Search NASA⌕ Search

Engineering topics

Schneider, M. B.

Publications and source records attributed to Schneider, M. B..

At least 19 records

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Statistical data analysis of x-ray spectroscopy data enabled by neural network accelerated Bayesian inference

Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. Here, we present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.

47 OTHER INSTRUMENTATION↗

X-ray continuum spectroscopy of inertial confinement fusion implosions at the National Ignition Facility

A methodology for measuring x-ray continuum spectra of inertial confinement fusion (ICF) implosions is described. The method relies on the use of ConSpec, a high-throughput spectrometer using a highly annealed pyrolytic graphite crystal , which measures the spectra in the ≃20–30 keV range. Due to its conical shape, the crystal is sagittally focusing a Bragg-reflected x-ray spectrum into a line, which enhances the recorded x-ray emission signal above the high neutron-induced background accompanying ICF implosions at the National Ignition Facility. To improve the overall measurement accuracy, the sensitivity of the spectrometer measured in an off-line x-ray laboratory setting was revised. The error analysis was expanded to include the accuracy of the off-line measurements, the effect of the neutron-induced background, as well as the influence of possible errors in alignment of the instrument to the ICF target. Here we demonstrate how the improved methodology is applied in the analysis of ConSpec data with examples of a relatively low-neutron-yield implosion using a tritium–hydrogen–deuterium mix as a fuel and a high-yield deuterium–tritium (DT) implosion producing high level of the background. In both cases, the shape of the measured spectrum agrees with the exponentially decaying spectral shape of bremsstrahlung emission to within ±10%. In the case of the high-yield DT experiment, non-monotonic deviations slightly exceeding the measurement uncertainties are observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extended X-ray absorption fine structure of dynamically-compressed copper up to 1 terapascal

Abstract Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Investigation of heat transport using directly driven gold spheres

Recently, heat transport was investigated using a directly driven beryllium sphere [Farmer et al., Phys. Plasmas 27, 082701 (2020)]. Models that overly restrict heat transport were rejected. This paper extends work to directly driven gold spheres where radiation loss is more important. Here, gold coated spheres are directly driven at the OMEGA laser facility at intensities of 5×10 14 W/cm 2 . Plasma conditions, laser coupling, and x-ray flux are all measured. Additionally, comparisons to 2D radiation-hydrodynamic simulations are performed. Simulations use three common heat transport models: local transport with flux limiters of f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. It is shown that both the SNB model and f = 0.15 match the measured plasma conditions with the SNB model better capturing the temporal evolution of electron temperature. The f = 0.03 model predicts too low of an electron density and too hot of a temperature. The measured scattered light is roughly 6% of the incident energy, the f = 0.15 and SNB models predict 0.5% uncoupled light, and f = 0.03, 38% uncoupled light. The x-ray fluxes in the f = 0.15 and SNB simulations rise too quickly and are just outside the measurement's error, while the x-ray flux in the f = 0.03 simulation is low by a factor of two-three. For these reasons, the f = 0.03 model is rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗

Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

47 OTHER INSTRUMENTATION↗

Demonstration of Geometric Effects and Resonant Scattering in the X-Ray Spectra of High-Energy-Density Plasmas

In a plasma of sufficient size and density, photons emitted within the system have a probability of being reabsorbed and reemitted multiple times—a phenomenon known in astrophysics as resonant scattering. This effect alters the ratio of optically thick to optically thin lines, depending on the plasma geometry and viewing angle, and has significant implications for the spectra observed in a number of astrophysical scenarios, but has not previously been studied in a controlled laboratory plasma. In this work, we demonstrate the effect in the x-ray spectra emitted by cylindrical plasmas generated by high power laser irradiation, and the results confirm the geometrical interpretation of resonant scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low mode implosion symmetry sensitivity in low gas-fill NIF cylindrical hohlraums

Achieving an efficient capsule implosion in National Ignition Facility indirect-drive target experiments requires symmetric hohlraum x-ray drive for the duration of the laser pulse. This is commonly achieved using two-sided two-cone laser irradiation of cylindrical hohlraums that, in principle, can zero the time average of all spherical harmonic asymmetry modes <6 as well as the time dependence of the usually dominant mode 2. In practice, experimental evidence indicates that maintaining symmetric drive becomes limited late in the pulse due to the inward expansion of the hohlraum wall and outward expansion of the capsule ablator plasmas impairing the propagation of the inner-cone laser beams. This effect is enhanced in hohlraums employing low gas-fill, now used almost exclusively as these provide the highest performing implosions and reduce Stimulated Brillouin and Raman backscatter losses, since the gas plasma provides less back pressure to limit blow-in of the hohlraum wall and capsule ablator plasmas. In order to understand this dynamic behavior, we combined multi-keV X-ray imaging of the wall and imploded fuel plasmas as we changed a single parameter at a time: hohlraum gas-fill, laser outer cone picket energy, radius of high density carbon capsules used, and laser beam polar and azimuthal pointing geometry. In this work, we developed a physics-based multi-parameter experimental scaling to explain the results that extend prior scalings and compare those to radiation hydrodynamic simulations to develop a more complete picture of how hohlraum, capsule, and laser parameters affect pole vs equator drive symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized continuum x-ray emission from laser-generated plasma

We study continuum x-ray emission from hot plasma at the National Ignition Facility (NIF). We find that the x-ray yield in the multi-keV photon energy range is larger in Ti than in Ag or Au. This apparent paradox is due to Ti K-shell vacancies generated by the extraordinary energy density achieved by the NIF lasers. This is supported by direct observations of large continuum enhancement above the Ti K-series limit due to both free–bound (recombination) emission and strong Ly α (H-like) emission. Detailed calculations agree well with our measurements and support our conclusions. <!--/abstract content--><!--fulltext content--> X-ray emission from matter pervades the universe and plays an important role in the high-energy density (HED) regime (~10 5 J/cm 3 ). For example, the emission and absorption of x-rays controls the thermal state and evolution of stellar interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress toward NIF opacity measurements

The opacities of iron and other mid-Z elements help to regulate the transport of energy in the sun. Recent experiments on the Sandia National Laboratories Z machine have shown large discrepancies between the measured and calculated opacities of iron at certain solar conditions. To replicate these opacity measurements a platform is being developed on the National Ignition Facility to measure the opacities of iron and other elements at the same conditions as in the Z experiments. The NIF platform consists of a hohlraum to heat the opacity sample to the desired conditions, a separate backlighter to radiograph the sample, and a spectrometer to give the spectrally resolved opacity. Not only must the opacity be measured but the temperature and density of the sample must also be accurately determined. This platform has now produced its first iron transmission measurements. Overall, these measurements will be presented along with plans for future measurements and details on how the measurements will be improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗