JPSS-4 VIIRS Version 2 at-Launch Relative Spectral Response Characterization

The JPSS-4 VIIRS sensor, the last in a JPSS program that will eventually span some 25+ years of on-orbit data collection, has completed its pre-launch test program. The test program included measurements for characterizing the VIIRS relative spectral response (RSR) in support of the Sensor and Environmental Data Records that will be generated from JPSS-4 VIIRS on-orbit observations after launch. Subject matter experts of the Government Team’s VIIRS DAWG have analyzed the VIIRS spectral measurements and produced the VIIRS spectral characterization, in the form of band averaged and supporting detector level RSR for each VIIRS band. The characterization is based upon the analysis of independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements. The SpMA and GLAMR measurements for reflectance bands (DNBLGS and DNBMGS, I1-I3, M1-M11) were combined to produce a “fused” RSR. For emissive bands (I4, I5, M12-M16), the SpMA measurements provide the entire characterization. The effort has led to the VIIRS Version 2 RSR product, the official at-launch RSR characterization for the JPSS-4 VIIRS mission, which is currently slated to be the next launch (expected Fall 2027) of the JPSS program. As expected, the JPSS-4 RSR are a close match to those of JPSS-3 and JPSS-2 (NOAA-21) VIIRS, while showing some spectral position and shape differences with SNPP and JPSS-1 (NOAA-20) VIIRS. An assessment on compliance with spectral performance metrics finds that VIIRS bandaverage RSR are compliant on nearly all metrics, with only a single minor exception. The Version 2 RSR will be available under EAR99 restrictions to the science community on the restricted access NASA Sharepoint.

SDR

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang

JPSS-3 VIIRS Version 2 at-Launch Relative Spectral Response Characterization

The JPSS-3 VIIRS sensor has completed its pre-launch test program including measurements for characterizing the VIIRS relative spectral response (RSR) in support of the Sensor and Environmental Data Records (SDR and EDR, resp.) that will be generated from VIIRS on-orbit observations. Government team subject matter experts of the VIIRS DAWG have analyzed the VIIRS spectral measurements and produced the VIIRS spectral characterization, in the form of band-average and supporting detector level RSR for each VIIRS band. The characterization is based upon the analysis of independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements. The SpMA and GLAMR measurements for reflectance bands (DNB LGS and MGS, I1-I3, M1-M11) were combined to produce a “fused” RSR. For emissive bands (I4, I5, M12-M16), the SpMA measurements provide the characterization. The effort has led to the VIIRS Version 2 RSR release, the official at-launch RSR characterization for the JPSS-3 VIIRS mission. The JPSS-3 RSR are a close match to those of JPSS-2. An assessment on compliance with spectral performance metrics finds that VIIRS band-average RSR are compliant on nearly all metrics, with only a single minor exception. The Version 2 RSR release is available under EAR99 restrictions to the science community on the restricted access NASA Sharepoint.

Chris Moeller

Landsat 9 Mission Update and Status

Landsat 9 is currently undergoing testing at the integrated observatory level in preparation for launch from Vandenberg Air Force Base in 2021. Landsat 9 will replace Landsat 7 in orbit, 8 days out of phase with Landsat 8. Landsat 9 is largely a copy of Landsat 8 in terms of instrumentation, with an Operational Land Imager (OLI), model #2 and a Thermal Infrared Sensor (TIRS), model #2. The TIRS-2 is more significantly changed from TIRS with increased redundancy, as well as changes to the telescope baffling to improve stray light control and a revised scene select mirror encoder mechanism. Data quality of the Landsat 9 instruments is comparable to, or better than the Landsat 8 ones, with an increase to 14 bits of data transmitted and more detailed pre-launch characterization for OLI-2, and with more detailed characterization of the TIRS-2 pre-launch, in addition to the improved stray light control. The performance of the two instruments is summarized and compared to that of the Landsat 8 instruments.

Brian Markham

LANDSAT 9: Mission Status and Prelaunch Instrument Performance Characterization and Calibration

Landsat 9 is currently under development as a joint effort between NASA and the United States Geological Survey (USGS). Landsat 9 is largely a rebuild of Landsat 8 and has the same two sensors, an Operational Land Imager (OLI) and a Thermal InfraRed Sensor(TIRS). The OLI-2 on Landsat 9, being built by Ball Aerospace, has completed its pre-launch characterization and calibration and is scheduled to be delivered in the summer of 2019. The TIRS-2, with improved stray light performance and increased redundancy for improved reliability, is being built by Goddard Space Flight Center. TIRS-2is undergoing testing through Spring 2019 and is also scheduled for summer2019 delivery. Several improvements to the characterization of both instruments have been incorporated into the testing plan, including improved spectral and radiometric characterization. The instruments will then be integrated onto the spacecraft being built by Northrop Grumman Innovation Systems (NGIS). The mission is targeted to launch as early as December 2020 on an Atlas V.

Landsat

Continuous Calibration Improvement in Solar Reflective Bands: Landsat 5 Through Landsat 8

Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements have been made in the OLI instrument relative to prior Landsat instruments: pushbroom imaging which provides substantially improved Signal-to-Noise Ratio (SNR), spectral bandpasses refinement to avoid atmospheric absorption features, 12 bit data resolution to provide a larger dynamic range that limits the saturation level, a set of well-designed onboard calibrators to monitor the stability of the sensor. Some of these changes such as refinements in spectral bandpasses compared to earlier Landsats and well-designed on-board calibrator have a direct impact on the improved radiometric calibration performance of the instrument from both the stability of the response and the ability to track the changes. The on-board calibrator lamps and diffusers indicate that the instrument drift is generally less than 0.1% per year across the bands. The refined bandpasses of the OLI indicate that temporal uncertainty of better than 0.5% is possible when the instrument is trended over vicarious targets such as Pseudo Invariant Calibration Sites (PICS), a level of precision that was never achieved with the earlier Landsat instruments. The stability measurements indicated by on-board calibrators and PICS agree much better compared to the earlier Landsats, which is very encouraging and bodes well for the future Landsat missions too.

Nischal Mishra

Pre-Launch Calibration Methods of OCI on the Pace Mission

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. This paper describes the methods used for pre-launch calibration of OCI and considerations to ensure the combination of Ground Support Equipment (GSE) and instrument effects meet uncertainty and performance requirements. General considerations when designing a calibration campaign are also discussed.

oci

Initial Look at the Results From the Prelaunch Characterization Campaign of OCI on the Pace Mission

Scheduled for launch in January 2024, the Phytoplankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. This paper describes the results of the prelaunch test campaign of the OCI Flight Unit. The measured OCI flight unit performance exceeded requirement thresholds in all critical areas. Overall, the performance of the OCI is excellent, and will allow the PACE science team to meet its science objectives.

Calibration

PACE OCI Flight Unit Pre-launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE

Pace Oci Flight Unit Pre-Launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.