool PVDeg. This tool can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. PVDeg simplifies many of the common foundational computational operations for obtaining meteorological data and using it to generate a model of the PV deployment. This prediction tool repository also contains various degradation models as well as a library of material parameters suitable for estimating the durability assessment of materials and components. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database, and other weather sources, to perform geospatial degradation analysis in the US and worldwide. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry. During the talk, we will provide the PVPMC attendees the opportunity to interact with the tool via a Google Collab tutorial they can run on their phones or laptops.

durability↗

Solar Photovaltaics Durability and Resilience - A Win-Win

Solar photovoltaics (PV) will play a crucial role in decarbonizing the electrical grid and limit the effects of detrimental climate change. Long lifetimes of PV installations are a win-win situation, as it not only reduces carbon emissions directly through avoidance of fossil fuel emissions but also indirectly, as it reduces the demand of needed materials and potentially recycling. However, during their decades-long lifetime expectations installations are also more commonly exposed to extreme weather events. Building durable solar system to withstand extreme weather events is essential in the electrification of the economy and will save lives, particularly when they power critical infrastructure such as hospitals. As more PV is installed in regions prone to extreme weather events, high-quality materials, installation and monitoring practices can mitigate risk. Evaluating resilience requires combined computational, analytical, and experimental capabilities that are best leveraged by teams working across multiple disciplines.

durability↗

Life after 30 years - a PV system in Colorado

The PV system consisted of 155 monocrystalline Si Arco M53 panels, installed in 1987. 80 were installed on a fixed tilt rack, and 75 on 5 separate dual-axis passive trackers. The system was decommissioned in 2017 due a campus re-design and building expansion at the Platte River Power Authority (PPRA) site. Prior to decommissioning a site visit established the following failure type observations: EVA browning (100%), cracked cells (60%), and cracked wires or grommets (9%, or more if replacements were made selectively on cracked parts). EVA browning is typical in modules of this vintage, whereas the occurrence of so many cracked cells is surprising and is likely weather-related. The fairly frequent occurrence of cracked wires and grommets serves as a reminder that accelerated testing of these components is important for goals of low-cost 50-year energy generation. In smaller numbers, thermal effects (7%), bent frames (1%), and cell corrosion (<1%) were observed. A sample of 20 modules was selected and brought to NREL for in-depth characterization. Because baseline measurements were not available using the nameplate rating, which can be inaccurate, revealed a mean module sample degradation of 0.7 %/year. Sporadic production data during the 30 years determined a system degradation rate closer to 1.2 %/year. Subsequently, four of these modules were re-mounted outdoors at NREL and are now approaching a total lifetime of 34 years.

durability↗