Search NASA⌕ Search

DOE OSTI · 1618417

X-ray diffraction at the National Ignition Facility

Abstract

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2 θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2 θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2–7 on the periodic table.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rygg, J. R., Smith, R. F., Lazicki, A. E., Braun, D. G., Fratanduono, D. E., Kraus, R. G., McNaney, J. M., Swift, D. C., Wehrenberg, C. E., Coppari, F., Ahmed, M. F., Barrios, M. A., Blobaum, K. J. M., Collins, G. W., Cook, A. L., Di Nicola, P., Dzenitis, E. G., Gonzales, S., Heidl, B. F., Hohenberger, M., House, A., Izumi, N., Kalantar, D. H., Khan, S. F., Kohut, T. R., Kumar, C., Masters, N. D., Polsin, D. N., Regan, S. P., Smith, C. A., Vignes, R. M., Wall, M. A., Ward, J., Wark, J. S., Zobrist, T. L., Arsenlis, A., Eggert, J. H.. 2020-04-21. X-ray diffraction at the National Ignition Facility. https://doi.org/10.1063/1.5129698

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗