Search NASA⌕ Search

Engineering topics

Kemp, G. E.

Publications and source records attributed to Kemp, G. E..

Soft x-ray power diagnostics for fusion experiments at NIF, Omega, and Z facilities

Here, in this Review Article, we discuss a range of soft x-ray power diagnostics at inertial confinement fusion (ICF) and pulsed-power fusion facilities. This Review Article describes current hardware and analysis approaches and covers the following methods: x-ray diode arrays, bolometers, transmission grating spectrometers, and associated crystal spectrometers. These systems are fundamental for the diagnosis of ICF experiments, providing a wide range of critical parameters for the evaluation of fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

Increased Ion Temperature and Neutron Yield Observed in Magnetized Indirectly Driven $\mathrm{D_2}$-Filled Capsule Implosions on the National Ignition Facility

Here, the application of an external 26 Tesla axial magnetic field to a D 2 gas-filled capsule indirectly driven on the National Ignition Facility is observed to increase the ion temperature by 40% and the neutron yield by a factor of 3.2 in a hot spot with areal density and temperature approaching what is required for fusion ignition. The improvements are determined from energy spectral measurements of the 2.45 MeV neutrons from the D(d, n) 3 He reaction, and the compressed central core B field is estimated to be ~4.9 kT using the 14.1 MeV secondary neutrons from the D(T, n) 4 He reactions. The experiments use a 30 kV pulsed-power system to deliver a ~ 3 μs current pulse to a solenoidal coil wrapped around a novel high-electrical-resistivity AuTa 4 hohlraum. Radiation magnetohydrodynamic simulations are consistent with the experiment

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Magnetized Indirect Drive Project on the National Ignition Facility

A new project is underway at the National Ignition Facility with the goal of applying a seed magnetic field to the fusion fuel in an indirect drive hohlraum implosion and quantifying the effect on the hot-spot temperature, shape and neutron yield. Magnetizing fusion fuel is calculated to reduce heat loss from the implosion core by constraining the motion of electrons and fusion-generated alpha particles; this can improve the chances of achieving high-gain fusion in a laboratory plasma. Here, we describe the goals of this project and the significant scientific and technological challenges which must be overcome for this project to succeed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing plasma magnetization in inertial confinement fusion implosions using secondary deuterium-tritium reactions

Diagnosing plasma magnetization in inertial confinement fusion implosions is important for understanding how magnetic fields affect implosion dynamics and to assess plasma conditions in magnetized implosion experiments. Secondary deuterium–tritium (DT) reactions provide two diagnostic signatures to infer neutron-averaged magnetization. Magnetically confining fusion tritons from deuterium–deuterium (DD) reactions in the hot spot increases their path lengths and energy loss, leading to an increase in the secondary DT reaction yield. In addition, the distribution of magnetically confined DD-triton is anisotropic, and this drives anisotropy in the secondary DT neutron spectra along different lines of sight. Implosion parameter space as well as sensitivity to the applied B-field, fuel ρR, temperature, and hot-spot shape will be examined using Monte Carlo and 2D radiation-magnetohydrodynamic simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation studies of the interaction of laser radiation with additively manufactured foams

The interaction of laser radiation with foams of various porosities and low densities has been the subject of several numerical and experimental studies. In all cases, the modeling of low-Z under-dense foams as uniform gases of equivalent average density using standard radiation-hydrodynamics codes has resulted in heat-front velocities that are considerably faster than those observed experimentally. It has been theoretically conjectured that this difference may be attributed to the breakdown of the foam’s morphology, leading to a dynamics of filament expansion where the ion and electron energy partitions are significantly different from those calculated using the uniform gas model. We found that 3D computer simulations employing a disconnected representation of the foam’s microstructure which allowed for the dynamics of foam element heating, expansion, and stagnation largely supported the theoretical picture. Simulations using this model for laser experiments on under-dense 2 mg cc -1 SiO 2 aerogel foams reproduced the experimental data fairly well. We used the validated model in simulations of low-density structured foam-like materials (produced via additive manufacturing) with a variety of morphologies. We found that the log-pile configurations were consistent with the analytical propagation model of Gus’kov et al. Further validation of the model was obtained by simulating experiments performed at the Jupiter Laser Facility using the log-pile and octet-truss foam morphologies. Simulations of the foam-laser interaction using a wave propagation code showed that the microstructure was able to enhance stimulated Brillouin scattering (SBS) by concentrating the light energy into density holes. In turn, this promotes laser filamentation, reducing SBS and bringing the predicted values closer to the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High yield polar direct drive fusion neutron sources at the National Ignition Facility

Polar direct drive neutron source experiments were performed at the National Ignition Facility showing substantial improvement in total neutron yield and efficiency of conversion of laser energy to fusion output. Plastic capsules 3–4 mm in diameter were filled with 1.5 mg/cc of deuterium–tritium (DT) fuel and imploded with laser beam pointing and defocus designed to compensate for polar asymmetry introduced by the facility beam entrance angles. Radiation-hydrodynamics simulations were employed to optimize the multi-dimensional laser and target parameter space, within facility and target fabrication constraints. Ensembles of 1D simulations tuned to match the outputs of early shots in the series were used to design subsequent shots in the series. This allowed the later shots to be designed based on empirically motivated sensitivities to laser and target input parameters, while eliminating the need to explicitly model phenomena such as hydrodynamic instabilities and nonlinear laser–plasma interactions. Additionally, one experiment with a 3.0 mm diameter CH capsule produced 13.6 kJ (4.81 × 10 15 DT neutrons) from a laser input below the NIF optics damage threshold at 585 kJ, 328 TW. Two experiments with 4.0 mm capsules produced 31.3 and 33.6 kJ of fusion output (1.11 × 10 16 and 1.19 × 10 16 DT neutrons) with 1.10 MJ, 390 TW and 1.26 MJ, 425 TW of laser input, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

47 OTHER INSTRUMENTATION↗

Demonstration of Geometric Effects and Resonant Scattering in the X-Ray Spectra of High-Energy-Density Plasmas

In a plasma of sufficient size and density, photons emitted within the system have a probability of being reabsorbed and reemitted multiple times—a phenomenon known in astrophysics as resonant scattering. This effect alters the ratio of optically thick to optically thin lines, depending on the plasma geometry and viewing angle, and has significant implications for the spectra observed in a number of astrophysical scenarios, but has not previously been studied in a controlled laboratory plasma. In this work, we demonstrate the effect in the x-ray spectra emitted by cylindrical plasmas generated by high power laser irradiation, and the results confirm the geometrical interpretation of resonant scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized continuum x-ray emission from laser-generated plasma

We study continuum x-ray emission from hot plasma at the National Ignition Facility (NIF). We find that the x-ray yield in the multi-keV photon energy range is larger in Ti than in Ag or Au. This apparent paradox is due to Ti K-shell vacancies generated by the extraordinary energy density achieved by the NIF lasers. This is supported by direct observations of large continuum enhancement above the Ti K-series limit due to both free–bound (recombination) emission and strong Ly α (H-like) emission. Detailed calculations agree well with our measurements and support our conclusions. <!--/abstract content--><!--fulltext content--> X-ray emission from matter pervades the universe and plays an important role in the high-energy density (HED) regime (~10 5 J/cm 3 ). For example, the emission and absorption of x-rays controls the thermal state and evolution of stellar interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗