Search NASA⌕ Search

Engineering topics

Lunin, Andrei

Publications and source records attributed to Lunin, Andrei.

At least 19 records

Strategies for Superconducting Transmon Qubits with Millisecond T1 Relaxation Time

Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.

Crisa, Francesco↗

Strategies for Superconducting Transmon Qubits with Millisecond T1 Relaxation Time

Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.

Crisa, Francesco↗

Systematic improvements in transmon qubit coherence enabled by niobium surface encapsulation

Abstract We present a transmon qubit fabrication technique that yields systematic improvements in T 1 relaxation times. We encapsulate the surface of niobium and prevent the formation of its lossy surface oxide. By maintaining the same superconducting metal and only varying the surface, this comparative investigation examining different capping materials, such as tantalum, aluminum, titanium nitride, and gold, as well as substrates across different qubit foundries demonstrates the detrimental impact that niobium oxides have on coherence times of superconducting qubits, compared to native oxides of tantalum, aluminum or titanium nitride. Our surface-encapsulated niobium qubit devices exhibit T 1 relaxation times 2–5 times longer than baseline qubit devices with native niobium oxides. When capping niobium with tantalum, we obtain median qubit lifetimes above 300 μs, with maximum values up to 600 μs. Our comparative structural and chemical analysis provides insight into why amorphous niobium oxides may induce higher losses compared to other amorphous oxides.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crab Cavities for ILC

For the 14 mrad crossing angle proposed, crab cavity systems are fundamentally anticipated for the viable operation of the International Linear Collider (ILC), in order to maximise its luminosity performance. Since 2021, a specialist development team have been defining optimum crab cavity technologies which can fulfil the operational requirements for ILC, both for its baseline centre-of-mass energy of 250 GeV, but also extending those requirements out to higher beam collision intensities. Five design teams have established crab cavity technology solutions, which have the capability to also operate up to 1 TeV centre-of-mass. This presentation showcases the key performance capabilities of these designs and their associated benefits for both manufacture and integration into the ILC Interaction Region. The recommended outcome of the recently conducted crab cavity technology down-selection, will also be highlighted.

43 PARTICLE ACCELERATORS↗

LCSL-II Cryomodule Testing at Fermilab

Cold powered testing of all LCLS-II production cryomodules at Fermilab is complete as of February 2021. A total of twenty-five tests on both 1.3 GHz and 3.9 GHz cryomodules were conducted over a nearly five year time span beginning in the summer of 2016. During the course of this campaign cutting-edge results for cavity Q₀ and gradient in continuous wave operation were achieved. A summary of all test results will be presented, with a comparison to established acceptance criteria, as well as overall test stand statistics and lessons learned.

43 PARTICLE ACCELERATORS↗

Searches for New Particles, Dark Matter, and Gravitational Waves with SRF Cavities

This is a Snowmass white paper on the utility of existing and future superconducting cavities to probe fundamental physics. Superconducting radio frequency (SRF) cavity technology has seen tremendous progress in the past decades, as a tool for accelerator science. With advances spear-headed by the SQMS center at Fermilab, they are now being brought to the quantum regime becoming a tool in quantum science thanks to the high degree of coherence. The same high quality factor can be leveraged in the search for new physics, including searches for new particles, dark matter, including the QCD axion, and gravitational waves. We survey some of the physics opportunities and the required directions of R&D. Given the already demonstrated integration of SRF cavities in large accelerator systems, this R&D may enable larger scale searches by dedicated experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multibunch Studies for LCLS-II High Energy Upgrade

The Linac Coherent Light Source (LCLS) X-ray free-electron laser at SLAC is being upgraded to LCLS-II with a superconducting linac and 1 MHz bunch repetition rate. The proposed high-energy upgrade (LCLS-II-HE) will increase the beam energy from 4 to 8 GeV, extending the reach of accessible X-ray photon energies. With the increased repetition rate and longer linac of LCLS-II-HE, multi-bunch effects are of greater concern. We use recently introduced capabilities in the beam transport code ELEGANT to study dipole and monopole beam breakup effects for LCLS-II HE beam parameters. The results indicate that resonant dipole kicks have steady-state settle times on the order of 500 bunches or less and appear manageable. We also consider a statistical variation of the cavity frequencies and transverse offsets of cavities and quadrupoles. Resonant emittance growth driven by monopole kicks is found to be disrupted by frequency variation between cavities.

43 PARTICLE ACCELERATORS↗

Test Results of the Prototype SSR1 Cryomodule for PIP-II at Fermilab

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses has been successfully assembled and cold tested in the framework of PIP-II project at Fermilab. The performance of cavities and focusing lenses along with test results of other cryomodule’s key parameters are presented in this contribution.

43 PARTICLE ACCELERATORS↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

Status of PIP-II 650 MHz Prototype Dressed Cavity Qualification

Low-beta and high-beta sections of PIP-II linac will use nine low-beta cryomodules with four cavities each and four high-beta cryomodules with six cavities each. These cavities will be produced and qualified in collaboration between Fermilab and the international partner labs. Prior to their installation into prototype cryomodules, several dressed cavities, which include jacketed cavities, high power couplers, and tuners, will be qualified in STC horizontal test bed at Fermilab. After qualification of bare β = 0.9 cavities at Fermilab, several pre-production β = 0.92 and β = 0.61 cavities have been and are being fabricated and qualified. Procurements have also been started for high power couplers and tuners. In this contribution we present the current status of prototype dressed cavity qualification for PIP-II.

43 PARTICLE ACCELERATORS↗

A White Paper on Design and Fabrication of SRF Deflecting Cavities for Elletra-2

Synchrotron Trieste (ST) operates an X-ray light source Elettra and plans to upgrade it to a low-emittance high-brightness X-ray source Elettra-2.0 based on a multi-bend achromat lattice. There is also a significant interest among Elettra users to pursue time-resolved studies of matter choosing the appropriate X-ray pulse duration in the range from 20 picoseconds to a few picoseconds FWHM. Recently, X. Huang (SLAC) and A. Zholents (ANL) performed a study sponsored by ST and proposed modifications to the Elettra-2.0 design that will allow production of picosecond x-ray pulses on many beamlines. They showed that two radio frequency deflecting cavities with slightly different frequencies can be installed in the ring’s sector 8 and produce time-dependent orbit deflection to a few dedicated electron bunches without affecting other regular bunches. These special bunches produce X-ray pulses in which transverse position or angle, or both, are correlated with time. The short X-ray pulse is then obtained by using a narrow slit positioned downstream in the beamline. Many technical details of the proposed modification to Elettra-2.0 are discussed in the supplemental report. We present here the design of a multicell superconducting deflecting cavity for the purpose of the ST Short Pulse X-ray (SPX) project.

43 PARTICLE ACCELERATORS↗

Statistical Analysis of the Eigenmode Spectrum in the SRF Cavities with Mechanical Imperfections

The superconducting radio frequency (SRF) technology is progressing rapidly over last decades toward high accelerating gradients and low surface resistance making feasible the particle accelerators operation with high beam currents and long duty factors. However, the coherent RF losses due to high order modes (HOMs) excitation becomes a limiting factor for these regimes. In spite of the operating mode, which is tuned separately, the parameters of HOMs vary from one cavity to another due to finite mechanical tolerances during cavities fabrication. It is vital to know in advance the spread of HOM parameters in order to predict unexpected cryogenic losses, overheating of beam line components and to keep stable beam dynamics. In this paper we present the method of generating the unique cavity geometry with imperfections while preserving operating mode frequency and field flatness. Based on the eigenmode spectrum calculation of series of randomly generated cavities we can accumulate the data for the evaluation the HOM statistics. Finally, we describe the procedure for the estimation of the probability of the resonant HOM losses in the SRF resonators. The study of these effects leads to specifications of SC cavity and cryomodule and can significantly impact on the efficiency and reliability of the machine operation

43 PARTICLE ACCELERATORS↗

Status of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II [Slides]

Production and testing of 1.3 GHz cryomodules for the LCLS-II project is ongoing at Fermilab. Each cryomodule is assembled of eight superconducting TESLA-shape elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is a part of the cavities incoming quality control inspection and the final cryomodule qualification cold test at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure of HOM spectrum measurement and present the accumulated statistics of HOM frequencies and quality factors relevant to multiply cavity vendors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the First LCLS-II Cryomodules: Issues and Solutions

LCLS-II 4 GeV linac is on the middle production stage. Linac contains 40 cryomodules of 1.3 GHz and 3 cryomodules of 3.9 GHz, including spares. Fermilab and JLAB share responsibility for cryomodule design, assembly and test. Paper will overview the performance of the cryomodules it the tests, lessons learned and modifications in design to improve performance.

43 PARTICLE ACCELERATORS↗