Search NASA⌕ Search

Engineering topics

Lenardo, B. G.

Publications and source records attributed to Lenardo, B. G..

At least 19 records

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Report from the Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale

These proceedings summarize the program and discussions of the ``Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale'' held on October 25-27 2023 at SLAC National Accelerator Laboratory. This workshop brought together experts from the communities of neutrinoless double-beta decay and dark matter detection, to discuss paths forward for the realization of monolithic experiments with xenon approaching the kilotonne scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for the Migdal effect in liquid xenon with keV-level nuclear recoils

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark matter searches and future Migdal characterization efforts. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Low-Lying Isomeric States in 136 Cs: A New Avenue for Dark Matter and Solar Neutrino Detection in Xenon Detectors

We report on new measurements establishing the existence of low-lying isomeric states in 136 Cs using γ rays produced in 136 Xe(p,n) 136 Cs reactions. Here, two states with O(100) ns lifetimes are placed in the decay sequence of the 136 Cs levels that are populated in charged-current interactions of solar neutrinos and fermionic dark matter with 136 Xe. Xenon-based experiments can therefore exploit a delayed-coincidence tag of these interactions, greatly suppressing backgrounds to enable spectroscopic studies of solar neutrinos and dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan

Through the exploration of fundamental symmetries, and by using nuclei, neutrons, and neutrinos, nuclear physics addresses some of the most profound questions in science. Why does the universe contain so much more matter than antimatter? Are neutrinos their own antiparticles and where do their masses come from? What objects make up the dark matter that is responsible for most of the universe’s mass? Does nature contain more forces than the four we know about? Our Standard Model of nature’s particles and forces is incomplete because it does not answer these questions; new physics, from beyond the Standard Model (BSM) is needed. With that physics not appearing at the high energy frontier, it has become imperative to realize the potential of the burgeoning program of precision nuclear-physics measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast and flexible analysis of direct dark matter search data with machine learning

We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. Furthermore, this technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches

We report liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasimonoenergetic xenon recoils between 39 and 426 keV. We report the xenon recoil responses and their electric field dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2 and 2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high-energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on effective field theory couplings using 311.2 days of LUX data

We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis techniques to account for higher-energy backgrounds was required. With a 3.14$\times10^4$ kg$\cdot$day exposure using data collected between 2014 and 2016, we set 90\% C.L. exclusion limits on non-relativistic EFT WIMP couplings to neutrons and protons, providing the most stringent constraints on a significant fraction of the possible EFT WIMP interactions. Additionally, we report world-leading exclusion limits on inelastic EFT WIMP-nucleon recoils.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective field theory analysis of the first LUX dark matter search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10 -46 cm 2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 10 4 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗