Search NASA⌕ Search

Engineering topics

Liu, C.

Publications and source records attributed to Liu, C..

At least 55 records · Page 3

Verification and validation of linear gyrokinetic and kinetic-MHD simulations for internal kink instability in DIII-D tokamak

Here, verification and linear validation of the internal kink instability in tokamak have been performed for both gyrokinetic (GTC) and kinetic-MHD codes (GAM-solver, M3D-C1-K, NOVA, XTOR-K). Using realistic magnetic geometry and plasma profiles from the same equilibrium reconstruction of the DIII-D shot #141216, these codes exhibit excellent agreement for the growth rate and mode structure of the internal kink mode when all kinetic effects are suppressed. The simulated radial mode structures, obtained from linear simulations, are in reasonable agreement with the normalised electron cyclotron emission measurement after adjusting, within the experimental uncertainty, the safety factor q = 1 flux-surface location in the equilibrium reconstruction. Compressible magnetic perturbations strongly destabilize the kink, while poloidal variations of the equilibrium current density reduce the growth rate of the kink. Furthermore, kinetic effects of thermal ions are found to decrease the kink growth rate in kinetic-MHD simulations, but increase the kink growth rate in gyrokinetic simulations, due to the additional drive of the ion temperature gradient and parallel electric field. Kinetic thermal electrons are found to have negligible effects on the internal kink instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Status Update of the Electron-Ion Collider

The design of the electron-ion collider EIC to be constructed at Brookhaven National Laboratory has been continuously evolving towards a realistic and robust design that meets all the requirements set forth by the nuclear physics community in the White Paper. Over the past year activities have been focused on maturing the design, and on developing alternatives to mitigate risk. These include improvements of the interaction region design as well as modifications of the hadron ring vacuum system to accommodate the high average and peak beam currents. Beam dynamics studies have been performed to determine and optimize the dynamic aperture in the two collider rings and the beam-beam performance. We will present the EIC design with a focus on recent developments.

43 PARTICLE ACCELERATORS↗

Effects of organized convection parameterization on the MJO and precipitation in E3SMv1. Part I: Mesoscale heating

Mesoscale organization of convection is typically not represented in global circulation models, and hence its influence on the global circulation is not accounted for. The heating component of a parameterization that represents the dynamical and physical effects of circulations associated with organized convection, referred to as the multiscale coherent structure parameterization (MCSP), is implemented in the Energy Exascale Earth System Model version 1 (E3SMv1). Numerical simulations are conducted to assess its impact on the simulated climate. Besides E3SMv1 simulations, we performed high-resolution (1 km) simulations using the Weather Research and Forecasting (WRF) Model to determine the temperature tendencies induced by mesoscale convective systems embedded in deep convection. We tuned the free parameters of the MCSP based on the WRF simulations. MCSP heating enhances Kevin wave spectra in E3SMv1, improves the representation of the Madden-Julian Oscillation, and impacts on mean precipitation that vary with locations and seasons, including a reduction of biases over the tropical Pacific.

Climate Modeling↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron lenses in RHIC: status and prospects

Two electron lenses are installed in Relativistic Heavy Ion Collider (RHIC). They were used as operational head-on beam-beam compensators in proton-proton collisions, with Gaussian transverse electron beam profiles. One of the lenses was also used with a hollow transverse profile to test hadron beam halo removal under various conditions. Although presently not in the design, the lenses may find applications in the Electron-ion Collider (EIC) for either collimation or beam-beam mitigation.

43 PARTICLE ACCELERATORS↗