Search NASA⌕ Search

Engineering topics

Liu, Sheng

Publications and source records attributed to Liu, Sheng.

At least 37 records · Page 2

All-optical tuning of symmetry protected quasi bound states in the continuum

We demonstrate all-optical switching of high quality factor quasibound states in the continuum resonances in broken symmetry GaAs metasurfaces. By slightly breaking the symmetry of the GaAs nanoresonators, we enable leakage of symmetry protected bound states in the continuum (BICs) to free space that results in sharp spectral resonances with high quality factors of ~500. We tune the resulting quasi-BIC resonances with ultrafast optical pumping at 800 nm and observe a 10 nm spectral blue shift of the resonance with pump fluences of less than 100 μJ cm -2 . The spectral shift is achieved in an ultrafast time scale (<2.5 ps) and is caused by a shift in the refractive index mediated by the injection of free carriers into the GaAs resonators. An absolute reflectance change of 0.31 is measured with 150 μJ cm -2 . Our results demonstrate a proof-of-concept that these broken symmetry metasurfaces can be modulated or switched at ultrafast switching speeds with higher contrast at low optical fluences (<100 μJ cm-2) than conventional Mie-metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Evidence of the Lorentz-like Effective Medium Resonance in Semiconductor Hyperbolic Metamaterials using Strong Coupling to Plasmonic Metasurfaces

The Lorentz-like effective medium resonance (LEMR) exhibited by the longitudinal effective permittivity of semiconductor hyperbolic metamaterials (SHMs) has been known for some time. However, direct observation of this resonance proved to be difficult. Here we experimentally demonstrate its existence by strongly coupling SHMs to plasmonic metasurfaces. We consider four strong coupling implementations of SHMs that exhibit different LEMR absorption profiles (both in frequency and strength) to validate our approach.

42 ENGINEERING↗

Active optical device enabled by dielectric metamaterials

An array of dielectric resonators is formed on a substrate. Each resonator includes an active medium having an optical transition that is operative in a process of photodetection or photoemission. The active media each include a quantum well multilayer. The dielectric resonators in the array are each dimensioned to provide a resonance that lies substantially at the frequency of the optical transition.

36 MATERIALS SCIENCE↗

Realization of Wideband Magnetoelectric Response Utilizing Three-Phase Particulate Ceramics

This paper is aimed at acquiring functional ceramics with broadband magnetoelectric (ME) response for sensing wide-range of dc bias magnetic field. Three-phase particulate ceramics CoFe{sub 2}O{sub 4}/Ni{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4}/Bi{sub 0.5}Na{sub 0.4}K{sub 0.1}TiO{sub 3} (CFO/NZFO/BNKT) were fabricated, and the effect of magnetostrictive phase on the piezoelectric, magnetic, and ME properties were investigated systematically. Separated phases and homogeneous microstructure of the magnetostrictive and piezoelectric phases were confirmed. The variation in magnetostrictive coefficient with dc magnetic field was found to be markedly dependent on the relative content of magnetostrictive microparticles. By merging the nonlinear piezomagnetic response of the two ferrite components together, the ME composites present dual-peak bands. A wide-range ME coefficient was achieved over a magnetic range of 1800 Oe with large ME value of 20 mV/cm Oe. This field-conversion broadband ME behavior indicates that three-phase particulate ME ceramics are quite preferable for practical applications in magnetic field sensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Manipulating efficient light emission in two-dimensional perovskite crystals by pressure-induced anisotropic deformation

The hybrid nature and soft lattice of organolead halide perovskites render their structural changes and optical properties susceptible to external driving forces such as temperature and pressure, remarkably different from conventional semiconductors. Here, we investigate the pressure-induced optical response of a typical two-dimensional perovskite crystal, phenylethylamine lead iodide. At a moderate pressure within 3.5 GPa, its photoluminescence red-shifts continuously, exhibiting an ultrabroad energy tunability range up to 320 meV in the visible spectrum, with quantum yield remaining nearly constant. First-principles calculations suggest that an out-of-plane quasi-uniaxial compression occurs under a hydrostatic pressure, while the energy is absorbed by the reversible and elastic tilting of the benzene rings within the long-chain ligands. This anisotropic structural deformation effectively modulates the quantum confinement effect by 250 meV via barrier height lowering. The broad tunability within a relatively low pressure range will expand optoelectronic applications to a new paradigm with pressure as a tuning knob.

36 MATERIALS SCIENCE↗

Predictors of Recurrent Biliary Obstruction Following Percutaneous Uncovered Metal Stent Insertion in Patients with Distal Malignant Biliary Obstruction: An Analysis Using a Competing Risk Model

Objective: To evaluate predictive factors of recurrent biliary obstruction (RBO) following percutaneous uncovered metal stent placement for unresectable distal malignant biliary obstruction (MBO) by using a competing risk model. Materials and Methods: Between March 2012 and March 2016, 119 patients underwent percutaneous uncovered metal stent placement with distal MBO at our institution. Univariate and multivariate analyses were conducted to identify the prognostic factors for RBO using a competing risk model. Results: The median overall survival period was 170 days (range 19–775 days). Recurrent biliary obstruction before death was observed in 34 patients (28.6%). The 3-, 6-, and 12-month cumulative incidences of RBO were 14.3%, 21.0%, and 27.7%, respectively. A multivariate analysis indicated that ampullary carcinoma compared with metastatic carcinoma (hazard ratio [HR] = 4.86; 95% confidence interval [CI], 1.74–13.54; P = 0.003) and a stent insertion above the sphincter of Oddi (HR 2.49; 95% CI, 1.11–5.62; P = 0.028) were the independent risk factors for RBO when we considered death to be a competing risk. Conclusion: Ampullary carcinoma and stent insertion above the sphincter of Oddi were risk factors for RBO in these patients who received percutaneous transhepatic stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Percutaneous Stent Placement with Iodine-125 Seed Strand for Malignant Biliary Obstruction

Purpose: To evaluate the effectiveness and safety of simultaneous placement of a self-expandable metallic stents (SEMS) and iodine-125 seed strand in the management of malignant obstructive jaundice (MOJ). Materials and Methods: This study included 132 patients with MOJ treated from November 2015 to October 2017. Forty-five patients underwent insertion of SEMS with iodine-125 seed strands (Seeds group); the remaining 87 patients underwent SEMS placement alone (Control group). Technical success was defined as accurate, successful deployment of SEMS with or without iodine-125 seed strand; clinical success was defined as 20% reduction in serum bilirubin within 1 week after the procedure, compared with baseline. Complications, duration of primary stent patency, and overall survival were evaluated. Results: Technical success was achieved in all patients in both groups. In the Seeds group, an average of 14 seeds (range 8–22) were implanted in the bile duct as a strand. Clinical success rates were similar between the groups (Seeds group, 93.3%; Control group, 95.4%). Major complications occurred in only one patient, in the Control group. The median period of primary stent patency was significantly longer in the Seeds group (194 days) than in the Control group (86 days; P = 0.049). The median overall survival was also significantly longer in the Seeds group (194 days) than in the Control group (96 days; P = 0.031). Conclusion: SEMS combined with iodine-125 seed strands is effective and safe in the management of MOJ and can improve stent patency and patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Safety and Efficacy of Oxycodone Versus Fentanyl in Percutaneous Microwave Ablation of a Liver Tumour Abutting the Capsule

Purpose: The present study compared the safety and efficacy of oxycodone with those of fentanyl under non-intubated general anaesthesia in percutaneous microwave ablation (MWA) of a liver tumour abutting the capsule. Materials and Methods: Thirty-eight patients underwent MWA of liver cancers abutting the capsule. Patients received 0.1 mg/kg oxycodone (O group) or 1 μg/kg fentanyl (F group) prior to the start of ablation. Both groups received continuous infusions of propofol for non-intubated general anaesthesia during ablation. The primary outcomes were the pain scores (11-point numeric rating scale, NRS) within 24 h after MWA. Vital signs, body movement during ablation, and opioid side effects after ablation were recorded. The need for additional analgesics was recorded 24 h after MWA. Results: The pain NRS scores were lower in the O group than in the F group at 0.5 (P = 0.035), 3 (P = 0.002), and 6 h (P = 0.001) after MWA, and fewer patients required additional analgesics in the O group (6 of 20 vs. 13 of 18, P = 0.022) within 24 h. The average 24-h dose of dezocine was 5.5 ± 4.1 mg in the F group and 2.1 ± 3.3 mg in the O group (P = 0.008). A significant reduction in the respiratory rate (P = 0.020) and more body movements were observed in the F group (P = 0.027) during ablation with non-intubated general anaesthesia. No differences in post-operative nausea and vomiting (PONV) were observed between the two groups, but dizziness occurred significantly more often in the O group (P = 0.033). No significant differences in other vital signs were observed before, during, and after the procedure. Conclusions: Oxycodone provides better analgesia and reduces post-operative opioid consumption without significant respiratory or hemodynamic instability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optoelectronic apparatus enabled by dielectric metamaterials

An array of dielectric resonators is formed on the substrate of an optoelectronic device. Each resonator includes an active medium having an optical transition that is operative in a process of photodetection or photoemission. The dielectric resonators in the array are each dimensioned to provide a resonance that lies substantially at the frequency of the optical transition.

36 MATERIALS SCIENCE↗

Light-Emitting Metasurfaces: Simultaneous Control of Spontaneous Emission and Far-Field Radiation

Light-emitting sources and devices permeate every aspect of our lives and are used in lighting, communications, transportation, computing, and medicine. Advances in multifunctional and “smart lighting” would require revolutionary concepts in the control of emission spectra and directionality. Such control might be possible with new schemes and regimes of light–matter interaction paired with developments in light-emitting materials. We show that all-dielectric metasurfaces made from III–V semiconductors with embedded emitters have the potential to provide revolutionary lighting concepts and devices, with new functionality that goes far beyond what is available in existing technologies. Specifically, we use Mie-resonant metasurfaces made from semiconductor heterostructures containing epitaxial quantum dots. By controlling the symmetry of the resonant modes, their overlap with the emission spectra, and other structural parameters, we can enhance the brightness by 2 orders of magnitude, as well as reduce its far-field divergence significantly.

77 NANOSCIENCE AND NANOTECHNOLOGY↗