State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yoho, Michael Duncan, Garner, Scott Edward, Koehler, Katrina Elizabeth, Vo, Duc Ta, Croce, Mark Philip. 2020-07-21. Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge. https://doi.org/10.1016/j.nima.2020.164056

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗