Search NASA⌕ Search

Engineering topics

Kim, Daejin [NETL Site Support Contractor, National Energy Technology Laboratory]

Publications and source records attributed to Kim, Daejin [NETL Site Support Contractor, National Energy Technology Laboratory].

Hydrogen Detection via a Low-Cost Prototype Fiber-Optic Sensing System

The developed low-cost prototype sensing system successfully detects hydrogen concentrations across a wide range, demonstrating immediate feasibility for commercial deployment. Utilizing fiber-optic technology, the system delivers stable, reproducible performance from parts-per-million levels up to 100% pure H2 environments. Environmental and chemical cross-sensitivity evaluations confirm robust selectivity against methane and temperature changes, establishing its readiness for near-term commercialization.

fiber-optic H2 sensor↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80 °C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80°C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer↗