Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

Abstract

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Harris, C. D., Kemp, G. E., Schneider, M. B., Widmann, K., Rubery, M. S., May, M. J.. 2021-03-01. Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments. https://doi.org/10.1063/5.0035584

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗