Geographic Assessment of Photovoltaic Module Environmental Degradation Stressors.
Abstract not provided.
Engineering topics
Publications and source records attributed to Libby, Cara.
Abstract not provided.
Abstract not provided.
The rate and type of in-service PV performance degradation vary for different module designs, vintages, and operating climates. The current IEC 61215 module qualification testing standard can be used to identify design and manufacturing flaws that may lead to early life failures, but it was not intended to accurately predict degradation rates in the first 5 to 10 years of a PV plant’s lifetime, nor long-term performance, under varied operating conditions. Correlations between accelerated aging data and real-world degradation data are needed to better predict wear-out degradation in response to environmental stressors, such as elevated temperature, temperature cycling, moisture, wind load, and solar radiation. The PREDICTS2 project aged 36 pristine-condition ‘spare’ modules from a commercial PV power plant in the U.S. Southwest using the IEC 61215 and Qualification Plus (Qual Plus) testing standards. The study is unique in its ability to compare performance degradation data for fielded modules operating outdoors for 6 years in a commercial plant environmental with degradation data for modules of the same make, model and vintage that have been aged artificially in an indoor laboratory. Changes in individual module current-voltage (I-V) curve data were measured before and after the artificial aging process and compared to I-V curve data for the fielded modules. This project advanced the industry’s understanding of how environmental stressors affect performance degradation and established relationships between degradation mechanisms and changes to module electrical parameters and power loss. Improved certainty in degradation rates is expected to be the greatest source of LCOE reduction resulting from this project. Reducing the spread in the degradation rate probability distribution lowers project risk, which translates to lower project financing costs.
Solar photovoltaic (PV) installations must be properly dismantled and any waste treated and disposed of at the end of project life. However, because most of the world's nearly 400 GW of PV systems have been built in the past decade - each expected to operate for between 20 and 30 years-current PV module waste volumes do not yet justify widespread operation of PV recycling facilities. In anticipation of increasing demand however, several recycling companies are evaluating the PV waste market to assess waste-volume growth. Others are pursuing research- and pilot-stage PV module recycling activities. The latter are mostly commercial laminated glass and metal recyclers that process batches of PV modules on a periodic basis. This report describes a recent survey-based evaluation of existing commercial and pilot-scale recycling processes in Europe, and associated life cycle inventory data.
Abstract not provided.
Solar photovoltaic (PV) installations must be properly dismantled and any waste treated and disposed at the end of project life. However, because most of the world's nearly 400 GW of PV systems have been built in the past decade - each expected to operate for between 20 and 30 years - current PV module waste volumes do not yet justify widespread operation of PV recycling facilities. The necessary policies and technologies for recycling PV systems are currently under rapid development. With modifications to the European waste electrical and electronic equipment directive (WEEE 2012/19/EU) in 2012, take back and recycling of PV modules is, in fact, already mandatory in Europe. There, take back and recycling is currently performed in small but annually-increasing quantities. Even though waste treatment is considered part of a module's life cycle, only a few life cycle inventories (LCI) of energy and materials flows are available for the industrial recycling processes that are used today to recycle crystalline silicon-based (c-Si) PV modules. LCI are the data inputs that inform lifecycle assessments which quantify the environmental impacts across the full life cycle of PV modules - from manufacturing and use to end of life. To help progress the industry forward, a survey of European recyclers was performed to characterize existing commercial recycling processes and share associated life cycle inventory data. System Boundaries: The reference unit, or "functional unit" in the vocabulary of life cycle assessment, is defined as the processing of one metric ton of crystalline silicon PV modules in recycling lines for laminated glass, metals, and electronic wastes. Today, all modules are processed in discrete batches, yet not metered at that scale. Thus the process energy for a batch is estimated based on scaled annual production data as well as on input and output streams.
Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.
Abstract A side‐by‐side comparison is made between concentrator photovoltaic module and system direct current aperture efficiency data with a focus on quantifying system performance losses. The individual losses measured/calculated, when combined, are in good agreement with the total loss seen between the module and the system. Results indicate that for the given test period, the largest individual loss of 3.7% relative is due to the baseline performance difference between the individual module and the average for the 200 modules in the system. A basic empirical model is derived based on module spectral performance data and the tabulated losses between the module and the system. The model predicts instantaneous system direct current aperture efficiency with a root mean square error of 2.3% relative. Copyright © 2016 John Wiley & Sons, Ltd.