Search NASA⌕ Search

Engineering topics

Lin, Yuehe

Publications and source records attributed to Lin, Yuehe.

At least 163 records · Page 9

Aptamer/Graphene Oxide Nanocomplex for In Situ Molecular Probing in Living Cells

In this communication, we report the illustration of cellular delivering and in situ molecular probing in living cells by using graphene oxide nanosheets (GO-nS) as DNA cargo and sensing platform. Due to the particular interaction between GO and DNA molecules, aptamer/GO-nS nanocomplex was designed and employed to demonstrate the dramatic DNA delivering, enzymatic cleavage protecting and biosensing capabilities of GO-nS in living cells. The results show that GO-nS could successfully transfer DNA aptamer into living cells, efficiently protect oligonucleotides from enzymatic cleavage during the delivery as well as selectively monitoring intra-cellular target in situ. The as-shown advantages of graphene oxide will enable it to be an robust candidate for many biological fields, such as DNA and protein analyzing, gene and drug delivering, intracellular tracking, and in vivo monitoring, etc..

59 BASIC BIOLOGICAL SCIENCES↗

Nitrogen-doped Graphene and Its Electrochemical Applications

Nitrogen-doped graphene (N-graphene) is obtained by exposing graphene to nitrogen plasma. N-graphene exhibits much higher electrocatalytic activity toward oxygen reduction and H2O2 reduction than graphene, and much higher durability and selectivity than the widely-used expensive Pt. The excellent electrochemical performance of N-graphene is attributed to nitrogen functional groups and the specific properties of graphene. This indicates that N-graphene is promising for applications in electrochemical energy devices (fuel cells, metal-air batteries) and biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraint of DNA on Functionalized Graphene Improves Its Biostability and Specificity

The single-stranded DNA constrained on graphene surface is effectively protected from enzymatic cleavage by DNase I. The anisotropy, fluorescence, NMR, and CD studies suggest that the single-stranded DNA is promptly adsorbed onto graphene forming strong molecular interactions. Furthermore, the constraint of DNA probe on graphene improves the specificity of its response to complementary DNA. These findings will promote the further application of graphene in biotechnology and biomedical fields.

59 BASIC BIOLOGICAL SCIENCES↗

Highly durable graphene nanoplatelets supported Pt nanocatalysts for oxygen reduction

We report graphene nanoplatelets (GNP), which exhibit the advantages of both single-layer graphene and highly graphitic carbon, as a durable alternative support material for Pt nanoparticles for oxygen reduction in fuel cells. Pt nanoparticles are deposited on poly(diallyldimethylammonium chloride)(PDDA)-coated GNP, and characterized with transmission electron microscopy, X-ray diffraction, Raman spectra, and electrochemical tests. Pt/GNP exhibits greatly enhanced electrochemical durability (2-3 times that of Pt/CNT and commercial Etek Pt/C). These are attributed to the intrinsic high graphitization degree of GNP and the enhanced Pt-carbon interaction in Pt/GNP. If considering that GNP can be easily mass produced from graphite, GNP is a promising, low-cost, and durable electrocatalyst support for oxygen reduction in fuel cells.

carbon nanotubes↗

A graphene-based electrochemical sensor for sensitive detection of paracetamol

An electrochemical sensor based on the electrocatalytic activity of functionalized graphene for sensitive detection of paracetamol is presented. The electrochemical behaviors of paracetamol on graphene-modified glassy carbon electrodes (GCEs) were investigated by cyclic voltammetry and square-wave voltammetry. The results showed that the graphene-modified electrode exhibited excellent electrocatalytic activity to paracetamol. A quasi-reversible redox process of paracetamol at the modified electrode was obtained, and the over-potential of paracetamol decreased significantly compared with that at the bare GCE. Such electrocatalytic behavior of graphene is attributed to its unique physical and chemical properties, e.g., subtle electronic characteristics, attractive π–π interaction, and strong adsorptive capability. The sensor shows great promise for simple, sensitive, and quantitative detection of paracetamol.

47 OTHER INSTRUMENTATION↗

Sensitive Immunoassays of Nitrated Fibrinogen in Human Biofluids

Three new sandwich immunoassays for detection of nitrated biomarker have been established with potential applications in biomedical studies and clinical practice. In this study, nitrated human fibrinogen, a potential oxidative stress biomarker for several pathologies, was chosen as the target. To improve the sensitivity and overcome the interference caused by the complexity of human biofluids, we developed three sandwich strategies using various combinations of primary antibody and secondary antibody. All three strategies demonstrated high sensitivity and selectivity towards nitrated forms of fibrinogen in buffer, but their performances were dramatically reduced when tested with human plasma and serum samples. Systematically optimizations were carried out to investigate the effects of numerous factors, including sampling, coating, blocking, and immunoreactions. Our final optimization results indicate that two of these strategies retain sufficient sensitivity and selectivity for use as assays in human physiological samples. Specifically, detection limits reached the pM level and the linear response ranges were up to nM level with a correlation coefficient > 0.99. To our best knowledge, this is the first example of using an electrochemical immunoassay for a nitrated biomarker in a physiological fluid. This novel approach provides a rapid, sensitive, selective, cost efficient and robust bioassay for detection of oxidative stress in pathology and for clinical applications. Moreover, the sandwich strategies developed in this paper can be readily used to establish effective methods targeting other nitration biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Nitrogen-Doped Graphene and its Application in Electrochemical Biosensing

Chemical doping with foreign atoms is an effective method to intrinsically modify the properties of host materials. Among them, nitrogen (N) doping plays a critical role in regulating the electronic properties of carbon materials. Recently, graphene as a true 2-dimensional carbon material has shown fascinating applications in bioelectronics and biosensors. In this paper, we report a facile strategy to prepare N-doped graphene by using plasma treatment of pristine graphene synthesized via chemical method. Meanwhile, a possible schematic diagram has been proposed to detail the structure of N-doped graphene. By controlling the exposure time, N percentage in host grapheme can be regulated ranging from 0.11% to 1.35%. Moreover, the as prepared N-doped graphene has displayed high electrocatalytic activity to hydrogen peroxide and further been used for glucose biosensing with concentration as low as 0.01 mM in the presence of interferences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graphene Based Electrochemical Sensors and Biosensors: A Review

Graphene, emerging as a true 2-dimensional material, has received increasing attention due to its unique physicochemical properties (high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass production). This article selectively reviews recent advances in graphene-based electrochemical sensors and biosensors. In particular, graphene for direct electrochemistry of enzyme, its electrocatalytic activity toward small biomolecules (hydrogen peroxide, NADH, dopamine, etc.), and graphene-based enzyme biosensors have been summarized in more detail; Graphene-based DNA sensing and environmental analysis have been discussed. Future perspectives in this rapidly developing field are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation of homogeneous gold-silver alloy nanoparticles using the apoferritin cavity as a nanoreactor

Homogeneous Au-Ag alloy nanoparticles have been synthesized in the cavity of horse spleen apoferritin (HSAF) by a diffusion technique. Low concentration of NH4OH solution has been used stabilize Ag(I) ions at pH 8.3, where channels between the subunits of HASF are open for the diffusion of metal ions. The Au-Ag nanoparticle cores are 5.6-6.3 nm in diameter with narrow size distribution (≤ 1.0 nm), and their average diameter was gradually increased with an increase of Ag content. The core formation ratios of Au-Ag-HASF samples are higher than 80%. These series of nanoparticles were applied for the reduction of 4-nitrophenol in the presence of NaBH4. As the Au content was increased in the Au-Ag-HSAF nanoparticles, the rate constant of the reduction was exponentially increased from 1.3 x 10-3 s-1 (pure Ag-HSAF) to 7.58 x 10-2 s-1 (pure Au-HSAF). These synthesized Au-Ag nanoparticles with different compositions will be further applicable in catalysis, sensing, and biomedical areas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitive Immunosensor for Cancer Biomarker Based on Dual Signal Amplification Strategy of Graphene Sheets and Multi-Enzyme Functionalized Carbon Nanospheres

A novel electrochemical immunosensor for sensitive detection of cancer biomarker α fetoprotein (AFP) is described that uses a graphene sheet sensor platform and functionalized carbon nanospheres (CNSs) labeling with horseradish peroxidase-secondary antibodies (HRP-Ab2). Greatly enhanced sensitivity for the cancer biomarker is based on a dual signal amplification strategy: first, the synthesized CNSs yielded a homogeneous and narrow size distribution, which allowed several binding events of HRP-Ab2 on each nanosphere. Enhanced sensitivity was achieved by introducing the multi-bioconjugates of HRP-Ab2-CNSs onto the electrode surface through sandwich immunoreactions. Secondly, functionalized graphene sheets used for the biosensor platform increased the surface area to capture a large amount of primary antibodies (Ab1), thus amplifying the detection response. This amplification strategy is a promising platform for clinical screening of cancer biomarkers and point-of-care diagnostics.

60 APPLIED LIFE SCIENCES↗

Electrochemical assay of active prostate-specific antigen (PSA) using ferrocene-functionalized peptide probes

This paper presents a novel approach to electrochemically determine enzymatically active PSA using ferrocene-functionalized helix peptide (CHSSLKQK). The principle of electrochemical measurement is based on the specific proteolytic cleavage events of the FC-peptide on the gold electrode surface in the presence of PSA, resulting the change of the current signal of the electrode. The percentage of the decreased current is linear with the concentration of active PSA at the range of 0.5-40 ng/mL with a detection limit of 0.2 ng/mL. The direct transduction of peptide cleavage events into an electrical signal provides a simple, sensitive method for detecting the enzymatic activity of PSA and determining the active PSA concentration.

60 APPLIED LIFE SCIENCES↗

Nitrogen-doped mesoporous carbon for energy storage in vanadium redox flow batteries

We demonstrate a novel electrode material-nitrogen-doped mesoporous carbon (NMC)-for vanadium redox flow batteries. Mesoporous carbon (MC) is prepared using a soft-template method and doped with nitrogen by heat-treating MC in NH 3 . NMC is characterized with X-ray photoelectron spectroscopy and transmission electron microscopy. The redox reaction of [VO] 2+ /[VO 2 ] + is characterized with cyclic voltammetry and electrochemical impedance spectroscopy. The electrocatalytic kinetics of the redox couple [VO] 2+ /[VO 2 ] + is significantly enhanced on NMC electrode compared with MC and graphite electrodes. The reversibility of the redox couple [VO] 2+ /[VO 2 ] + is greatly improved on NMC (0.61 for NMC vs. 0.34 for graphite). Nitrogen doping facilitates the electron transfer on the electrode/electrolyte interface for both oxidation and reduction processes. NMC is a promising electrode material for redox flow batteries.

25 ENERGY STORAGE↗

Graphene/TiO2 Nanocomposites: Synthesis, Characterization and Application in Hydrogen Evolution from Water Photocatalytic Splitting

A series of titanium dioxide and graphene sheets (GSs) composites were synthesized with a sol-gel method using tetrabutyl titanate and graphite oxide (GO) as the starting materials. The obtained TiO2/GSs photocatalysts are characterized by X-ray diffraction, N2 adsorption analysis, Raman spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and ultraviolet-visible (UV-vis) diffuse reflectance spectroscopy. The photocatalytic activity of the as-prepared samples was evaluated by hydrogen evolution from water photocatalytic splitting under UV-vis illumination. The influence of GSs content and calcination atmosphere on the photocatalytic activity was also investigated. The results show that both GSs content and the calcinations atmosphere can affect the photocatalytic activity of the obtained composites.

08 HYDROGEN↗

Carbon nanotubes decorated with Pt nanoparticles via electrostatic self-assembly: a highly active oxygen reduction electrocatalyst

Carbon nanotubes (CNTs) are noncovalently functionalized with poly(allylamine hydrochloride) (PAH) and then employed as the support of Pt nanoparticles. X-Ray photoelectron spectroscopy confirms the successful functionalization of CNTs with PAH. The negatively charged Pt precursors are adsorbed on positively charged PAH-wrapping CNTs surface via electrostatic self-assembly and then in situ reduced in ethylene glycol. X-Ray diffraction and transmission electron microscope images reveal that Pt nanoparticles with an average size of 2.6 nm are uniformly dispersed on CNT surface. Pt/PAH-CNTs exhibit unexpectedly high activity towards oxygen reduction reaction, which can be attributed to the large electrochemical surface area of Pt nanoparticles. It also shows enhanced electrochemical stability due to the structural integrity of PAH-CNTs. This provides a facile approach to synthesize CNTs-based nanoelectrocatalysts.

36 MATERIALS SCIENCE↗

Covalent Coupling of Organophosphorus Hydrolase Loaded Quantum Dots to Carbon Nanotube/Au Nanocomposite for Enhanced Detection of Methyl Parathion

An amperometric biosensor for highly selective and sensitive determination of methyl parathion (MP) was developed based on dual signal amplification: (1) a large amount of introduced enzyme on the electrode surface and (2) synergistic effects of nanoparticles towards enzymatic catalysis. The fabrication process includes (1) electrochemical deposition of gold nanoparticles by a multi-potential step technique at multiwalled carbon nanotube (MWCNT) film pre-cast on a glassy carbon electrode and (2) immobilization of methyl parathion degrading enzyme (MPDE) onto a modified electrode through CdTe quantum dots (CdTe QDs) covalent attachment. The introduced MWCNT and gold nanoparticles significantly increased the surface area and exhibited synergistic effects towards enzymatic catalysis. CdTe QDs are further used as carriers to load a large amount of enzyme. As a result of these two important enhancement factors, the proposed biosensor exhibited extremely sensitive, perfectly selective, and rapid response to methyl parathion in the absence of a mediator.

59 BASIC BIOLOGICAL SCIENCES↗

Facile synthesis of PtAu alloy nanoparticles with high activity for formic acid oxidation

We report the facile synthesis of carbon supported PtAu alloy nanoparticles with high electrocatalytic activity as the anode catalyst for direct formic acid fuel cells (DFAFCs). PtAu alloy nanopaticles are synthesized by co-reducing HAuCl4 and H2PtCl6 with NaBH4 in the presence of sodium citrate and then the nanoparticles are deposited on Vulcan XC-72R carbon support (PtAu/C). The obtained catalysts are characterized with X-ray diffraction (XRD) and transmission electron microscope (TEM), which reveal PtAu alloy formation with an average diameter of 4.6 nm. PtAu/C exhibits 8 times higher catalytic activity toward formic acid oxidation than Pt/C. The enhanced activity of PtAu/C catalyst is attributed to noncontinuous Pt sites formed in the presence of the neighbored Au sites, which promotes direct oxidation of formic acid by avoiding poison CO.

direct formic acid fuel cell↗

Low-cost and durable catalyst support for fuel cells: graphite submicronparticles

Low-cost graphite submicronparticles (GSP) are employed as a possible catalyst support for polymer electrolyte membrane (PEM) fuel cells. Platinum nanoparticles are deposited on Vulcan XC-72 carbon black (XC-72), carbon nanotubes (CNT), and GSP via ethylene glycol (EG) reduction method. The morphologies and the crystallinity of Pt/XC-72, Pt/CNT, and Pt/GSP are characterized with X-ray diffraction and transmission electron microscope, which shows that Pt nanoparticles (~ 3.5 nm) are uniformly dispersed on GSP support. Pt/GSP exhibits the highest activity towards oxygen reduction reactions. The durability study indicates that Pt/GSP is 2 ~ 3 times durable than Pt/CNT and Pt/XC-72. The enhanced durability of Pt/GSP catalyst is attributed to the higher corrosion resistance of graphite submicronparticles, which results from higher graphitization degree of GSP support. Considering its low production cost, graphite submicronparticles are promising electrocatalyst support for fuel cells.

carbon nanotubes↗