Managing potential environmental and human health risks of lead halide perovskite photovoltaic modules
Not Available
Engineering topics
Publications and source records attributed to Libby, Cara.
Not Available
A critical challenge for the continued expansion of photovoltaics (PV) is to develop technically feasible, inexpensive and environmentally friendly practices for handling and recycling modules at the end of their usable life. The National Renewable Energy Laboratory (NREL) is requested by the Electric Power Research Institute (EPRI) to collect primary data regarding the environmental performance of currently operational PV module recycling facilities in Europe. Very little has been published regarding crystalline silicon (C-Si) module recycling. Thus, much effort will be needed in direct industry outreach, collection of information and other business intelligence strategies similar to NREL's approaches for developing cost models for PV manufacturing. The goal of this work effort is to produce a detailed inventory that accounts for physical (e.g., energy, water, materials) flows through each step of a C-Si recycling process. The inventory (a life cycle inventory, or LCI) shall be designed so that it can be extended to include an accounting of costs for each process step, inputs, etc. This work effort shall leverage prior LCI data collection NREL performed for the United States Department of Energy, Solar Energy Technologies Office, under the auspices of the U.S. contribution to International Energy Agency's Photovoltaics Power Systems (PVPS) Task 12 (Environmental Health and Safety), which SETO nominated NREL to chair. The primary purpose of this work effort is to augment the prior data collection to increase the sample size of manufacturers' primary data in the LCI.
The effect of cracks in solar cells on the long-term degradation of photovoltaic (PV) modules remains to be determined. To investigate this effect in future studies, it is necessary to quantitatively describe the crack features (e.g., length) and correlate them with module power loss. Electroluminescence (EL) imaging is a common technique for identifying cracks. However, it is currently challenging and time-consuming to identify cracks in a large number of EL images and quantify complex crack features by human inspection. This article introduces a fast semantic segmentation method (~0.18 s/cell) to automatically segment cracks from EL images and algorithms to extract crack features. Here we fine-tuned a UNet neural network model using pretrained VGG16 as the encoder and obtained an average F1 score of 0.875 and an intersection over union score of 0.782 on the testing set. With cracks and busbars segmented, we developed algorithms for extracting crack features, including the crack-isolated area, the brightness inside the isolated area, and the crack length. We also developed an automatic preprocessing tool for cropping individual cell images from EL images of PV modules (~0.72 s/module). Our codes are published as open-source an software, and our annotated dataset composed of various types of cells is published as a benchmark for crack segmentation in EL images.
Not Available
Abstract not provided.
Abstract not provided.
Here, we applied time-varying air pressure to a PV module containing newly cracked cells. The test used a new dynamic mechanical acceleration (DMX) apparatus. We applied pressure cycles similar to natural, wind-driven cycles. Compared to standard dynamic mechanical load (DML) tests, we applied much lower pressure (10 Pa to 300 Pa RMS) and many more cycles (one million at each of four pressure levels). We present a case study on a single cell in a commercial module. We monitored electrical continuity loss across cracks using electroluminescence (EL) imaging. 10 Pa pressure cycles caused negligible change. 30 Pa pressure cycles caused permanent damage that continued worsening even after tens of thousands of cycles. After one million 30 Pa cycles, a series of 100 Pa cycles still caused new, permanent damage to existing cracks. 300 Pa cycles caused further worsening and introduced new cracks.
This public dataset contains electroluminescence images of solar cells and crack annotations, which can be used for developing semantic segmentation model to detect cracks in solar modules.
An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six- month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two- tank chloride salt thermal energy storage system.
An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.
The U.S. Department of Energy Solar Energy Technologies Office initiated the Generation 3 Concentrating Solar Power (CSP) program to achieve higher operating temperatures (>700 °C) to enable next-generation CSP high-temperature power cycles such as the supercritical CO 2 (sCO2) Brayton Cycle. Three teams were selected to pursue high-temperature gas, liquid, and solid pathways for the heat-transfer media. Phases 1 and 2, which lasted from 2018 – 2020, consisted of design, modeling, and testing activities to further de-risk each of the technologies and develop a design for construction, commissioning, and operation of a pilot-scale facility in Phase 3 (2021 – 2024). This report summarizes the activities in Phases 1 and 2 for the solid-particle pathway led by Sandia National Laboratories. In Phases 1 and 2, Sandia successfully de-risked key elements of the proposed Gen 3 Particle Pilot Plant (G3P3) by improving the design, operation, and performance of key particle component technologies including the receiver, storage bins, particle-to-sCO2 heat exchanger, particle lift, and data acquisition and controls. Modeling and testing of critical components have led to optimized designs that meet desired performance metrics. Detailed drawings, piping and instrumentation diagrams, and process flow diagrams were generated for the integrated system, and structural analyses of the assembled tower structure were performed to demonstrate compliance with relevant codes and standards. Instrumentation and control systems of key subsystems were also demonstrated. Together with Bridgers & Paxton, Bohannan Huston, and Sandia Facilities, we have completed a 100% G3P3 tower design package with stamped engineering drawings suitable for construction bid in Phase 3.
When cells in a crystalline silicon photovoltaic module crack, packaging materials hold the fragments together. Changes in module temperature cause cell fragments to move, allowing cracked metallization to lose and regain contact. We intentionally cracked cells in commercial PV modules and characterized the modules’ temperature-dependent electroluminescence (EL) response. Here we show that (1) metallization makes contact across cracks in a way that is temperature dependent and (2) this contact is not a function of temperature, but is hysteretic. We expect that any electro-optical characterization made at a single temperature will be misleading as to the effects of cracked cells at different temperatures. And we expect that a single temperature sweep cannot fully characterize the temperature dependence of electro-optical performance of modules with cracked cells.
An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ °C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.