Search NASA⌕ Search

Engineering topics

Lindgren, Eric R.

Publications and source records attributed to Lindgren, Eric R..

At least 55 records · Page 3

Test Plan for the Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission(NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the investigation described in this test plan is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator(HDCS) has been designed to generate this benchmark data and add to the existing knowledgebase. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure(MAWP)rating of 2,400 kPa at400 °C. An existing electrically heated but otherwise prototypic boiling water reactor(BWR), Incoloy-clad test assembly will be deployed inside of a representative storage basket and canister. An insulated sheet metal enclosure will be used to mimic the thermal properties of the concrete vault enclosure used in a modern horizontal storage system. Radial and axial temperature profiles along with induced cooling air flow will be measured for a wide range of decay powers and representative(and higher)cask pressures using various backfills of helium, argon, or air. The single assembly geometry with well-controlled boundary conditions simplifies computational requirements while preserving relevant physics. The proposed test apparatus integrates all the underlying thermal-hydraulics important to defining the performance of a modern horizontal storage system. These include combined-mode heat transfer from the electrically-heated assembly to the canister walls and the primarily natural-convective heat transfer from the canister to the cooling air flow passing through the horizontal vault enclosure. The objective of the HDCS is not to reproduce the performance of a commercial dry storage system for any given set of operational parameters. Rather ,the objective is to capture the dominant physics in a well-characterized test apparatus. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance. While incorporating the best available information based on thermal-hydraulic scaling arguments as well as previous vertical testing, this test plan is subject to changes due to improved understanding or from as built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of Particulate Retention in Microchannel Flows

The purpose of this study was to explore the flow rates and aerosol retention of an engineered microchannel with characteristic dimensions similar to those of stress corrosion cracks (SCCs) that could form in dry cask storage systems (DCSS) for spent nuclear fuel. Additionally, pressure differentials covering the upper limit of commercially available DCSS were studied. Given the scope and resources available, these data sets should be considered preliminary and are intended to demonstrate a new capability to characterize SCC under well-controlled boundary conditions. The gap of the microchannel tested was 28.9 gm (0.00110 in.), the width was 12.7 mm (0.500 in.), and the length was 8.86 mm (0.349 in.). Over a nine-hour period, the average mass concentration upstream of the microchannel was 0.048 mg/m 3 while the average concentration downstream was 0.030 mg/m 3 . By the end of the test, the mass of aerosols that entered the test section upstream of the microchannel was 0.207 mg and the mass of aerosols that exited the microchannel was 0.117 mg. Therefore, 44% of the aerosols available for transmission was retained upstream of microchannel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Materials and Dimensional Reference Handbook for the Boiling Water Reactor Dry Cask Simulator.

The performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed analytical modeling of the system’s thermal performance. A recent investigation has been completed that produced a data set that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations [Durbin and Lindgren, 2017]. The experiments were conducted in Albuquerque, New Mexico where the local ambient atmospheric pressure is typically 83 kPa. The purpose of this handbook is to document the pertinent geometric and material property information needed to perform model validation efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗