Search NASA⌕ Search

Engineering topics

Lu, Xing

Publications and source records attributed to Lu, Xing.

At least 19 records

Chemical templates of the Central Molecular Zone

Context . The Central Molecular Zone (CMZ) of the Milky Way exhibits extreme conditions, including high gas densities, elevated temperatures, enhanced cosmic-ray ionization rates, and large-scale dynamics. This makes it a perfect laboratory for astrochemical studies. With large-scale molecular surveys revealing increasing chemical and physical complexity in the CMZ, it is essential to develop robust methods to decode the chemical information embedded in this extreme region. Aims . A key step to interpreting the molecular richness found in the CMZ is building chemical templates tailored to its diverse conditions. In particular, understanding how CMZ environments affect shock and protostellar chemistry is crucial. The combined impact of high ionization, elevated temperatures, and dense gas remains insufficiently explored for observable tracers. Methods . For this study, we utilized UCLCHEM , a gas-grain time-dependent chemical model, to link physical conditions with their corresponding molecular signatures and identify key tracers of temperature, density, ionization, and shock activity. To achieve this, we ran a grid of models of shocks and protostellar objects representative of typical CMZ conditions, focusing on 24 species, including complex organic molecules. Results . Shocked and protostellar environments show distinct evolutionary timescales (≲10 4 vs. ≳10 4 years); 300 K emerges as a key temperature threshold for chemical differentiation. We find that cosmic-ray ionization and temperature are the main drivers of chemical trends. HCO + , H 2 CO, and CH 3 SH trace ionization, while HCO, HCO + , CH 3 SH, CH 3 NCO, and HCOOCH 3 show consistent abundance contrasts between shocks and protostellar regions over similar temperature ranges. Conclusions . We characterized the behavior of 24 species in protostellar and shock-related environments. While our models underpredict some complex organics in shocks, they reproduce observed trends for most species, supporting scenarios involving a need for recurring shocks in Galactic Center clouds and enhanced ionization toward Sgr B2(N2). Future work should assess the role of shock recurrence and metallicity in shaping chemistry.

Galaxy: center↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Open Source Modeling Framework for Interdependent Energy-Transportation-Communication Infrastructure in Smart and Connected Communities

Infrastructure in future smart and connected communities is envisioned as an aggregate of public services, including energy, transportation, and communication systems, all intertwined with each other. The intrinsic interdependency among these systems may exert the underlying influence on both design and operation of the heterogeneous infrastructures. Yet, few prior studies have tapped into the interdependency among these systems in order to quantify their potential impacts during standard operation. In response to this, this paper proposes an open-source, flexible, integrated modeling framework suitable for designing coupled energy, transportation, and communication systems and for assessing the impact of their interdependencies. First, a novel multi-level, multi-layer, multi-agent approach is proposed to enable flexible modeling of the interconnected systems. Then, for the framework's proof of concept, preliminary component and system-level models for different systems are designed and implemented using Modelica, an equation-based object-oriented modeling language. Finally, three case studies of gradually increasing complexity are presented (energy, energy + transportation, and energy + transportation + communication) to evaluate the interdependencies among the three systems. Quantitative analyses show that the deviation of the average velocity on the road can be 10.5% and the deviation of the power drawn from the grid can be 7% with or without considering the transportation and communication system at the peak commute time, indicating the presence of notable interdependencies. The proposed modeling framework also has the potential to be further extended for various modeling purposes and use cases, such as dynamic modeling and optimization, resilience analysis, and integrated decision making in future connected communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-quality mesoporous graphene particles as high-energy and fast-charging anodes for lithium-ion batteries

The application of graphene for electrochemical energy storage has received tremendous attention; however, challenges remain in synthesis and other aspects. Here we report the synthesis of high-quality, nitrogen-doped, mesoporous graphene particles through chemical vapor deposition with magnesium-oxide particles as the catalyst and template. Such particles possess excellent structural and electrochemical stability, electronic and ionic conductivity, enabling their use as high-performance anodes with high reversible capacity, outstanding rate performance (e.g., 1,138 mA h g -1 at 0.2 C or 440 mA h g -1 at 60 C with a mass loading of 1 mg cm -2 ), and excellent cycling stability (e.g., >99% capacity retention for 500 cycles at 2 C with a mass loading of 1 mg cm -2 ). Interestingly, thick electrodes could be fabricated with high areal capacity and current density (e.g., 6.1 mA h cm -2 at 0.9 mA cm -2 ), providing an intriguing class of materials for lithium-ion batteries with high energy and power performance.

25 ENERGY STORAGE↗

Personal thermal management using portable thermoelectrics for potential building energy saving

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 degrees C (70 degrees F) and 23.9 degrees C (75 degrees F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SMA Observations of the Hot Molecular Core IRAS 18566+0408

We present Submillimeter Array (SMA) observations toward the high-mass star-forming region IRAS 18566+0408. Observations at the 1.3 mm continuum and in several molecular line transitions were performed in the compact (2.″4 angular resolution) and very-extended (∼0.″4 angular resolution) configurations. The continuum emission from the compact configuration shows a dust core of 150 M {sub ⊙}, while the very-extended configuration reveals a dense (2.6 × 10{sup 7} cm{sup −3}) and compact (∼4000 au) condensation of 8 M {sub ⊙}. We detect 31 molecular transitions from 14 species including CO isotopologues, SO, CH{sub 3}OH, OCS, and CH{sub 3}CN. Using the different k-ladders of the CH{sub 3}CN line, we derive a rotational temperature at the location of the continuum peak of 240 K. The {sup 12}CO(2−1), {sup 13}CO(2−1), and SO(6{sub 5}--5{sub 4}) lines reveal a molecular outflow at PA ∼ 135° centered at the continuum peak. The extended {sup 12}CO(2−1) emission has been recovered with the IRAM 30 m telescope observations. Using the combined data set, we derive an outflow mass of 16.8 M {sub ⊙}. The chemically rich spectrum and the high rotational temperature confirm that IRAS 18566+0408 is harboring a hot molecular core. We find no clear velocity gradient that could suggest the presence of a rotational disk-like structure, even at the high-resolution observations obtained with the very-extended configuration.

79 ASTRONOMY AND ASTROPHYSICS↗

A Massive Prestellar Clump Hosting No High-mass Cores

The infrared dark cloud (IRDC) G028.23-00.19 hosts a massive (1500 M {sub ⊙}), cold (12 K), and 3.6–70 μ m IR dark clump (MM1) that has the potential to form high-mass stars. We observed this prestellar clump candidate with the Submillimeter Array (∼3.″5 resolution) and Jansky Very Large Array (∼2.″1 resolution) in order to characterize the early stages of high-mass star formation and to constrain theoretical models. Dust emission at 1.3 mm wavelength reveals five cores with masses ≤15 M {sub ⊙}. None of the cores currently have the mass reservoir to form a high-mass star in the prestellar phase. If the MM1 clump will ultimately form high-mass stars, its embedded cores must gather a significant amount of additional mass over time. No molecular outflows are detected in the CO (2-1) and SiO (5-4) transitions, suggesting that the SMA cores are starless. By using the NH{sub 3} (1, 1) line, the velocity dispersion of the gas is determined to be transonic or mildly supersonic (Δ V {sub nt}/Δ V {sub th} ∼ 1.1–1.8). The cores are not highly supersonic as some theories of high-mass star formation predict. The embedded cores are four to seven times more massive than the clump thermal Jeans mass and the most massive core (SMA1) is nine times less massive than the clump turbulent Jeans mass. These values indicate that neither thermal pressure nor turbulent pressure dominates the fragmentation of MM1. The low virial parameters of the cores (0.1–0.5) suggest that they are not in virial equilibrium, unless strong magnetic fields of ∼1–2 mG are present. We discuss high-mass star formation scenarios in a context based on IRDC G028.23-00.19, a study case believed to represent the initial fragmentation of molecular clouds that will form high-mass stars.

79 ASTRONOMY AND ASTROPHYSICS↗