Search NASASearch

Engineering topics

Lem, J. D.

Publications and source records attributed to Lem, J. D..

Results of Skylab medical experiment M171-metabolic activity

The primary objective of the experiment was to determine whether man's metabolic effectiveness while performing mechanical work was progressively altered by exposure to the space environment. The secondary objective was to evaluate the M171 bicycle ergometer as an in-flight crew personal exerciser. This manuscript is the report of the third (Skylab 4) manned mission and a summary of what was learned from all three Skylab manned missions about the physiological response to exercise during and after periods of 28 days, 59 days, and 84 days of weightlessness, respectively.

Michel, E. L.

Ergometer

The bicycle ergometer was designed for use in experiments M171 and M093 and for use in optional exercise by the crewmen. The ergometer allows a crewman to exercise in zero-gravity using either his hands or his feet. It provides a precisely calibrated and, if needed, a programmable standard of work rate for the crewman. The ergometer operates in any of three selectable modes. The set heart rate mode varies the ergometer work rate, as necessary, to achieve and maintain a preselected heart rate. The sequenced heart rate mode is similar to the set heart rate mode except that the heart rate is programmable through five preset levels with a period of time for each level. The set work rate mode delivers a preset work load to the subject.

Lem, J. D.

Metabolic analyzer

The metabolic analyzer was designed to support experiment M171. It operates on the so-called open circuit method to measure a subject's metabolic activity in terms of oxygen consumed, carbon dioxide produced, minute volume, respiratory exchange ratio, and tidal volume or vital capacity. The system operates in either of two modes. (1) In Mode I, inhaled respiratory volumes are actually measured by a piston spirometer. (2) In Mode II, inhaled volumes are calculated from the exhaled volume and the measured inhaled and exhaled nitrogen concentrations. This second mode was the prime mode for Skylab. Following is a brief description of the various subsystems and their operation.

Lem, J. D.

Body temperature measuring system (M171)

The body temperature probe is used in support of experiment M171 to determine if crewmen are storing heat following exercise and to monitor crew health in case of illness.

Lem, J. D.

Exerciser

The Mark I exerciser which was added for the second and third Skylab missions, was used for a number of arm and leg exercises. This unit is a modified version of a commercial device. This is an iso-kinetic, or constant velocity, exerciser which retards the speed at which the user is allowed to move. The user applies a maximum effort and the device automatically varies the opposing resistance to maintain speed of translation at a constant preselected value.

Lem, J. D.

Results of Skylab medical experiment M171: Metabolic activity

The experiment was conducted to establish whether man's ability to perform mechanical work would be progressively altered as a result of exposure to the weightless environment of space flight. The Skylab crewmen exercised on a bicycle ergometer at workloads approximating 25, 50, and 75 percent of their maximum aerobic capacity. The physiological parameters monitored were respiratory gas exchange, blood pressure, and vectorcardiogram/heart rate. The results of these tests indicate that the crewmen had no significant decrement in their responses to exercise during their exposure to zero gravity. The results of the third manned Skylab mission (Skylab 4) are presented and a comparison is made of the overall results obtained from the three successively longer Skylab manned missions. The Skylab 4 crewmembers' 84-day in-flight responses to exercise were no worse and were probably better than the responses of the crewmen on the first two Skylab missions. Indications that exercise was an important contributing factor in maintaining this response are discussed.

Michel, E. L.

Skylab biomedical hardware development

The development of hardware to support biomedical experimentation and operations in the Skylab vehicle presented unique technical problems. Designs were required to enable the accurate measurement of many varied physiological parameters and to compensate for zero g such that uninhibited equipment operation would be possible. Because of problems that occurred during the orbital workshop launch, special tests were run and new equipment was designed and built for use by the first Skylab crew. Design concepts used in the development of hardware to support cardiovascular, pulmonary, vestibular, body, and specimen mass measuring experiments are discussed. Additionally, major problem areas and the corresponding design solutions, as well as knowledge gained that will be pertinent for future life sciences hardware development, are presented.

Huffstetler, W. J., Jr.