Search NASA⌕ Search

Engineering topics

Lauer, H. V., Jr.

Publications and source records attributed to Lauer, H. V., Jr..

At least 19 records

Dividing the Concentrator Target From the Genesis Mission

The Genesis spacecraft, launched in 2001, traveled to a Lagrangian point between the Earth and Sun to collect particles from the solar wind and return them to Earth. However, during the return of the spacecraft in 2004, the parachute failed to open during descent, and the Genesis spacecraft crashed into the Utah desert. Many of the solar wind collectors were broken into smaller pieces, and the field team rapidly collected the capsule and collector pieces for later assessment. On each of the next few days, the team discovered that various collectors had survived intact, including three of four concentrator targets. Within a month, the team had imaged more than 10,000 fragments and packed them for transport to the Astromaterials Acquisition and Curation Office within the ARES Directorate at JSC. Currently, the Genesis samples are curated along with the other extraterrestrial sample collections within ARES. Although they were broken and dirty, the Genesis solar wind collectors still offered the science community the opportunity to better understand our Sun and the solar system as a whole. One of the more highly prized concentrator collectors survived the crash almost completely intact. The Genesis Concentrator was designed to concentrate the solar wind by a factor of at least 20 so that solar oxygen and nitrogen isotopes could be measured. One of these materials was the Diamond-on-Silicon (DoS) concentrator target. Unfortunately, the DoS concentrator broke on impact. Nevertheless, the scientific value of the DoS concentrator target was high. The Genesis Allocation Committee received a request for approximately 1 cm(sup 2) of the DoS specimen taken near the focal point of the concentrator for the analysis of solar wind nitrogen isotopes. The largest fragment, Genesis sample 60000, was designated for this allocation and needed to be precisely cut. The requirement was to subdivide the designated sample in a manner that prevented contamination of the sample and minimized the risk of losing or breaking the precious requested sample fragment. The Genesis curator determined that the use of laser scribing techniques to "cut" a precise line and subsequently cleave the sample (in a controlled break of the sample along that line) was the best method for accomplishing the sample subdivision. However, there were risks, including excess heating of the sample, that could cause some of the implanted solar wind to be lost via thermal diffusion. Accidentally breaking the sample during the handling and cleaving process was an additional risk. Early in fiscal year 2013, to address this delicate, complicated task, the ARES Directorate assembled its top scientists to develop a cutting plan that would ensure success when applied to the actual concentrator target wafer; i.e., to produce an approximately 1 cm(sup 2) piece from the requested area of the wafer. The team, subsequently referred to as the JSC Genesis Tiger Team, spent months researching and testing parameters and techniques related to scribing, cleaving, transporting, handling, and holding (i.e., mounting) the specimen. The investigation required considerable "thinking outside the box," and many, many trials using nonflight wafer analogs. After all preliminary testing, the following method was adopted as the final cutting plan. It was used in two final end-to-end practice runs before being used on the actual flight target wafer. The wafer was oriented on the laser cutting stage with the 100 and 010 directions of the wafer parallel to the corresponding X and Y directions of the cutting stage. The laser was programed to scribe 31 lines of the appropriate length along the Y stage direction. The programed scribe lines were separated by 5 micron in the X direction. The laser parameters were set as follows: (1) The laser power was 0.5 watts; (2) each line consisted of 50 passes, with the Z position being advanced 5 micron per pass; and (3) 30 s would elapse before the next line was scribed to allow for wafer cool down from any possible heating via the laser. The ablated material that "stuck" in the "scribe-cut" was removed from the "cut" using an ultrasonic micro-tool. After all the ablated silicon was removed from the wafer, the wafer was repositioned in exactly the same orientation on the laser stage. The laser was focused using the bottom of the wafer channel, and the 31-line scribing pattern described above was reprogrammed using the Z position of the groove bottom as the starting Z value instead of the top wafer surface, which was used previously. Upon completion of the second set of scribes, the ultrasonic micro-tool was again used to clean out the cut. The wafer was remounted on the stage in exactly the same orientation as before. The laser was again focused on the bottom of the groove. This time, however, the laser was.programed to scribe only one line down the exact center of the channel. The final scribe line consisted of 100 passes with a Z advance of 5 micron per pass and with the laser power set at 0.5 watts. As mentioned above, the final cutting plan was practiced in two end-to-end trials using non-flight, triangular-shaped silicon wafers similar in size and orientation to the actual DOS 60000 target sample. The actual scribing of the triangular-shaped wafers required scribing two lines and cleaving (i.e. scribe-cleave, then scribe-cleave) to obtain the piece requested for allocation. Early in December 2012, after many months of experiments and practicing and perfecting the techniques and procedures, the team successfully subdivided the Genesis DoS 60000 target sample, one of the most scientifically important samples from the Genesis mission (figure 2). On December 17, 2012, the allocated piece of concentrator target sample was delivered to the requesting principal investigator.The cutting plan developed for the subdivision of this sample will be used as the model for subdividing future requested Genesis flight wafers (appropriately modified for different wafer types).

Lauer, H. V., Jr.↗

Plan for Subdividing Genesis Mission Diamond-on-Silicon 60000 Solar Wind Collector

NASA's Genesis solar wind sample return mission experienced an off nominal landing resulting in broken, albeit useful collectors. Sample 60000 from the collector is comprised of diamond-like-carbon film on a float zone (FZ) silicon wafer substrate Diamond-on-Silicon (DOS), and is highly prized for its higher concentration of solar wind (SW) atoms. A team of scientist at the Johnson Space Center was charged with determining the best, nondestructive and noncontaminating method to subdivide the specimen that would result in a 1 sq. cm subsample for allocation and analysis. Previous work included imaging of the SW side of 60000, identifying the crystallographic orientation of adjacent fragments, and devising an initial cutting plan.

Burkett, Patti J.↗

A Possible Organic Contribution to the Low Temperature CO2 Release Seen in Mars Phoenix Thermal and Evolved Gas Analyzer Data

Two of the most important discoveries of the Phoenix Mars Lander were the discovery of approx.0.6% perchlorate [1] and 3-5% carbonate [2] in the soils at the landing site in the martian northern plains. The Thermal and Evolved Gas Analyzer (TEGA) instrument was one of the tools that made this discovery. After soil samples were delivered to TEGA and transferred into small ovens, the samples could be heated up to approx.1000 C and the gases that evolved during heating were monitored by a mass spectrometer. A CO2 signal was detected at high temperature (approx.750 C) that has been attributed to calcium carbonate decomposition. In addition to this CO2 release, a lower temperature signal was seen. This lower temperature CO2 release was postulated to be one of three things: 1) desorption of CO2, 2) decomposition of a different carbonate mineral, or 3) CO2 released due to organic combustion. Cannon et al. [3] present another novel hypothesis involving the interaction of decomposition products of a perchlorate salt and calcium carbonate.

Archer, P. D. Jr.↗

The Mars Phoenix Thermal Evolved-Gas Analysis: The Role of an Organic Free Blank in the Search for Organics

The Thermal Evolved-Gas Analyzer (TEGA) instrument onboard the 2007 Phoenix Lander will perform differential scanning calorimetry (DSC) and evolved-gas analysis of soil samples collected from the surface. Data from the instrument will be compared with Mars analog mineral standards, collected under TEGA Mars-like conditions to identify the volatile-bearing mineral phases [1] (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) found in the Martian soil. Concurrently, the instrument will be looking for indications of organics that might also be present in the soil. Organic molecules are necessary building blocks for life, although their presence in the ice or soil does not indicate life itself. The spacecraft will certainly bring organic contaminants to Mars even though numerous steps were taken to minimize contamination during the spacecraft assembly and testing. It will be essential to distinguish possible Mars organics from terrestrial contamination when TEGA instrument begins analyzing icy soils. To address the above, an Organic Free Blank (OFB) was designed, built, tested, and mounted on the Phoenix spacecraft providing a baseline for distinguishing Mars organics from terrestrial organic contamination. Our objective in this report is to describe some of the considerations used in selecting the OFB material and then report on the processing and analysis of the final candidate material

Lauer, H. V., Jr.↗

Formation of "Chemically Pure" Magnetite from Mg-Fe-Carbonates Implications for the Exclusively Inorganic Origin of Magnetite and Sulfides in Martian Meteorite ALH84001

Magnetite and sulfides in the black rims of carbonate globules in Martian meteorite ALH84001 have been studied extensively because of the claim by McKay et al. that they are biogenic in origin. However, exclusively inorganic (abiotic) processes are able to account for the occurrence of carbonate-sulfide-magnetite assemblages in the meteorite. We have previously precipitated chemically zoned and sulfide-bearing carbonate globules analogous to those in ALH84001 (at less than or equal to 150 C) from multiple fluxes of variable-composition Ca-Mg-Fe-CO2-S-H2O solutions. Brief heating of precipitated globules to approx. 470 C produced magnetite and pyrrhotite within the globules by thermal decomposition of siderite and pyrite, respectively. We have also shown that morphology of magnetite formed by inorganic thermal decomposition of Fe-rich carbonate is similar to the morphology of so-called biogenic magnetite in the carbonate globules of ALH84001. Magnetite crystals in the rims of carbonate globules in ALH84001 are chemically pure [Note: "Chemically pure" is defined here as magnetite with Mg at levels comparable or lower than Mg detected by [8] in ALH84001 magnetite]. A debate continues on whether or not chemically pure magnetite can form by the thermal decomposition of mixed Mg-Fe-carbonates that have formed under abiotic conditions. Thomas-Keprta et al. argue that it is not possible to form Mg-free magnetite from Mg-Fe-carbonate based on thermodynamic data. We previously suggested that chemically pure magnetite could form by the thermal decomposition of relatively pure siderite in the outer rims of the globules. Mg-Fe-carbonates may also thermally decompose under conditions conducive for formation of chemically pure magnetite. In this paper we show through laboratory experiments that chemically pure magnetite can form by an inorganic process from mixed Mg-Fe-carbonates.

Golden, D. C.↗

Thermal and Evolved Gas Analysis of Geologic Samples Containing Organic Materials: Implications for the 2007 Mars Phoenix Scout Mission

The Thermal and Evolved Gas Analyzer (TEGA) instrument scheduled to fly onboard the 2007 Mars Phoenix Scout Mission will perform differential scanning calorimetry (DSC) and evolved gas analysis (EGA) of soil samples and ice collected from the surface and subsurface at a northern landing site on Mars. We have been developing a sample characterization data library using a laboratory DSC integrated with a quadrupole mass spectrometer to support the interpretations of TEGA data returned during the mission. The laboratory TEGA test-bed instrument has been modified to operate under conditions similar to TEGA, i.e., reduced pressure (e.g., 100 torr) and reduced carrier gas flow rates. We have previously developed a TEGA data library for a variety of volatile-bearing mineral phases, including Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates. Here we examine the thermal and evolved gas properties of samples that contain organics. One of the primary objectives of the Phoenix Scout Mission is to search for habitable zones by assessing organic or biologically interesting materials in icy soil. Nitrogen is currently the carrier gas that will be used for TEGA. In this study, we examine two possible modes of detecting organics in geologic samples; i.e., pyrolysis using N2 as the carrier gas and combustion using O2 as the carrier gas.

Lauer, H. V., Jr.↗

Thermal Characterization of Fe3O4 Nanoparticles Formed from Poorly Crystalline Siderite

Increasing interest in environmental geochemistry has led to the recognition that crystals with sizes in the nanometer range (e.g., colloids and nanoscale precipitates) and poorly crystalline compounds (e.g., ferrihydrites) may comprise the majority of reactive mineral surface area near the Earth s surface. When the diameters of individual particles are in the range of 100 nm or less, the surface energy contribution to the free energy modifies phase stability. This results in stabilization of polymorphs not normally encountered in the macrocrystal domain. These phases potentially have very different surface-site geometries, adsorptive properties, and growth mechanisms, and exhibit size-dependent kinetic behavior. Thus nanophases dramatically modify the physical and chemical properties of soils and sediments. In a more general sense, the characteristics of nanocrystals are of intense technological interest because small particle size confers novel chemical, optical, and electronic properties. Thus, nanocrystalline materials are finding applications as catalytic substrates, gas phase separation materials, and even more importantly in the field of medicine. This is an opportune time for mineral physicists working on nanocrystalline materials to develop collaborative efforts with materials scientists, chemists, and others working on nanophase materials of technological interest (e.g., for magnetic memories). Our objective in this study was to synthesize submicron (<200 nm) magnetite and to study their thermal and particle size properties.

Lauer, H. V., Jr.↗

Evidence for exclusively inorganic formation of magnetite in Martian meteorite ALH84001

Magnetite crystals produced by terrestrial magnetotactic bacterium MV-1 are elongated on a [111] crystallographic axis, in a so-called truncated hexa-Octahedral shape. This morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes). A subpopulation of magnetite crystals associated with carbonate globules in Martian meteorite ALH84001 is reported to have this morphology, and the observation has been taken as evidence for biological activity on Mars. In this study, we present evidence for the exclusively inorganic origin of [111]-elongated magnetite crystals in ALH84001. We report three-dimensional(3-D) morphologies for approx.1000 magnetite crystals extracted from: (1) thermal decomposition products of Fe-rich carbonate produced by inorganic hydrothermal precipitation in laboratory experiments; (2) carbonate globules in Martian meteoriteeALH84001; and (3) cells of magnetotactic bacterial strain MV-1. The 3-D morphologies were derived by fitting 3-D shape models to two-dimensional bright-field transmission-electron microscope (TEAM) images obtained at a series of viewing angles. The view down the {110} axes closest to the [111] elongation axis of magnetite crystals ([111]x{110) not equal to 0) provides a 2-D projection that uniquely discriminates among the three [111]-elongated magnetite morphologies found in these samples: [111]-elongated truncated hexaoctahedron ([111]-THO), [111]-elongated cubo-octahedron ([111]-ECO), and [111]-elongated simple octahedron ([111]-ESO). All [111] -elongated morphologies are present in the three types of sample, but in different proportions. In the ALH84001 Martian meteorite and in our inorganic laboratory products, the most common [111]-elongated magnetite crystal morphology is [111]-ECO. In contrast, the most common morphology for magnetotactic bacterial strain MV-1 is [111]-THO. These results show that: (1) the morphology of [111]-elongated magnetite crystals associated with the carbonate globules in Martian meteorite ALH84001 is replicated by an inorganic process; and (2) the most common crystal morphology for biogenic (MV-1) magnetite is distinctly different from that in both ALH84001 and our inorganic laboratory products. Therefore, [111]-elongated magnetite crystals in ALH84001 do not constitute, as previously claimed, a robust biosignature and, in fact, an exclusively inorganic origin for the magnetite is fully consistent with our results. Furthermore, the inorganic synthesis method, i.e., the thermal decomposition of hydrothermally precipitated Fe-rich carbonate, is a process analogue for formation of the magnetite on Mars. Namely, precipitation of carbonate globules from carbonate-rich hydrothermal solutions followed at some later time by a thermal pulse, perhaps in association with meteoritic impact or volcanic processes on the Martian surface.

Golden, D. C.↗

Morphological Evidence for an Exclusively Inorganic Origin for Magnetite in Martian Meteorite ALH84001

The origin of magnetite crystals in Martian Meteorite ALH84001 is the focus of a debate about the possibility of past (and present) life on Mars. McKay et al. originally suggested that some of the magnetite crystals associated with carbonate globules in Martian Meteorite ALH84001 are biogenic in ori-gin, because they are single magnetic domain, free of crystalline defects, chemically pure, and coexist with other metastable phases in apparent disequilibrium. Thomas-Keprta et al. reported that a subpopulation of magnetite crystals (approx. 25%) associated with carbonate globules in ALH84001 and magnetite crystals produced by magnetotactic bacterial strain MV-1 have similar morphologies with crystal elongation along the [111] crystallographic axis that they describe as "truncated hexa-octahedral" ([111-THO]) magnetite. Along with several other properties, the [111]-THO morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes), so that the presence of [111]-THO magnetite in ALH84001 may be evidence for past life on Mars.

Golden, D. C.↗

Thermal Analysis of Acicular Shaped Magnetite

We are in the process of developing a database on the thermal properties of well-characterized Martian analog materials in support of future Mars surface missions. The database contains the thermal behaviors of these analog materials under reduced and Earth ambient pressures. Magnetite in planetary materials has received considerable attention in recent years since the identification of fine grain single-domain magnetite in Martian meteorite ALH84001 and their possible link to past life on Mars (i.e., possible biominerals of magnetotactic bacteria). Because of its possible importance to Mars science, we report here the thermal properties of magnetite particles with acicular morphology, i.e., needle-shaped magnetite. Acicular shaped magnetite can be commercially produced from goethite (FeOOH) as the starting material via a H2 reduction process. However, instead of using this process or procedure, we report here on the thermal characterization of acicular magnetite formed under reducing conditions from well-characterized needle-shaped goethite at low temperature in controlled CO-CO2 1-bar atmosphere gas mixing furnaces.

Lauer, H. V., Jr.↗

The Search for Water and Other Volatile-bearing Phases on Mars: Mauna Kea Volcano as an Analog

Over the past 5 years, we have conducted field studies on the summit cones of Mauna Kea Volcano in Hawaii. Basaltic materials on several of these summit cones have been significantly altered by hydrothermal activity, whereas other summit cones have not undergone extensive aqueous alteration. These summit cones provide an important environment to study analogs of Martian surface alteration materials and analog surface processes (i.e., hydrothermal alteration, palagonitization. In on-going research, we have characterized the thermal and evolved gas behaviors of volatile-bearing reference minerals at reduced pressures in support of TEGA. We have expanded those studies to characterize the thermal and evolved gas behaviors of Mauna Kea samples as an analog for Mars surface materials. These samples were chosen for two reasons. First, many have chemical and spectral properties similar to what we see from remote sensing data from the Martian surface. Second, these samples have a range of mineralogical and chemical properties, ranging from simple to very complex; hence it will be challenging to characterize their thermal and evolved gas behaviors and to provide a context for their geological evolution. However, these types of studies are absolutely critical to understanding relevant geologic processes on Mars during robotic missions to the surface.

Ming, D. W.↗

Differential Scanning Calorimetry of Volatile-Bearing Iron Minerals Under Mars-Like Pressures: New Insights Into Energetics and Mechanisms of Thermal Decomposition

In this study, we have examined the thermal decomposition of two volatile-bearing iron minerals, in particular, lepidocrocite (gamma-FeOOH) and siderite (FeCO3), under Mars-like pressures. Both minerals exhibit different enthalpic events during their decomposition at reduced atmospheric pressures when compared to those at ambient pressure. These differences in energetics are related to the mechanisms of thermal decomposition at Mars-like pressures. Such knowledge regarding the thermal stability of volatile-bearing minerals on Mars will provide useful information for planetary surface processes.

Lin, I.-C.↗

Thermal and Evolved Gas Analyses at Reduced Pressures: A Mineral Database for the Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) may be important phases on the surface of Mars. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to detect and identify volatile-bearing phases in the Martian regolith. The TEGA instrument is composed of a differential scanning calorimetry (DSC) interfaced with an evolved gas analyzer (EGA). The EGA consists of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO, and H2O abundances. The sample chamber in TEGA operates at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Essentially no information exists on the effects of reduced pressure on the thermal properties of volatile-bearing minerals. Here we present a database for the thermal behavior of volatile-bearing phases under reduced pressure conditions.

Lauer, H. V., Jr.↗

Thermal and Evolved Gas Analysis of Hydromagnesite and Nesquehonite: Implications for Remote Thermal Analysis on Mars

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) may be important phases on the surface of Mars. In order to characterize these potential phases the Thermal Evolved-Gas Analyzer (TEGA), which was onboard the Mars Polar Lander, was to have performed differential scanning calorimetry (DSC) and evolved-gas analysis of soil samples collected from the surface. The sample chamber in TEGA operates at about 100 mbar (approximately 76 torr) with a N2, carrier gas flow of 0.4 seem. Essentially, no information exists on the effects of reduced pressure on the thermal properties of volatile-bearing minerals. In support of TEGA, we have constructed a laboratory analog for TEGA from commercial instrumentation. We connected together a commercial differential scanning calorimeter, a quadruple mass spectrometer, a vacuum pump, digital pressure gauge, electronic mass flow meter, gas "K" bottles, gas dryers, and high and low pressure regulators using a collection of shut off and needle valves. Our arrangement allows us to vary and control the pressure and carrier gas flow rate inside the calorimeter oven chamber.

Lauer, H. V., Jr.↗