Search NASA⌕ Search

Engineering topics

Louie, Melissa Sui-hui

Publications and source records attributed to Louie, Melissa Sui-hui.

Compressor Station Differential Risk Assessment for Hydrogen and Natural Gas Blends

Blending hydrogen into existing natural gas pipelines is a current initiative for large-scale hydrogen deployment in the United States. Understanding changes in hazards and risk for fuel blends can help inform regulations. A differential risk assessment was conducted to understand how the safety profile of fires and unignited flammable plumes of leaking fuel would change based on blend composition. The area affected by harmful heat fluxes from jet fires was found to be larger for blends with more natural gas in them, while the distance affected by unignited flammable fuel concentrations was found to be larger for blends with more hydrogen in them. Component leak frequencies and ignition probabilities greatly impact both heat flux risk and the flammable plume risk. The collection of additional blend-specific industry data could help understand which assumptions are most valid to make when calculating risk.

08 HYDROGEN↗

Reduced-Order Modeling of Hydrogen Releases from Vent Stacks and with Wind

This report describes computational modeling in the HyRAM+ software for study of hydrogen behavior in two common scenarios. First, models of unignited plumes exiting a vent stack were considered. It was shown that entrainment and vent backpressure were major factors in plume physics. Second, HyRAM+ was extended to include wind effects on plumes by modifying the plume momentum balance and entrainment modeling. Use of the model showed that plume shape and length changed with wind speed and direction; in all cases, wind causes a shortening of the plume along the streamline. While the no-wind case in HyRAM+ has been validated and the newly developed wind model was fitted to very limited experimental data, more controlled experimental configurations would help validate the models and ensure accurate simulation of hydrogen plume behavior for vent stack releases or in wind.

08 HYDROGEN↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems are becoming more widely deployed throughout the country, and as their presence continues to grow, it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity, and to the company that owns the facility. The two main mechanisms malicious actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when facility managers conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks applicable to a wide variety of hydrogen storage systems by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

Safety Review of the Hydrogen Components of a Reference Design of the Wind-H2-Green Steel/Ammonia Project

The Department of Energy Hydrogen Fuel Cell Technology Office and Wind Energy Technologies Office’s Wind-H2-Green Steel/Ammonia project is an initiative to demonstrate the feasibility and efficacy of GW-scale integrated energy systems. The team designed reference facilities that utilize wind- and solar-produced hydrogen for industrial steel and ammonia production. This novel concept warranted review of safety codes and standards as they apply to the designs and the identification of codes and standards as they apply to the designs and the identification of codes and standards gaps. This report reviews hydrogen production and storage codes and standards using reference design specifications from a Minnesota steel plant. Requirements, recommendations, and exclusions for the system were identified. Observed gaps included non-specific salt cavern storage requirements, electrolyzer capacity beyond regulated ranges, and lack of requirements for iron reduction via hydrogen. This report will aide future project design efforts and may provide a basis for safety reviews in new designs for industrial facilities with hydrogen production integration.

08 HYDROGEN↗

Evaluation of Hydrogen Storage Quantity Limits for Safety Requirements

As hydrogen storage facilities increase in size and capacity, it may be necessary to evaluate codes and standards that regulate hydrogen, especially in relation to allowable aggregate quantities. Existing regulations for other substances with comparable hazards such as oxygen, natural gas, and petroleum were reviewed; most fuels do not have aggregate quantity limits despite sometimes having individual tank capacity restrictions or limits for certain non-industrial, indoor, or small-scale applications. This precedent suggests that specifying a hydrogen quantity limit may not be necessary. Several possible methods for identifying an appropriate limit are presented to illustrate different approaches for a limit basis. These methods are based on overall risk, or the specific consequences inflicted by a jet fire or an explosion on people and infrastructure. However, these example metrics tend to require assumptions about potential leak sizes, suggesting that a general aggregate quantity limit would be difficult to justify without more system-specific requirements.

08 HYDROGEN↗

Quantitative Risk Assessment for Hydrogen-Powered Locomotive Refueling

Hydrogen powered locomotives are being explored to reduce emissions in rail applications. The risks of operations like refueling should be understood to ensure safe environments for workers and members of the public. Sensitivity analyses were conducted using HyRAM+ to identify major drivers of risk and compare effects of system parameters on individual risk. The consequences of jet fires from full-bore leaks dominated the risk, compared to explosions or smaller leaks. Pipe size, leak detection capability, and leak frequencies of system components greatly affected risk while overpressure modeling parameters and ambient conditions had little effect. The effects of personal protective equipment (PPE) materials on individual risk were quantified by reducing the individual’s exposure time or absorbed thermal dose. PPE only showed a risk reduction in low-risk cases. This study highlighted target areas for risk mitigation, including leak detection equipment and component maintenance, and indicated that the minimal effects of other parameters on risk may not justify prescriptive requirements for refueling operators.

08 HYDROGEN↗

Topical Analyses Related to Co-located Industrial Facilities at Nuclear Power Plants

This report investigates topics of interest with regard to Nuclear Power Plants (NPPs) utilizing flexible plant operations and generation (FPOG). Previous reports have identified the risk associated with co-located hydrogen generation facilities. This report evaluates special topics with regard to co-location of both hydrogen and syngas production facilities. A literature review was conducted to evaluate overpressure mitigation techniques that may be available to the NPP to reduce the consequence of an overpressure event. Also, the overpressure consequence of a catastrophic hydrogen storage tank failure event was analyzed. A comparison of the similarities and differences between the methodology utilized in HyRAM+ and Regulatory Guide 1.91 (R.G. 1.91) was performed for overpressure analysis. Also, the trinitrotoluene (TNT) equivalency methodology was utilized to evaluate an overpressure event at a Syngas production facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗