Search NASA⌕ Search

Engineering topics

McNaney, J. M.

Publications and source records attributed to McNaney, J. M..

At least 19 records

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Ramp compression of tantalum to multiterapascal pressures: Constraints of the thermal equation of state to 2.3 TPa and 5000 K

We report measurements of the compressibility of ramp compressed tantalum to a final stress of 2.3 TPa corresponding to threefold volumetric compression. Using these data, we extended the experimental constraint on the Ta cold compression curve by an order of magnitude in pressure. Furthermore, by combining the resulting data with previous measurements of shock compression and ambient pressure heating, we construct an experimentally bounded and thermodynamically consistent equation of state model for Ta which has 2% uncertainty in pressure at 1 TPa. We therefore propose Ta as an in situ pressure scale for laser-heated static compression experiments which were recently able to reach terapascal pressures and thousands of degrees Kelvin. Our new equation of state of Ta is experimentally constrained at extreme pressures and temperatures relevant to a wide range of planetary interiors and will allow for more accurate comparison between experimental measurements and theory at extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Metastability of Liquid Water Freezing into Ice VII under Dynamic Compression

The ubiquitous nature and unusual properties of water have motivated many studies on its metastability under temperature- or pressure-induced phase transformations. Here, nanosecond compression by a high-power laser is used to create the nonequilibrium conditions where liquid water persists well into the stable region of ice VII. Through our experiments, as well as a complementary theoretical/computational analysis based on classical nucleation theory, we report that the metastability limit of liquid water under nearly isentropic compression from ambient conditions is at least 8 GPa, higher than the 7 GPa previously reported for lower loading rates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Establishing gold and platinum standards to 1 terapascal using shockless compression

New techniques are advancing the frontier of high-pressure physics beyond 1 terapascal, leading to new discoveries and offering stringent tests for condensed-matter theory and advanced numerical methods. However, the ability to absolutely determine the pressure state remains challenging, and well-calibrated pressure-density reference materials are required. We conducted shockless dynamic compression experiments at the National Ignition Facility and the Z machine to obtain quasi-absolute, high-precision, pressure-density equation-of-state data for gold and platinum. We derived two experimentally constrained pressure standards to terapascal conditions. Establishing accurate experimental determinations of extreme pressure will facilitate better connections between experiments and theory, paving the way toward improving our understanding of material response to these extreme conditions.

36 MATERIALS SCIENCE↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Metastability of diamond ramp-compressed to 2 terapascals

Carbon is the fourth-most prevalent element in the Universe and essential for all known life. In the elemental form it is found in multiple allotropes, including graphite, diamond and fullerenes, and it has long been predicted that even more structures can exist at pressures greater than those at Earth’s core. Several phases have been predicted to exist in the multi-terapascal regime, which is important for accurate modelling of the interiors of carbon-rich exoplanets. By compressing solid carbon to 2 terapascals (20 million atmospheres; more than five times the pressure at Earth’s core) using ramp-shaped laser pulses and simultaneously measuring nanosecond-duration time-resolved X-ray diffraction, we found that solid carbon retains the diamond structure far beyond its regime of predicted stability. The results confirm predictions that the strength of the tetrahedral molecular orbital bonds in diamond persists under enormous pressure, resulting in large energy barriers that hinder conversion to more-stable high-pressure allotropes, just as graphite formation from metastable diamond is kinetically hindered at atmospheric pressure. In conclusion, this work nearly doubles the highest pressure at which X-ray diffraction has been recorded on any material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimized continuum x-ray emission from laser-generated plasma

We study continuum x-ray emission from hot plasma at the National Ignition Facility (NIF). We find that the x-ray yield in the multi-keV photon energy range is larger in Ti than in Ag or Au. This apparent paradox is due to Ti K-shell vacancies generated by the extraordinary energy density achieved by the NIF lasers. This is supported by direct observations of large continuum enhancement above the Ti K-series limit due to both free–bound (recombination) emission and strong Ly α (H-like) emission. Detailed calculations agree well with our measurements and support our conclusions. <!--/abstract content--><!--fulltext content--> X-ray emission from matter pervades the universe and plays an important role in the high-energy density (HED) regime (~10 5 J/cm 3 ). For example, the emission and absorption of x-rays controls the thermal state and evolution of stellar interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

X-ray diffraction at the National Ignition Facility

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2 θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2 θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2–7 on the periodic table.

47 OTHER INSTRUMENTATION↗

Extreme Hardening of Pb at High Pressure and Strain Rate

We study the high-pressure strength of Pb and Pb-4wt%Sb at the National Ignition Facility. We measure Rayleigh-Taylor growth of preformed ripples ramp compressed to ~400 GPa peak pressure, among the highest-pressure strength measurements ever reported on any platform. We find agreement with 2D simulations using the Improved Steinberg-Guinan strength model for body-centered-cubic Pb; the Pb-4wt%Sb alloy behaves similarly within the error bars. Here, the combination of high-rate, pressure-induced hardening and polymorphism yield an average inferred flow stress of ~3.8 GPa at high pressure, a ~250-fold increase, changing Pb from soft to extremely strong.

36 MATERIALS SCIENCE↗

Neutron Time-of-Flight Measurements of Charged-Particle Energy Loss in Inertial Confinement Fusion Plasmas

Neutron spectra from secondary 3 H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. Furthermore, these new data and their sensitivity to the energy loss of fast tritons emitted from thermal 2 H(d,p) 3 H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k B T ≈ 1–4 keV and particle densities of n ≈ (12–2) × 10 24 cm –3 . Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refractive index of lithium fluoride to 900 gigapascal and implications for dynamic equation of state measurements

Lithium fluoride (LiF) is a unique crystal possessing the largest reported bandgap of any material and is predicted to remain transparent to visible light under stresses in excess of 1000 GPa. Dynamic compression experiments often utilize LiF as a window material to maintain stress on a sample while enabling direct measurements of interface velocity. However, typical velocimetry diagnostics measure changes in the optical path length; therefore, an accurate understanding of LiF’s equation of state and refractive index is needed. Here, we present a measurement of the LiF refractive index up to 900 GPa from a low-temperature ramp-compression experiment at the National Ignition Facility. To demonstrate propagation of optical uncertainty from this work to equation of state measurements, simulations in which a tin–LiF interface reaches a peak stress of 825 GPa show that the principal isentrope of tin can be determined up to 1450 GPa with a 1.2% uncertainty in density while considering uncertainties in the optical response of LiF.

36 MATERIALS SCIENCE↗

Investigation of ion kinetic effects in direct-drive exploding-pusher implosions at the NIF

Measurements of yield, ion temperature, areal density (rhoR), shell convergence, and bang time have been obtained in shock-driven, D2 and D3He gas-filled “exploding-pusher” inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF) to assess the impact of ion kinetic effects. These measurements probed the shock convergence phase of ICF implosions, a critical stage in hot-spot ignition experiments. The data complement previous studies of kinetic effects in shock-driven implosions. Ion temperature and fuel rhoR inferred from fusion-product spectroscopy are used to estimate the ion-ion mean free path in the gas. A trend of decreasing yields relative to the predictions of 2D draco hydrodynamics simulations with increasing Knudsen number (the ratio of ion-ion mean free path to minimum shell radius) suggests that ion kinetic effects are increasingly impacting the hot fuel region, in general agreement with previous results. The long mean free path conditions giving rise to ion kinetic effects in the gas are often prevalent during the shock phase of both exploding pushers and ablatively-driven implosions, including ignition-relevant implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY18 LLNL Experimental Programs at Omega

In Fiscal Year 2018 (FY18), Lawrence Livermore National Laboratory’s (LLNL’s) High Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted numerous campaigns on the OMEGA and OMEGA-EP (EP) laser systems. This was the 20th year of National Lab collaborative experiments at OMEGA since the Nova Laser at LLNL shut down in 1999 [1], building upon prior collaborations. In FY18 overall, these LLNL programs led 465 target shots, with 283 shots using just the OMEGA laser system, 172 shots using just the EP laser system, and 10 Joint shots using both lasers together. Approximately 28% of the total number of shots (60 OMEGA shots and 71 EP shots) supported the Indirect Drive Inertial Confinement Fusion Campaign. The remaining 72% (223 OMEGA-only shots, 101 EP-only shots and 10 Joint shots) were dedicated to experiments for High-Energy-Density Physics. Highlights of the various HED and ICF-ID campaigns are summarized in the following reports. In addition to these experiments, LLNL Principal Investigators (PIs) led a variety of Laboratory Basic Science campaigns using OMEGA and EP, including 99 target shots using just OMEGA and 39 shots using just EP. The highlights of these are also summarized, following the ICF and HED campaigns. Overall, LLNL PIs led a total of 603 shots at LLE in FY 2018. In addition, LLNL PIs supported 47 NLUF shots on Omega and 31 NLUF shots on EP in collaboration with the academic community.

36 MATERIALS SCIENCE↗

Bremsstrahlung x-ray generation for high optical depth radiography applications on the National Ignition Facility [Bremsstrahlung x-ray generation for opacity radiography applications on the National Ignition Facility]

Here, we have tested a set of x-ray sources for use as probes of highly attenuating, laser-driven experiments on the National Ignition Facility (NIF). Unlike traditional x-ray sources that optimize for a characteristic atomic transition (often the n = 2 → n = 1 transition in ionized, He-like atoms), the design presented here maximizes the total photon flux by optimizing for intense, broadband Bremsstrahlung radiation. Three experiments were performed with identical targets, including a uranium x-ray source foil and a tungsten substrate with a narrow (25 μm wide) collimating slit to produce a quasi-1D x-ray source. Two experiments were performed using 12 beams from the NIF laser, each delivering approximately 46 kJ of laser energy but with different laser spatial profiles. This pair yielded similar temporal x-ray emission profiles, spatial resolution, and inferred hot electron temperature. A third experiment with only 6 beams delivering approximately 25 kJ produced a lower hot electron temperature and significantly lower x-ray flux, as well as poorer spatial resolution. The data suggest that laser pointing jitter may have affected the location and intensity of the emitting plasma, producing an emission volume that was not well centered behind the collimating slit and lower intensity than designed. However, the 12-beam design permits x-ray radiography through highly attenuating samples, where lower energy line-emission x-ray sources would be nearly completely attenuated.

47 OTHER INSTRUMENTATION↗

Characterizing the modulation transfer function for X-ray radiography in high energy density experiments

Here, the Modulation Transfer Function ( MTF ) is an established means for characterizing imaging performance of X-ray radiography systems. We report on experiments using high energy, laser-driven X-ray radiography systems that assess performance using MTF values measured with the knife-edge projection method. The broadband, hard X-ray systems under study use line-projection imaging produced by narrowing the laser-generated X-ray source with a slit. We find that good contrast resolution can be achieved (the MTF = 0.5 at 75 μm wavelength) and that this performance is reproduced on different laser facilities. We also find that the MTF is sensitive both to the thickness of the line-projection slit and to the backing material thickness under the knife-edge. Both these sensitivities are due to a common mechanism, namely induced changes in the spectrally-averaged spatial widths of the X-ray source. The same line-projection system is also used on experimental campaigns measuring Rayleigh-Taylor instability growth by dynamically imaging sinusoidal, high Z micro-targets with wavelengths of 100 μm or less. By applying the measured MTF values to correct the ripple target contrast measurements, we can predict ripple growth to approximately 10% accuracy.

47 OTHER INSTRUMENTATION↗

Developing a high-flux, high-energy continuum backlighter for extended x-ray absorption fine structure measurements at the National Ignition Facility

Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for in situ characterization of matter in the high energy density regime. An EXAFS platform is currently being developed on the National Ignition Facility. Development of a suitable X-ray backlighter involves minimizing the temporal duration and source size while maximizing spectral smoothness and brightness. One approach involves imploding a spherical shell, which generates a high-flux X-ray flash at stagnation. Furthermore we present results from a series of experiments comparing the X-ray source properties produced by imploded empty and Ar-filled capsules.

47 OTHER INSTRUMENTATION↗