Single-Event Effects Test Report Texas Instruments, OPA842 Low-Noise Operational Amplifier

Testing was done to characterize the Texas Instruments Operational Amplifiers OPA842 single event effects (SEE) response. The primary SEE concerns for this device are single event latchup (SEL) and single event transients (SETs). Testing focused on determining susceptibility to SEL and characterizing the SET response. Testing occurred on November 11, 2022.

Kaitlyn L Ryder↗

Single-Event Effect Test Report Analog Devices LTC1604AIG#90117 ADC

This study is to characterize the destructive single-event latchup (SEL) susceptibility of the LTC1604AIG#90117 (LTC1604) analog/digital converter (ADC). The device was monitored for SEL current events on the power supplies during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory (LBNL) 88-inch Cyclotron. Testing was performed on September 11, 2021.