Search NASASearch

Engineering topics

Mcgillem, C. D.

Publications and source records attributed to Mcgillem, C. D..

At least 19 records

Spatial Resolution Estimation of LANDSAT-4 Thematic Mapper Data

The problem of estimating the overall point-spread function (PSF) of multispectral scanner systems was studied using real scene data and known geometric structures in the scene. A direct solution to an approximate form of the PSF was made along with a method using the derivative of an estimated edge response. Both results agreed closely. The TM scanner system specifications are given in line-spread function width and these values are listed with the experimental results in terms of meters. The estimated values are very reasonable, considering the number of factors which could be influencing the result. The atmosphere will have a blurring effect on the overall PSF as well as on cubic convolution resampling effects and possible electronic effects not accounted for in the specification. Also, the specific definition of the LSF specification is not known nor is the actual altitude at the instant the data were acquired. Thus the nominal overall PSF half-amplitude width of 39 m is reasonable; however, a greater sample of scene objects should be evaluated to furthur verify this result.

Mcgillem, C. D.

LANDSAT-4/5 image data quality analysis

A LANDSAT Thematic Mapper (TM) quality evaluation study was conducted to identify geometric and radiometric sensor errors in the post-launch environment. The study began with the launch of LANDSAT-4. Several error conditions were found, including band-to-band misregistration and detector-to detector radiometric calibration errors. Similar analysis was made for the LANDSAT-5 Thematic Mapper and compared with results for LANDSAT-4. Remaining band-to-band misregistration was found to be within tolerances and detector-to-detector calibration errors were not severe. More coherent noise signals were observed in TM-5 than in TM-4, although the amplitude was generally less. The scan direction differences observed in TM-4 were still evident in TM-5. The largest effect was in Band 4 where nearly a one digital count difference was observed. Resolution estimation was carried out using roads in TM-5 for the primary focal plane bands rather than field edges as in TM-4. Estimates using roads gave better resolution. Thermal IR band calibration studies were conducted and new nonlinear calibration procedures were defined for TM-5. The overall conclusion is that there are no first order errors in TM-5 and any remaining problems are second or third order.

Malaret, E.

LANDSAT-4 MSS and Thematic Mapper data quality and information content analysis

LANDSAT-4 thematic mapper (TM) and multispectral scanner (MSS) data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and supervised classifiers on test data. A detailed spectral class analysis (multispectral classification) was carried out to compare the information content of the MSS and TM for a large number of scene classes. A temperature-mapping experiment was carried out for a cooling pond to test the quality of thermal-band calibration. Overall TM data quality is very good. The MSS data are noisier than previous LANDSAT results.

Anuta, P.

LANDSAT-4 MSS and TM Spectral Class Comparison and Coherent Noise Analysis

A detailed spectral analysis is conducted of thematic mapper and MSS data for an area near Des Moines, Iowa. Data are utilized from 7 blocks distributed throughout the area which included agricultural, forest, suburan, urban, and water scene types. The blocks are processed using a clustering algorithm to produce up to 18 cluster groupings for each block. Each cluster class is then identified with a ground-cover class using aerial photography and maps of the area. The clusters from each of the 7 blocks are inspected with regard to separability, mean, and variances. The separability measure used in the transformed divergence function or processor measures the statistical distance between classes based on class means and covariance matrices. The measure has a maximum value of 2,000 and the minimum of 0. Spectrally, very close classes will typically have values as low as 50 to 500.

Anuta, P. E.

Spatial Resolution Estimation of LANDSAT-4 TM Data

Experiments to determine overall radiometric resolution are discussed. Scene structures, such as roads and field edges, are used with numerical estimation procedures to predict resolution in LANDSAT 4 Thematic Mapper imagery. A nominal resolution of 39 meters is determined rather than the predicted 30 meter prelaunch estimates.

Mcgillem, C. D.

Landsat-4 MSS and Thematic Mapper data quality and information content analysis

Landsat-4 Thematic Mapper and Multispectral Scanner data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic Mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and numerous supervised classifiers on data from Iowa and Illinois. A detailed spectral class analysis (multispectral classification) was carried out on data from the Des Moines, IA area to compare the information content of the MSS and TM for a large number of scene classes.

Anuta, P. E.

Evaluation of Landsat-4 Thematic Mapper and multispectral scanner data quality

Landsat-4 image data quality was evaluated for test sites in Iowa and Illinois. Radiometric and geometric quality was tested and an applications evaluation was carried out using a cooling-pond thermal-mapping example. Geometric quality was found to be generally very good. Small errors were found in registration of the middle IR bands of the TM and the thermal IR band was found to be misregistered by one 120-meter pixel. Radiometric quality of the TM is excellent with only minor striping effects.

Bartolucci, L. A.

Resolution estimation for the Landsat-4 Thematic Mapper

Satellite-based multispectral imaging systems have been in operation since 1972 and the latest in the Landsat series of sensors was launched in July 1982. One system parameter of interest is resolution and this paper discusses experiments to determine the actual overall resolution after launch. Experimental results for the spatial resolution estimation of bands four and five of the Landsat-D Thematic Mapper are presented here.

Mcgillem, C. D.

Spatial resolution estimation of LANDSAT-4 TM and MSS data

In order to verify that the LANDSAT-4 sensors are operating within specifications, it is useful to estimate the system parameters by analysis of the measured data. One parameter of particular interest is the sensor point-spread function (PSF) which determines the resolution of the system. A method of estimating the PSF is described that utilizes data obtained during scanning of ground elements having identifiable geometric and radiometric structure. These data are then processed in such a manner as to recover either the PSF itself or to estimate the parameters of an assumed functional representation of the PSF.

Mcgillem, C. D.

Estimation of a remote sensing system point-spread function from measured imagery

A general approach to identifying the point spread function (PSF) of a remotely sensed scene is demonstrated in terms of a step function for an abrupt change in the gray level along the row or column of the image data. The estimate of the PSF is made in terms of a finite sum of basis functions, employing a sequence of rectangular pulses covering the spatial extent of the PSF. The approximation, if narrow impulses are employed, provides accurate fidelity to the PSF. The method becomes practical when the geometrical structure of the scene elements producing the measured response is known. The field boundary is obtained through consideration of the differing intensities on each side of the boundary, which is a step discontinuity. The mathematical procedure for the technique is provided, together with a sample problem from Landsat-4 Thematic Mapper data. Atmospheric blurring and electronic effects on the overall PSF and the cubic convolution resampling effects are noted.

Mcgillem, C. D.

Multiclass Bayes error estimation by a feature space sampling technique

A general Gaussian M-class N-feature classification problem is defined. An algorithm is developed that requires the class statistics as its only input and computes the minimum probability of error through use of a combined analytical and numerical integration over a sequence simplifying transformations of the feature space. The results are compared with those obtained by conventional techniques applied to a 2-class 4-feature discrimination problem with results previously reported and 4-class 4-feature multispectral scanner Landsat data classified by training and testing of the available data.

Mobasseri, B. G.

A parametric model for multispectral scanners

A set of test statistics are specified and the corresponding output quantities computed by the characteristic function. Two sets of classification accuracies, one at the input and one at the output are estimated. The scanner's instantaneous field of view is changed and the variation of the output classification performance is monitored.

Mobasseri, B. G.

Multispectral scanner system parameter study and analysis software system description, volume 2

The author has identified the following significant results. The integration of the available methods provided the analyst with the unified scanner analysis package (USAP), the flexibility and versatility of which was superior to many previous integrated techniques. The USAP consisted of three main subsystems; (1) a spatial path, (2) a spectral path, and (3) a set of analytic classification accuracy estimators which evaluated the system performance. The spatial path consisted of satellite and/or aircraft data, data correlation analyzer, scanner IFOV, and random noise model. The output of the spatial path was fed into the analytic classification and accuracy predictor. The spectral path consisted of laboratory and/or field spectral data, EXOSYS data retrieval, optimum spectral function calculation, data transformation, and statistics calculation. The output of the spectral path was fended into the stratified posterior performance estimator.

Landgrebe, D. A.

A parametric multiclass Bayes error estimator for the multispectral scanner spatial model performance evaluation

The author has identified the following significant results. The probability of correct classification of various populations in data was defined as the primary performance index. The multispectral data being of multiclass nature as well, required a Bayes error estimation procedure that was dependent on a set of class statistics alone. The classification error was expressed in terms of an N dimensional integral, where N was the dimensionality of the feature space. The multispectral scanner spatial model was represented by a linear shift, invariant multiple, port system where the N spectral bands comprised the input processes. The scanner characteristic function, the relationship governing the transformation of the input spatial, and hence, spectral correlation matrices through the systems, was developed.

Mobasseri, B. G.

Image registration - Similarity measure and preprocessing method comparisons

An experimental comparison of several similarity measures and preprocessing techniques used for the registration of temporally differing images is carried out. It is found that preprocessing of the images via a gradient operator improves the registration performance. This is in agreement with a derived optimal processor based upon image and temporal difference characteristics.

Svedlow, M.

Optimum constrained image restoration filters

The research described centered on development of an optimum image restoration filter (IRF) minimizing the radius of gyration of the corrected or composite system point-spread function (P-SF) subject to contraints, and reducing 2-dimensional spatial smearing or blurring of an image. The constraints are imposed on the radius of gyration of the IRF P-SF, the total restored image noise power, and the shape of the composite system frequency spectrum. The image degradation corresponds to mapping many points from the original image into a single resolution element. The P-SF is obtained as solution to a set of simultaneous differential equations obeying nonlinear integral constraints. Truncation errors due to edge effects are controlled by constraining the radius of gyration of the IRF P-SF. An iterative technique suppresses sidelobes of the composite system P-SF.

Riemer, T. E.

Image registration error variance as a measure of overlay quality

When one image (the signal) is to be registered with a second image (the signal plus noise) of the same scene, one would like to know the accuracy possible for this registration. This paper derives an estimate of the variance of the registration error that can be expected via two approaches. The solution in each instance is found to be a function of the effective bandwidth of the signal and the noise, and the signal-to-noise ratio. Application of these results to LANDSAT-1 data indicates that for most cases, registration variances will be significantly less than the diameter of one picture element.

Mcgillem, C. D.