Search NASA⌕ Search

Engineering topics

Kandlakunta, Praneeth

Publications and source records attributed to Kandlakunta, Praneeth.

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4th Big Data for Nuclear Power Plants Workshop 2023

The Ohio State University and Idaho National Laboratory organized the 4 th Big Data for Nuclear Power Plants Workshop in November, 2023 in Columbus, Ohio. Workshop topics were chosen to understand the challenges and gaps that need to be addressed to maximize the impact of data on the nuclear industry, as well as the associated applications and risks. Discussions were focused around six specific application areas: Operation and Maintenance; Machine Learning in Nuclear Materials and Advanced Manufacturing; Cybersecurity; High-Performance Computing and Massive Computation; Big Data and Digital Twins; and Nuclear Non-Proliferation. The opportunities, challenges, and risks identified in the six focus areas explored in this workshop are diverse, but some common themes emerge, such as the importance of data integrity, quality, coverage, privacy, and traceability. Big data and AI/ML tools can be leveraged to reduce costs, optimize human tasking, and reduce human error across various application areas. In order for the nuclear industry to benefit from big data and advanced analytic capabilities, it is essential to address challenges and risks, such as data privacy, model reliability, and computational resource availability. Learning from other industries that have successfully implemented big data and AI/ML technologies, like the aerospace industry, can help the nuclear industry successfully integrate these technologies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Longevity evaluation of SiC based alpha voltaic batteries with surface alpha sources

The alpha emitting actinide 241 Am is electrodeposited on the surface of the Pt electrode of in-house fabricated SiC Schottky diodes. With 17 nCi 241 Am directly coated on the top of a device, the 2-pi geometry yields a high energy (5.486 MeV) and a long-term irradiation accumulating to a high fluence (1.6 × 10 9 alpha particles’ infusion/month). The forward, reverse I/V, and dark current, are periodically measured to monitor key characteristics of device durability for any sign of degradation over time. The direct deposition of actinides on the surface of the device also enables the evaluation of radiation damage through alpha particles’ energy spectroscopic performance, which shows a clear spectrum degradation that can be reversed by optical excitation of the device prior to spectrum acquisition. As an analytical aide, the device performance is also simulated by Allpix 2 . Lastly, this study provides an insight into the durability of 4H-SiC as an energy converter option for alpha-voltaic batteries and the survivability in the other harsh environment found in nuclear fuel cycle, high energy physics, fission, fusion, and space exploration where rad-hard sensors are required.

Americium↗

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large area vertical Ga 2 O 3 Schottky diodes for X-ray detection

In this work, the Schottky barrier diodes were fabricated from a bulk Sn-doped (001) n-type Ga 2 O 3 substrate with a Si-doped epitaxial layer grown by hydride vapor phase epitaxy (HVPE), which demonstrate a good response to X-rays. Circular metal contacts with diameters ranging from 50 to 1500 um and square metal contacts ranging from 100 X 100 to 1600 X 1600 um 2 were deposited on the wafer. The devices were characterized for their electrical performance including forward current–voltage (FIV), reverse current–voltage (RIV), and capacitance-voltage (CV) measurements. The best device showed a breakdown voltage of –804 V and the devices tested had an average ideality of 1.12. The devices exhibited a clear response to X-rays even at zero bias with an experimentally observed response time 1.03 s and a linear response of detector signal to the X-ray dose rate. The experimentally observed device response time improved to 0.25 s when bias voltage is applied. The device also survived a long-term stability test of over 2 h under a constant X-ray irradiation. The sensitivity and the lower limit of detection for X-ray by Ga2O3 epitaxial Schottky detectors were discussed and determined as 43.5 C/mGy cm –2 at –200 V and 8.31 nGy Air /s, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗