Effect of self-generated magnetic fields on x-ray emission in Kr-filled targets at the National Ignition Facility

We examine the effects of self-generated magnetic fields in a Kr gas pipe x-ray source platform. X-ray emission from Kr plasma is dependent on the plasma conditions, as the ionization state is largely a function of temperature. Magnetic fields are known to limit heat conduction, which increases temperature. We show that the emission in simulations of the gas pipe x-ray source is dependent on how self-generated magnetic fields are modeled. The inclusion of self-generated magnetic fields in simulations more accurately captures the emission of lower energy x-ray emission (L-shell), bringing results closer to experiments. The modeled x-ray emission and self-generated magnetic fields are shown to be particularly sensitive to the inclusion of the Nernst effect in simulations. Severely limiting the Nernst effect leads to a hotter Kr plasma, which can account for the discrepancy seen in earlier studies. By modifying the Nernst effect multiplier, we can achieve better experimental agreement in x-ray emission from gas pipes; the value of the multiplier that leads to the best agreement is dependent on the laser power of the drive. Currently, the suppression factor of the Nernst effect needed for high power drives (PL>200 TW) is more restrictive than what is currently put forward by non-local models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization disequilibrium in K- and L-shell ions

Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray source characterization and sample heating on x-ray diffraction experiments at the National Ignition Facility

X-ray diffraction is a powerful measurement technique for determining material properties, and it is now possible to perform these experiments at pressures exceeding 1 TPa [Rygg et al., Rev. Sci. Instrum. 91, 043902 (2020)] at the National Ignition Facility (NIF). The x-ray source for these experiments is the quasi-monochromatic Heα emission from metal foils heated to multi-keV temperatures. A critical aspect for understanding the sample's thermodynamic state is the amount of heating caused by absorption of the probe x-rays. In this work, we characterize the performance of the Ge foil x-ray source over more than 60 NIF x-ray diffraction experiments. We use this information to constrain the level of diffraction sample heating from the x-ray source and discuss the impact on the thermodynamic state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A polar direct drive liquid deuterium–tritium wetted foam target concept for inertial confinement fusion

We propose a new approach to inertial confinement fusion (ICF) that could potentially lead to ignition and propagating thermonuclear burn at the National Ignition Facility (NIF). The proposal is based upon a combination of two concepts, referred to as polar direct drive and liquid deuterium–tritium wetted foam capsules. With this new concept, 2D radiation hydrodynamic simulations indicate that ICF ignition and propagating thermonuclear burn are possible with the laser power and energy capabilities available today on the NIF.

3D printing↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

Experimental and calculational investigation of laser-heated additive manufactured foams

Foam materials are starting to find application in laser-heated Hohlraums used to drive inertial confinement fusion implosions. Foams made using additive manufacturing (AM) techniques are now available and may have advantages over traditional chemical (aerogel) foams. Here, we present new experimental data on laser-heated AM foams. Samples of four different types of printed AM foams were heated using a single 527 nm laser beam at the Jupiter Laser Facility. The laser pulse was ∼180 J square pulse with an FWHM of 1.6 ns and a peak intensity of 3–4 × 1014 W/cm2. The foam densities ranged from 12 to 93 mg/cc (all supercritical for 527 nm light). We measured the backscattered light (power and spectrum), the transmitted light, side-on x-ray images, and the Ti K-shell emission that was used to infer the time-integrated temperature. The fraction of backscattered light was 6%–15% of the input laser energy. The pure carbon foam sample had less backscatter than a C8H9O3 foam of similar density, which was consistent with multi-fluid calculations that predicted less ion heating for the C8H9O3 foam. The level of backscatter and the thermal front speeds for the AM foams were similar to values measured for stochastic (aerogel) foams under similar conditions.

36 MATERIALS SCIENCE↗