Search NASA⌕ Search

Engineering topics

May, M. J.

Publications and source records attributed to May, M. J..

At least 19 records

Electron collisional excitation cross-section measurements and modeling for select Ni-like to Ge-like gold transitions

We have experimentally determined the electron collisional excitation cross-sections for several 3d→4f and 3d→5f excitations in Ni- to Ge-like Au at energies of ~ 0.4, 1, 2, and 3 keV above threshold energy, E T , for the 3d→4f excitations ( E T ~ 2.5 keV) and ~ 0.2, 1, and 2 keV above threshold energy for the 3d→5f excitations ( E T ~ 3.3 keV). The cross-section measurements are possible by using the GSFC micro-calorimeter to record emission spectra from beam plasmas created in the Livermore EBIT-I electron beam ion trap. The cross-sections are experimentally determined from the ratio of the measured intensities of the collisionally excited lines to the intensities of the radiative recombination lines in monoenergetic electron distribution EBIT-I plasmas. The effects of polarization and Auger processes in the beam plasmas are accounted for in the cross-section determination. Experimentally determined cross-sections are compared with those from HULLAC, DWS, and FAC calculations. Finally, the measurements exhibit significant differences with the calculations of these excitation cross-sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

47 OTHER INSTRUMENTATION↗

FY20 LLNL Experimental Programs at Omega

In Fiscal Year 2020 (FY20), Lawrence Livermore National Laboratory’s (LLNL’s) High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted numerous campaigns on the OMEGA and OMEGA-EP (EP) laser systems. This was the 22ndyear of National Lab collaborative experiments at OMEGA since the Nova Laser at LLNL shut down in 1999, building upon prior collaborations. In FY20overall,these LLNL programs led 375target shots, with 166shots using just the OMEGA laser system and209 shots using just the EP laser system. Approximately 34% of the total number of shots (35OMEGA shots and 93EP shots) supported the Indirect Drive Inertial Confinement Fusion Campaign. The remaining 66% (131OMEGA-only shots and 116EP-only shots) were dedicated to experiments for High-Energy-Density Physics.Highlights of the various HED and ICF-ID campaigns are summarized in the following reports.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗

Investigation of high X-ray conversion efficiency Kr filled gas sources at the National Ignition Facility

In this work, we report on the performance of high x-ray fluence Kr K-shell sources that are being developed for high energy density experiments. These targets are 4.1 mm in diameter 4.4 mm tall hollow epoxy tubes having a 40 μm thick wall holding 1.5 atm of Kr gas. For these shots, the National Ignition Facility laser delivered a nominally constant total energy of ≈750 kJ of 351 nm (3ω) light at the three power levels [e.g., ≈120 (low), ≈145 (medium), and ≈210 TW (high)]. The Kr K-shell (E photon = 8–20 keV) x-ray radiant intensity and radiant energy (kJ/sr) of these sources were found to increase as a function of laser power but began to plateau at the highest laser power. The Kr K-shell radiant energy increased from ≈1 kJ/sr at ≈120 TW to ≈2 kJ/sr at ≈210 TW. Radiation hydrodynamics simulations predict radiant energies to be always higher than these measurements. The increase in K-shell emission is attributed to its strong dependence on the electron temperature. Electron temperature distributions were inferred from measured Heα and Lyα line emission through the use of a genetic algorithm and Scram modeling. The inferred temperatures from the experiment are 20% to 30% higher than those predicted from modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the one-dimensional imager of neutrons (ODIN) for neutron response functions at the Sandia Z facility

The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 μm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-μm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 10 12 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. The experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential Improvements for the One-Dimensional Imager of Neutrons at the Sandia Z Facility

Understanding the neutron source shape is critical for improving Magnetized Liner Inertial Fusion (MagLIF) implosions at the Sandia Z machine. Neutron source-shape measurements for MagLIF are, however, challenging due to the yields, extended axial source regions, x-ray backgrounds and physical shock waves produced by MagLIF sources. Initial tests of a slit neutron imager for 1- dimensional neutron imaging along the axial dimension of MagLIF implosions have shown that a rolled-slit aperture and CR-39 plastic detector can image the neutron production along the axial dimension. In this whitepaper, we suggest straightforward improvements to the neutron imager design that will allow significantly improved signal-to-noise performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high intensity X-ray sources at the National Ignition Facility

Laser heated plasmas have provided recently some of the most powerful and energetic nanosecond length laboratory sources of x-ray photons (E photon = 1–30 keV). The highest x-ray to laser conversion is currently accessible by using underdense (n e ~ 0.25 n c ) plasmas since optimal laser coupling is obtained in millimeter scale targets. The targets can have conversion efficiencies of up to 10%. Furthermore, several types of targets can be used to produce underdense plasmas: metal lined cylindrical cavities, gas pipes, and most recently nano-wire foams. Both the experimental and simulation details of these high intensity x-ray sources are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500–2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ~20 μm thickness have been performed. X-ray yields of up to ~1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ~100 μm FWHM, with ~350 ps pulse duration during the peak emission stage. Lastly, these results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Replicating the Z iron opacity experiments on the NIF

Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3 . Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of a Long Pulse X-ray Source at the National Ignition Facility

A long duration high fluence x-ray source has been developed at the National Ignition Facility (NIF). The target was a 14.4 mm tall, 4.1 mm diameter, epoxy walled, gas filled pipe. Approximately 1.34 MJ from the NIF laser was used to heat the mixture of (55:45) Kr:Xe at 1.2 atm (~5.59 mg/cm 3 ) to emit in a fairly isotropic radiant intensity of 400–600 GW/sr from the E photon = 3–7 keV spectral range for a duration of ≈ 14 ns. Lastly, the HYDRA simulated radiant intensities were in reasonable agreement with experiments but deviated at late times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electron impact collisional excitation cross sections of Ni to Ge-like gold

We have measured the collisional excitation cross sections for the 3d→4f and 3d→5f excitations in Au ions near the Ni-like charge state by using beam plasmas created in the Livermore electron beam ion trap EBIT-I. The cross sections have been experimentally determined at approximately 1, 2 and 3 keV above the threshold energy, ET, for the 3d→4f excitations (ET ~2.5 keV) and at approximately 0.1, 1 and 2 keV above the threshold energy for the 3d→5f excitations (ET ~3.3 keV). The cross section measurements were made possible by using the GSFC x-ray microcalorimeter at the Livermore EBIT facility. The absolute cross sections are determined from the ratio of the intensity of the collisionally excited bound-bound transitions to the intensity of the radiative recombination lines produced in EBIT-I plasmas. The effects of polarization and Auger decay channels are accounted for in the cross section determination. Measured cross sections are compared with those from HULLAC, DWS and FAC calculations. Finally, the measurements demonstrate that some errors exist in the calculated excitation cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding reconstructed Dante spectra using high resolution spectroscopy

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-LTE analysis of high energy density Kr plasmas on Z and NIF

We report that multi-keV X-ray radiation sources have a wide range of applications, from biomedical studies and research on thermonuclear fusion to materials science and astrophysics. The refurbished Z pulsed power machine at the Sandia National Laboratories produces intense multi-keV X-rays from argon Z-pinches, but for a krypton Z-pinch, the yield decreases much faster with atomic number Z A than similar sources on the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory. To investigate whether fundamental energy deposition differences between pulsed power and lasers could account for the yield differences, we consider the Kr plasma on the two machines. The analysis assumes the plasma not in local thermodynamic equilibrium, with a detailed coupling between the hydrodynamics, the radiation field, and the ionization physics. While for the plasma parameters of interest the details of krypton’s M-shell are not crucial, both the L-shell and the K-shell must be modeled in reasonable detail, including the state-specific dielectronic recombination processes that significantly affect Kr’s ionization balance and the resulting X-ray spectrum. We present a detailed description of the atomic model, provide synthetic K- and L-shell spectra, and compare these with the available experimental data from the Z-machine and from NIF to show that the K-shell yield behavior versus Z A is indeed related to the energy input characteristics. In conclusion, this work aims at understanding the probable causes that might explain the differences in the X-ray conversion efficiencies of several radiation sources on Z and

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗