Search NASA⌕ Search

Engineering topics

Lunin, Andrei

Publications and source records attributed to Lunin, Andrei.

32 records · Page 2

LCLS-II Cryomodules Production at Fermilab

LCLS-II is a planned upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac will consist of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab are currently producing in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW operation. Two prototype cryomodules had been assembled and tested. After prototype cryomodule tests, both laboratories have increased cryomodule production rate to meet the challenging LCLS-II project installation schedule requirements of approximately one cryomodule per month per laboratory. Fermilab is at half point for the production, meaning that 6 cryomodules are fully assembled and tested. This paper presents Fermilab Cryomodule Assembly Facility (CAF) infrastructure for the LCLS-II cryomodules assembly, production experience at the half point emphasizing the challenges and mitigations.

43 PARTICLE ACCELERATORS↗

3.9 GHz Power Coupler Design and Tests for LCLS-II Project

LCLS-II linac requires two 3.9 GHz cryomodules (eight cavities per CM), operating up to 16MV/m in cw regime. Fermilab has designed and built few prototypes of the cavity and auxiliaries and tested them at the vertical and horizontal cryostats. Fundamental power coupler, based on existing design (FLASH, XFEL) was redesign for 2kW average power. We built three prototypes and tested them at room temperature test stand. One coupler was assembled on the cavity and tested at horizontal cryostat as part of design verification program. Test results and comparison with simulations are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Design and Test Results of the 3.9 GHz Cavity for LCLS-II

The LCLS-II project uses sixteen 3.9 GHz superconduct-ing cavities to linearize energy distribution before the bunch compressor. To meet LCLS-II requirements origi-nal FNAL design used in FLASH and XFEL was signifi-cantly modified to improve performance and provide reliable operation up to 16 MV/m in cw regime [1-3]. Four prototype cavities were built and tested at vertical cryo-stat. After dressing, one cavity was assembled and tested at horizontal cryostat as part of design verification pro-gram. All auxiliaries (magnetic shielding, power and HOM couplers, tuner) were also re-designed and tested with this cavity. In this paper we will discuss cavity and coupler design and test results.

43 PARTICLE ACCELERATORS↗

Superconducting multi-cell trapped mode deflecting cavity

A method and system for beam deflection. The method and system for beam deflection comprises a compact superconducting RF cavity further comprising a waveguide comprising an open ended resonator volume configured to operate as a trapped dipole mode; a plurality of cells configured to provide a high operating gradient; at least two pairs of protrusions configured for lowering surface electric and magnetic fields; and a main power coupler positioned to optimize necessary coupling for an operating mode and damping lower dipole modes simultaneously.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monopole HOMs Dumping in the LCLS-II 1.3 GHz Structure

Developing an upgrade of Linac Coherent Light Source (LCLS-II) is currently underway. The central part of LCLS-II is a continuous wave superconducting RF (CW SRF) electron linac. High order modes (HOMs) excited in SRF structures by passing beam may deteriorate beam quality and affect beam stability. In this paper we report the simulation results of monopole High Order Modes (HOM) spectrum in the 1.3 GHz accelerating structure. Optimum parameters of the HOM feedthrough are suggested for minimizing RF losses on the HOM antenna tip and for preserving an efficiency of monopole HOMs damping simultaneously.

43 PARTICLE ACCELERATORS↗

Redesign of the End Group in the 3.9 GHz LCLS-II Cavity

Development and production of Linac Coherent Light Source II (LCLS-II) is underway. The central part of LCLS-II is a continuous wave superconducting RF (CW SCRF) electron linac. The 3.9 GHz third harmonic cavity similar to the XFEL design will be used in LCLS-II for linearizing the longitudinal beam profile*. The initial design of the 3.9 GHz cavity developed for XFEL project has a large, 40 mm, beam pipe aperture for better higher-order mode (HOM) damping. It is resulted in dipole HOMs with frequencies nearby the operating mode, which causes difficulties with HOM coupler notch filter tuning. The CW linac operation requires an extra caution in the design of the HOM coupler in order to prevent its possible overheating. In this paper we present the modified 3.9 GHz cavity End Group for meeting the LCLS-II requirements

43 PARTICLE ACCELERATORS↗

Commissioning And First Results From The Fermilab Cryomodule Test Stand

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

43 PARTICLE ACCELERATORS↗

Preliminary Measurement of the Transfer Matrix of a TESLA-type Cavity at FAST

Superconducting linacs are capable of producing intense, ultra-stable, high-quality electron beams that have widespread application in Science and Industry. Many current and planned projects employ 1.3-GHz 9-cell superconducting cavities of the TESLA design*. In the present paper we discuss the transverse-focusing properties of such a cavity and non-ideal transverse-map effects introduced by field asymmetries in the vicinity of the input and high-order-mode radiofrequency (RF) couplers**. We especially consider the case of a cavity located downstream of an RF-gun in a setup similar to the photoinjector of the Fermilab Accelerator Science and Technology (FAST) facility. Preliminary experimental measurements of the CC2 cavity transverse matrix were carried out at the FAST facility. The results are discussed and compared with analytical and numerical simulations.

43 PARTICLE ACCELERATORS↗

Coherent Effects of High Current Beam in Project-X Linac

Resonance excitation of longitudinal high order modes in superconducting RF structures of Project-X continuous wave linac is studied. We analyze regimes of operation of the linac with high beam current, which can be used to provide an intense muon source for the future Neutrino Factory or Muon Collider, and also important for the Accelerator-Driven Subcritical systems. We calculate power loss and associated heat load to the cryogenic system. Longitudinal emittance growth is estimated. We consider an alternative design of the elliptical cavity for the high energy part of the linac, which is more suitable for high current operation.

43 PARTICLE ACCELERATORS↗

Study of Coupler's Effects on ILC Like Lattice

It is well known that insertion of a coupler into a rf cavity breaks the rotational symmetry of the cavity, resulting in an asymmetric field. This asymmetric field results in a transverse RF Kick. This RF kick transversely offsets the bunch from the nominal axis & it depends on the longitudinal position of the particle in the bunch. Also, insertion of coupler generates short range transverse wake field which is independent from the transverse offset of the particle. These effects cause emittance dilution and it is thus important to study their behaviour & possible correction mechanisms. These coupler effects, i.e. coupler’s RF kick & coupler's wake field are implemented in a beam dynamics program, Lucretia. Simulations are performed for main linac & bunch compressor of International Linear Collider (ILC) like lattices. Results are compared with analytical results and another beam dynamics code Placet. The good agreement has been achieved.

43 PARTICLE ACCELERATORS↗

Optimization of End Cells of Low Beta Cavity of Higher Energy Part of Project X

11 cell elliptical cavity is designed for acceleration of particles travelling at 81 % of the speed of light. It will operate at 1.3 GHz & will be served to accelerate the particles from 0.450 GeV to 1.2 GeV in high energy section of Project-X. The cavity is studied for higher order mode (HOM) & trapped modes. The shapes of end cells of cavity is optimized to increase the field amplitude in end cells so that coupling of trapped modes may increase with HOM coupler & they can be extracted easily but keeping the field flatness & operating frequency undisturbed.

43 PARTICLE ACCELERATORS↗

Single Spoke Cavities for Low-energy Part of CW Linac of Project X.

In the low-energy part of the Project X H-linac three families of 325 MHz SC single spoke cavities will be used, having {beta} = 0.11, 0.21 and 0.4. Single spoke cavity was selected for the linac because of higher r/Q. Results of optimization of all cavities are presented. Results of the beam dynamics optimization for initial stage of the linac with beta=0.11 single spoke cavity are presented at poster MOPEC082 (this conference).

43 PARTICLE ACCELERATORS↗

Final Results on RF and Wake Kicks Caused by the Couplers for the ILC Cavity

In the paper the results are presented for calculation of the transverse wake and RF kick from the power and HOM couplers of the ILC acceleration structure. The RF kick was calculated stand-alone by HFSS, CST MWS and COMSOL codes while the wake kick was calculated by GdfidL. The calculation precision and convergence for both cases are discussed and compared to the results obtained independently by other group.

43 PARTICLE ACCELERATORS↗

The variable input coupler for the Fermilab Vertical Cavity Test Facility

A variable input coupler has been designed for the Fermilab vertical cavity test facility (VCTF), a facility for CW RF vertical testing of bare ILC 1.3 GHz 9-cell SRF cavities at 2K, to provide some flexibility in the test stand RF measurements. The variable coupler allows the cavity to be critically coupled for all RF tests, including all TM010 passband modes, which will simplify or make possible the measurement of those modes with very low end-cell fields, e.g., {pi}/9 mode. The variable coupler assembly mounts to the standard input coupler port on the cavity, and uses a cryogenic motor submerged in superfluid helium to control the antenna position. The RF and mechanical design and RF test results are described.

43 PARTICLE ACCELERATORS↗