Search NASA⌕ Search

Engineering topics

Koehler, Katrina Elizabeth

Publications and source records attributed to Koehler, Katrina Elizabeth.

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma and Decay Energy Spectroscopy Measurements of Trinitite

We report gamma-ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics techniques. Our gamma spectroscopy and DES measurements are compared to other published results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

SEE LANL: Student Educational Experience at LANL [PowerPoint]

SEE LANL is designed to provide university students a hands-on nuclear safeguards training course based on the courses given to all IAEA inspectors. It aims to encourage networking and collaborations between university students/professors and laboratory staff, introduce students to the variety of safeguards-related technical work at LANL and provides early-career technical staff an opportunity to teach. Further details on the program are provided.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗