Search NASA⌕ Search

Engineering topics

Lin, Yuehe

Publications and source records attributed to Lin, Yuehe.

At least 145 records · Page 8

One-step electrochemical deposition of a graphene-ZrO 2 nanocomposite: Preparation, characterization and application for detection of organophosphorus agents

This paper described the preparation, characterization, and electrochemical properties of a graphene-ZrO 2 nanocomposite (GZN) and its application for both the enrichment and detection of methyl parathion (MP). GZN was fabricated using electrochemical deposition and characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), which showed the successful formation of nanocomposites. Due to the strong affinity to the phosphoric group and the fast electron-transfer kinetics of GZN, both the extraction and electrochemical detection of organophosphorus (OP) agents at the same GZN modified electrochemical sensor was possible. The combination of solid-phase extraction and stripping voltammetric analysis allowed fast, sensitive, and selective determination of MP in garlic samples. The stripping response was highly linear over the MP concentrations ranging from 0.5 ng mL -1 to 100 ng mL -1 , with a detection limit of 0.1 ng mL -1 . This new nanocomposite-based electrochemical sensor provides an opportunity to develop a field-deployable, sensitive, and quantitative method for monitoring exposure to OPs.

36 MATERIALS SCIENCE↗

Self assembly of acetylcholinesterase on a gold nanoparticles–graphene nanosheet hybrid for organophosphate pesticide detection using polyelectrolyte as a linker

A nanohybrid of gold nanoparticles (Au NPs) and chemically reduced graphene oxide nanosheets (cr-Gs) was synthesized by in situ growth of Au NPs on the surface of graphene nanosheets in the presence of poly(diallyldimethylammonium chloride) (PDDA), which not only improved the dispersion of Au NPs but also stabilized cholinesterase with high activity and loading efficiency. The obtained nanohybrid was characterized by TEM, XRD, XPS, and electrochemistry. Then an enzyme nanoassembly (AChE/Au NPs/cr-Gs) was prepared by self-assembling acetylcholinesterase (AChE) on Au NP/cr-Gs nanohybrid. An electrochemical sensor based on AChE/Au NPs/cr-Gs was further developed for ultrasensitive detection of organophosphate pesticide. The results demonstrate that the developed approach provides a promising strategy to improve the sensitivity and enzyme activity of electrochemical biosensors.

59 BASIC BIOLOGICAL SCIENCES↗

Microfabricated Renewable Beads-Trapping/Releasing Flow Cell for Rapid Antigen-Antibody Reaction in Chemiluminescent Immunoassay

A filter pillar-array microstructure was coupled with a pneumatic micro-valve to fabricate a reusable miniaturized beads-trapping/releasing flow cell, in which trapping and releasing beads can be conveniently realized by switching the micro-valve. This miniaturized device was suitable to construct automatic fluidic system for “renewable surface analysis”. The renewable surface strategy based on pneumatic micro-valve enabled capture of beads in beads chamber prior to each assay, and release of the used beads after the assay. Chemiluminescent competitive immunoassay of 3,5,6-trichloropyridinol (TCP) was performed as a model to demonstrate the application potential of this reusable miniaturized flow cell. The whole fluidic assay process including beads trapping, immuno-binding, beads washing, beads releasing and signal collection could be completed in 10 min. Immunoassay of TCP using this miniaturized device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device had been successfully used for detection of TCP spiked in rat serum with average recovery of 97%. This investigation provides a rapid, sensitive, reusable, low-cost and automatic miniaturized device for solid-phase biochemical analysis for various purposes.

60 APPLIED LIFE SCIENCES↗

Polyelectrolyte-Induced Reduction of Exfoliated Graphite Oxide: A Facile Route to Synthesis of Soluble Graphene Nanosheets

Here we report that poly(diallyldimethylammonium chloride) (PDDA) acts as both a reducing agent and a stabilizer to prepare soluble graphene nanosheets from graphite oxide. The results of transmission electron microscopy, X-ray diffraction, X-ray photoeletron spectroscopy, atomic force microscopy, and fourier transform infrared indicated that graphite oxide was successfully reduced to graphene nanosheets which exhibited single-layer structure and high dispersion in various solvents. The reaction mechanism for PDDA-induced reduction of exfoliated graphite oxide was proposed. Furthermore, PDDA facilitated the in-situ growth of highly-dispersed Pt nanoparticles on the surface of graphene nanosheets to form Pt/graphene nanocomposites, which exhibited excellent catalytic activity towards formic acid oxidation. This work presents a facile and environmentally friendly approach to the synthesis of graphene nanosheets, opens up new possibility for preparing graphene and graphene-based nanomaterials for large-scale applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilization of Electrocatalytic Metal Nanoparticles at Metal-Metal Oxide-Graphene Triple Junction Points

Carbon-supported metal catalysts are widely used in heterogeneous catalysis and electrocatalysis. In this paper, we report a novel method to deposit metal catalysts and metal oxide nanoparticles on two-dimensional graphene sheets to improve the catalytic performance and stability of the catalyst materials. The new synthesis method allows indium tin oxide (ITO) nanocrystals to be directly grown on functionalized graphene sheets forming the ITO-graphene hybrids. Pt nanoparticles are then deposited to form a special triple-junction structure (Pt-ITO-graphene). Both experimental study and periodic density functional theory calculations show that the supported Pt nanoparticles are stable at Pt-ITO-graphene triple junction points. The new catalyst materials were tested for oxygen reduction for potential applications in polymer electrolyte membrane fuel cells, and they exhibited greatly enhanced stability and activity. The reasons for the high stability and activity of Pt-ITO-graphene are analyzed.

30 DIRECT ENERGY CONVERSION↗

Design of graphene sheets-supported Pt catalyst layer in PEM fuel cells

A series of cathodes using Pt supported onto graphene sheets with different contents of carbon black in the catalyst layer were prepared and characterized. Carbon black was added as a spacer between two-dimensional graphene sheets in the catalyst layer to study its effect on the performances of proton exchange membrane fuel cell. Electrochemical properties and surface morphology of the cathodes with and without carbon black were characterized using cyclic voltammetry, ac-impedance spectroscopy, electrochemical polarization technique, and scanning electron microscopy. The results indicated that carbon black effectively modifies the array of graphene supports, resulting in more Pt nanoparticles available for electrochemical reaction and better mass transport in the catalyst layer.

30 DIRECT ENERGY CONVERSION↗

Graphene decorated with PtAu alloy nanoparticles: facile synthesis and promising application for formic acid oxidation

PtAu alloy nanoparticles (~ 3.2 nm in diameter) are synthesized in poly(diallyldimethylammonium chloride) (PDDA) aqueous solution and uniformly dispersed on graphene nanosheets. PtAu/graphene exhibits high electrocatalytic activity and stability for formic acid oxidation, which is attributed to the high dispersion of PtAu nanoparticles and the specific interaction between PtAu and graphene, indicating a promising catalyst for direct formic acid fuel cells. The facile method can be readily extended to the synthesis of other alloy nanoparticles.

30 DIRECT ENERGY CONVERSION↗

Polarization Losses under Accelerated Stress Test Using Multiwalled Carbon Nanotube Supported Pt Catalyst in PEM Fuel Cells

The electrochemical behavior for Pt catalysts supported on multiwalled carbon nanotubes and Vulcan XC-72 in proton exchange membrane fuel cells under accelerated stress test was examined by cyclic voltammetry, electrochemical impedance spectroscopy, and polarization technique. Pt catalyst supported on multiwalled carbon nanotubes exhibited highly stable electrochemical surface area, oxygen reduction kinetics, and fuel cell performance at a highly oxidizing condition, indicating multiwalled carbon nanotubes show high corrosion resistance and strong interaction with Pt nanoparticles. The Tafel slope, ohmic resistances, and limiting current density determined were used to differentiate kinetic, ohmic, mass-transfer polarization losses from the actual polarization curve. Kinetic contribution to the total overpotential was larger throughout the stress test. However, the fraction of kinetic overpotential decreased and mass-transfer overpotential portion remained quite constant during accelerated stress test, whereas the fraction of ohmic overpotential primarily originating from severe proton transport limitation in the catalyst layer increased under the anodic potential hold.

30 DIRECT ENERGY CONVERSION↗

Self-assembly of Pt nanoparticles on highly graphitized carbon nanotubes as an excellent oxygen-reduction catalyst

A novel method for the synthesis of high-performance Pt electrocatalysts on graphitized carbon nanotubes (GCNTs) is reported. GCNTs are first noncovalently functionalized with a polyelectrolyte, poly(diallyldimethylammonium chloride) (PDDA). Pt precursors are uniformly distributed on the surface of PDDA-functionalized GCNTs via the electrostatic self-assembly between negatively charged PtCl62- and positively charged functional groups of PDDA and then Pt nanoparticles are in-situ prepared with the ethylene glycol reduction method. X-ray photoelectron spectroscopy measurement confirms the successful functionalization of PDDA on GCNTs. X-ray diffraction and transmission electron microscope images reveal that Pt nanoparticles with an average size of ~ 2.7 nm are uniformly dispersed on the PDDA-functionalzied GCNTs. Pt/GCNTs electrocatalyst exhibits two times higher activity towards oxygen reduction reaction than Pt/CNTs because of the higher Pt electrochemical surface area and the higher electrical conductivity of GCNTs. Also, Pt/GCNTs exhibit a higher stability than Pt/CNTs. This enhanced durability can be attributed to the structural integrity and higher graphitization degree of GCNTs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enzyme entrapped nanoporous scaffolds formed through flow induced gelation in microfluidic filter device for sensitive biosensing of organophosphorus compounds

A novel and versatile processing method was developed for the formation of gel scaffolds with in-situ AChE-AuNPs immobilization for biosensing of organophosphorus compounds. The biosensor designed by our new approach shows high sensitivity, selectivity and reactivation efficiency. This flow induced immobilziation technique opens up new pathways for designing simple, fast, biocompatible, and cost-effective process for enhanced sensor performance and on-site testing of a variety of toxic organophosphorus compounds.

47 OTHER INSTRUMENTATION↗

Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392)

P53 phosphorylation plays an important role in many biological processes and might be used as a potential biomarker in clinical diagnoses. We report a new electrochemical immunosensor for ultrasensitive detection of phosphorylated p53 at Ser392 (phospho-p53-392) based on graphene oxide (GO) as a nanocarrier in multienzymes amplification strategy. Greatly enhanced sensitivity was achieved by using the bioconjugates featuring horseradish peroxidase (HRP) and p53392 signal antibody (p53Ab2) linked to functionalized GO (HRP-p53Ab2-GO) at high ratio of HRP/p53Ab2. After a sandwich immunoreaction, the HRP-p53Ab2-GO captured onto the electrode surface produced an amplified electrocatalytic response by the reduction of enzymatically oxidized thionine in the presence of hydrogen peroxide. The increase of response current was proportional to the phospho-p53 concentration in the range of 0.02 to 2 nM with the detection limit of 0.01 nM, which was 10-fold lower than that of traditional sandwich electrochemical measurement for p53. The amplified immunoassay developed in this work shows acceptable stability and reproducibility and the assay results for phospho-p53 spiked in human plasma also show good recovery (92%~103.8%). This simple and low-cost immunosensor shows great promise for detection of other phosphorylated proteins and clinical applications.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Performance of Graphene as Effected by Electrode Porosity and Graphene Functionalization

Graphene-based electrodes have recently gained popularity due to their superior electrochemical properties. However, the exact mechanisms of electrochemical activity are not yet understood. Here, we present data from NADH oxidation and ferri/ferrocyanide redox probe experiments to demonstrate that both (i) the porosity of the graphene electrodes, as effected by the packing morphology, and (ii) the functional group and the lattice defect concentration play a significant role on their electrochemical performance.

Catalysis↗

CdSe/ZnS quantum dots based electrochemical immunoassay for the detection of phosphorylated bovine serum albumin

A CdSe/ZnS quantum dot (QD) based electrochemical immunoassay of phosphorylated bovine serum albumin as a protein biomarker is presented. The QDs were used as labels and were conjugated with the secondary anti-phosphoserine antibody in a heterogeneous sandwich immunoassay. First, the primary BSA antibody was immobilized on polystyrene microwells, followed by the addition of BSA-OP. After that, the QD-labeled anti-phosphoserine antibody was added into microwells for immunorecognition. Finally, the bound QD was dissolved in an acid-dissolution step and was detected by electrochemical stripping analysis. The measured current responses were proportional to the concentration of BSA-OP. Under optimal conditions, the voltammetric response was linear over the range of 0.5 - 500 ng mL-1 of BSA-OP, with a detection limit of 0.5 ng mL-1 at a deposition potential of -1.2 V for 120 s. It also shows good reproducibility with a relative standard deviation of 8.6% of six times determination of 25 ng mL-1 of BSA-OP. This QD-based electrochemical immunoassay offers great promise for simple and cost-effective analysis of protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Electrochemistry and Electrocatalysis of Myoglobin Immobilized on Graphene-CTAB-Ionic Liquid Nanocomposite Film

We have investigated direct electrochemistry and electrocatalysis of myoglobin immobilized on graphene-cetylramethylammonium bromide (CTAB)-ionic liquid nanocomposite film on a glassy carbon electrode. The nanocomposite was characterized by TEM, SEM, XPS, and electrochemistry. It was found that the high surface area of graphene was helpful for immobilizing more proteins and the nanocomposite film can provide a favorable microenvironment for MB to retain its native structure and activity and to achieve reversible direct electron transfer reaction at an electrode. The nanocomposite films also exhibit good stability and catalytic activities for the electrocatalytic reduction of H2O2.

59 BASIC BIOLOGICAL SCIENCES↗

Nanomaterial-Based Electrochemical Biosensors and Bioassays

This book chapter summarizes the recent advance in nanomaterials for electrochemical biosensors and bioassays. Biofunctionalization of nanomaterials for biosensors fabrication and their biomedical applications are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Hairpin DNA Switch for Ultrasensitive Spectrophotometric Detection of DNA Hybridization Based on Gold Nanoparticles and Enzyme Signal Amplification

A novel DNA detection platform based on a hairpin-DNA switch, nanoparticles, and enzyme signal amplification for ultrasensitive detection of DNA hybridization has been developed in this work. In this DNA assay, a “stem-loop” DNA probe dually labeled with a thiol at its 5’ end and a biotin at its 3’ end, respectively, was used. This probe was immobilized on the gold nanoparticles (AuNPs) anchored by a protein, globulin, on a 96-well microplate. In the absence of target DNA, the immobilized probe with the stem-loop structure shields the biotin from being approached by a bulky horseradish peroxidase linked-avidin (avidin-HRP) conjugate due to the steric hindrance. However, in the presence of target DNA, the hybridization between the hairpin DNA probe and the target DNA causes significant conformational change of the probe, which forces biotin away from the surface of AuNPs. As a result, the biotin becomes accessible by the avidin-HRP, and the target hybridization event can be sensitively detected via the HRP catalyzed substrate 3, 3', 5, 5'-tetramethylbenzidine using spectrophometric method. Some experimental parameters governing the performance of the assay have been optimized. At optimal conditions, this DNA assay can detect DNA at the concentration of femtomolar level by means of a signal amplification strategy based on the combination of enzymes and nanoparticles. This approach also has shown excellent specificity to distinguish single-base mismatches of DNA targets because of the intrinsic high selectivity of the hairpin DNA probe.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Fabrication of a PDMS Microchip Based Immunoassay

In this paper, we describe the design and fabrication process of a polydimethylsiloxane (PDMS) microchip for on-chip multiplex immunoassay application. The microchip consists of a PDMS microfluidic channel layer and a micro pneumatic valve control layer. By selectively pressurizing the pneumatic microvalves, immuno reagents were controlled to flow and react in certain fluidic channel sites. Cross contamination was prevented by tightly closed valves. Our design was proposed to utilize PDMS micro channel surface as the solid phase immunoassay substrate and simultaneously detect four targets antigens on chip. Experiment result shows that 20psi valve pressure is sufficient to tightly close a 200µm wide micro channel with flow rate up to 20µl/min.

60 APPLIED LIFE SCIENCES↗