Frustraum 1100 experimental campaign on the national ignition facility
Not Available
Engineering topics
Publications and source records attributed to Rubery, M. S..
Not Available
Abstract Fusion ignition by inertial confinement requires compression and heating of the fusion fuel to temperatures in excess of 5 keV and densities exceeding hundreds of g/cc. In August 2021, this scientific milestone was surpassed at the National Ignition Facility (NIF), when the Lawson criterion for ignition was exceeded generating 1.37MJ of fusion energy (Abu-Shawareb et al 2022 Phys. Rev. Lett. 129 075001), and then in December 2022 target gain >1 was realized with the production of 3.1MJ of fusion energy from a target driven by 2.0MJ of laser energy (Abu-Shawareb et al 2024 Phys. Rev. Lett. 132 065102). At the NIF, inertial confinement fusion research primarily uses a laser indirect drive in which the fusion capsule is surrounded by a high-Z enclosure (‘hohlraum’) used to convert the directed laser energy into a symmetric x-ray drive on the capsule. Precise measurements of the plasma conditions, x-rays, γ -rays and neutrons produced are key to understanding the pathway to higher performance. This paper discusses the diagnostics and measurement techniques developed to understand these experiments, focusing on three main topics: (1) key diagnostic developments for achieving igniting plasmas, (2) novel signatures related to thermonuclear burn and (3) advances to diagnostic capabilities in the igniting regime with a perspective toward developments for intertial fusion energy.
An indirect-drive inertial fusion experiment on the National Ignition Facility was driven using 2.05 MJ of laser light at a wavelength of 351 nm and produced 3.1±0.16 MJ of total fusion yield, producing a target gain G=1.5±0.1 exceeding unity for the first time in a laboratory experiment [Phys. Rev. E 109, 025204 (2024)]. Herein we describe the experimental evidence for the increased drive on the capsule using additional laser energy and control over known degradation mechanisms, which are critical to achieving high performance. Further, improved fuel compression relative to previous megajoule-yield experiments is observed. Novel signatures of the ignition and burn propagation to high yield can now be studied in the laboratory for the first time.
Not Available
As fusion experiments at the National Ignition Facility (NIF) approach and exceed breakeven, energy from the burning capsule is predicted to couple to the gold walls and reheat the hohlraum. For example, on December 5, 2022, experiment N221204 exceeded target breakeven, historically achieving 3.15 MJ of fusion energy from 2.05 MJ of laser drive; for the first time, energy from the igniting capsule reheated the hohlraum beyond the peak laser-driven radiation temperature of 313 eV to a peak of 350 eV, in less than half a nanosecond. This reheating effect has now been unambiguously observed by the two independent Dante calorimeter systems across multiple experiments, and is shown to result from reheating of the remnant tungsten-doped ablator by the exploding core, which is heated by alpha deposition.
Here, in this Review Article, we discuss a range of soft x-ray power diagnostics at inertial confinement fusion (ICF) and pulsed-power fusion facilities. This Review Article describes current hardware and analysis approaches and covers the following methods: x-ray diode arrays, bolometers, transmission grating spectrometers, and associated crystal spectrometers. These systems are fundamental for the diagnosis of ICF experiments, providing a wide range of critical parameters for the evaluation of fusion performance.
A fused silica Cherenkov detector was used to measure deuterium-tritium (DT) gammas during a set of 52 direct-drive cryogenic experiments performed at OMEGA. The detector was calibrated using the 4.4 MeV$\gamma$ from the first-excited state of carbon, which is produced when 14-MeV DT neutrons impinge upon a carbon puck. An approximate DT $\gamma$ spectrum as well as neutron yields from a standard neutron time-of-flight detector at OMEGA were used to calculate a DT $\gamma$-to-neutron branching ratio of (8.42 ± 2.84 ) x 10 -5 . Assuming an excited-state to ground-state ratio of 2.1:1, the measurement detailed in this work results in an approximate ground state only$\gamma$-to-neutron branching ratio of 2.72 x 10 -5 . So, this value is somewhat lower than accelerator-based measurements of the ground-state DT $\gamma$ only.
Establish the level of reproducibility of NIF iron opacity shots, quantify to-date improvements in data quality through, e.g. background reduction, improved signal, and improved analysis methods, and formalize the approach that will be taken in the future to compare NIF data, Z data, and theory.
We report previously, hydrodynamic simulations suggested that precisely tailoring the capsule ablator thickness (shimming) could counterbalance cylindrical Hohlraum Legendre P 4 drive asymmetries at the capsule in laser indirect drive implosions. As a result, the stagnated deuterium–tritium (DT) fuel areal density P 4 asymmetry is reduced, potentially resulting in a nuclear yield increase. Inflight radiographs of various level of shimmed capsules with plastic (CH) ablators showed that shims can indeed control the in-flight capsule shell P 4 asymmetry, with a linear sensitivity to shim amplitude that is close to analytic estimates and simulations. Furthermore, the stagnated DT fuel areal density P 4 asymmetry inferred from downscattered neutron imaging was reduced when the capsule shim was applied, in agreement with simulations matching the inflight shell asymmetry. A nuclear yield improvement via shim was not observed, as predicted, likely due to implosion instabilities and as built capsule shim deviations from an ideal P 4 shape.
Not Available
An inertial fusion implosion on the National Ignition Facility, conducted on August 8, 2021 (N210808), recently produced more than a megajoule of fusion yield and passed Lawson's criterion for ignition [Phys. Rev. Lett. 129, 075001 (2022)]. Here we describe the experimental improvements that enabled N210808 and present the first experimental measurements from an igniting plasma in the laboratory. Ignition metrics like the product of hot-spot energy and pressure squared, in the absence of self-heating, increased by ~ 35%, leading to record values and an enhancement from previous experiments in the hot-spot energy (~ 3×), pressure (~ 2×), and mass (~ 2×). These results are consistent with self-heating dominating other power balance terms. The burn rate increases by an order of magnitude after peak compression, and the hot-spot conditions show clear evidence for burn propagation into the dense fuel surrounding the hot spot. These novel dynamics and thermodynamic properties have never been observed on prior inertial fusion experiments.
Graded metal pushered single shell (PSS) capsules are predicted to be a viable alternative to low-Z capsule indirect drive inertial confinement fusion (ICF) implosions for achieving high fusion yields [MacLaren et al., Phys. Plasmas 28, 122710 (2021)]. The first experiments with Be/Cr-graded metal PSS capsules indicate that the implementation of the principle design feature, the graded density inner metal layer, has succeeded in producing a stable implosion with performance in agreement with predictions. With 50% Cr concentration in the pusher, PSS capsules have greater than ~2× higher shell densities during stagnation for enhanced core confinement and radiation trapping at ~35% lower shell implosion velocities than low-Z capsules. High-energy >30 keV inflight shell radiography recorded 215 km/s implosion velocities and show that implosion Legendre mode P 2 asymmetry can be tuned via inner-to-outer beam wavelength separation, similar to other implosions. Shell radiographs and neutron core images show similar P 2 asymmetry, suggesting no symmetry swings between peak implosion velocity and stagnation times. Despite the modest implosion velocities, gas-filled deuterium–tritium capsule implosions generate 10 15 neutron yields at relatively modest core ion temperatures of 2.75 keV, indicating that in spite of the high-density inner layer, the implosions have been stabilized by the design density gradient. When compared with hydrodynamic simulations, the measured yield-over-simulated is 35% due to fuel–pusher mix and other perturbations such as the capsule fill tube. Finally, simple analytical scalings of hot spot pressure and neutron yield show that PSS implosions reach similar performance at lower implosion velocities and higher shell densities to low-Z ICF capsules.
Explore the source record for details and available documents.
Here, the R-matrix analysis of A = 5 nuclear systems has been partially validated by applying the technique to the 5 Li system and comparing the predicted γ-ray spectrum with historical data. R-matrix analysis of the similar 5 He system was then used to predict the γ-ray spectral shape for the deuterium-tritium (DT) reaction. The resulting spectra have been used in the analysis of DT implosions on the Omega laser where the γ-ray interaction rate was measured by a gas Cherenkov detector. Comparison of predictions to experiment confirmed the presence of both 16.75 and ≈ 13 MeV γ-ray contributions; analysis, using R-matrix spectra, yielded a ratio of γ-ray emission from a transition to the intermediate excited state to that from a transition to the ground state of (2.1 ± 0.4):1, substantiating the first spectral measurement of the DT fusion γ ray in an inertial fusion environment.
We report γ-ray emission from 12 C and 13 C samples irradiated with deuterium-tritium fusion neutrons was experimentally measured at the Omega Laser Facility and at the Ohio University Edwards Accelerator Laboratory. The intent of these measurements was to determine the feasibility of using 13 C-based plastic ablators with embedded 12 C layers for “dark mix” diagnosis of inertial confinement fusion implosions. Spectrally resolved measurements at Ohio University identified significant 4.44-MeV γ-ray emission from the 13 C(n, 2nγ) 12 C-L1 reaction channel. The recorded 4.44-MeV 13 C signal was compared against emission from an identically irradiated 12 C target with known 12 C(n, n'γ) 12 C-L1 cross section, which resulted in an average 13 C(n, 2nγ) 12 C-L1 cross section of 117 ± 17 mb over the incident neutron energy distribution range from 14.4 to 15.8 MeV. Integrated 13C γ -ray signals above 2.9 MeV recorded with the Gas Cherenkov Detector at Omega exceeded MCNP6.1 predictions by a factor of 3. The additional signal was attributed to 4.44-MeV γs resulting in an inferred 13 C(n, 2nγ) 12 C-L1 cross section of 95 ± 11 mb at 14.1-MeV average incident neutron energy. As a result, the 13 C-based “dark mix” diagnostic concept was deemed infeasible.
Double shell capsule implosions are an alternative approach to achieving alpha heating on the National Ignition Facility. Current machining techniques construct the outer shell as two hemispheres that are glued together, and the deuterium and tritium (DT) liquid inside the inner shell will be injected by a fill tube. These features introduce asymmetries and jetting that may disrupt the confinement of the DT fuel if not carefully controlled. Simulations indicate that in order to achieve high yields in the laboratory, these features as well as susceptibility to the Rayleigh–Taylor instability (RTI) must be mitigated. Furthermore, due to uncertainties in computational models and the expense of using the best physics models at adequate resolution in three dimensions, our computational modeling must be constrained by experiments. We report on the results of recent hydrogrowth radiography and dual-axis keyhole experiments with double shell targets that have been used to evaluate our modeling of the outer shell joint as well as the impacts of high-energy x-ray preheat that strongly impacts RTI growth. Our simulations show good agreement with the experimental data and inform several important modeling choices.
The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.
DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.