High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Strategies for on-chip digital data compression for X-ray pixel detectors

Here, the continued desire for X-ray pixel detectors with higher frame rates will stress the ability of application-specific integrated circuit (ASIC) designers to provide sufficient off-chip bandwidth to reach continuous frame rates in the 1 MHz regime. To move from the current 10 kHz to the 1 MHz frame rate regime, ASIC designers will continue to pack as many power-hungry high-speed transceivers at the periphery of the ASIC as possible. In this paper, however, we present new strategies to make the most efficient use of the off-chip bandwidth by utilizing data compression schemes for X-ray photon-counting and charge-integrating pixel detectors. In particular, we describe a novel in-pixel compression scheme that converts from analog to digital converter units to encoded photon counts near the photon Poisson noise level and achieves a compression ratio of >1.5x independent of the dataset. In addition, we describe a simple yet efficient zero-suppression compression scheme called "zeromask" (ZM) located at the ASIC's edge before streaming data off the ASIC chip. ZM achieves average compression ratios of >4x, >7x, and >8x for high-energy X-ray diffraction, ptychography, and X-ray photon correlation spectroscopy datasets, respectively. We present the conceptual designs, register-transfer level block diagrams, and the physical ASIC implementation of these compression schemes in 65 nm CMOS. When combined, these two digital compression schemes could increase the effective off-chip bandwidth by a factor of 6-12x.

47 OTHER INSTRUMENTATION↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Multi-Element Germanium Detectors with Integrated Readouts

In this study, we have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. Lastly, the detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.

47 OTHER INSTRUMENTATION↗

Multi-element germanium detectors for synchrotron applications

In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of ROACH firmware for microwave multiplexed X-ray TES microcalorimeters

We are developing room temperature electronics based upon the ROACH platform for reading out microwave multiplexed X-ray TES. ROACH is an open-source hardware and software platform featuring a large Xilinx Field Programmable Gate Array (FPGA), Power PC processor, several 10GB Ethernet SFP+ interfaces, and a collection of daughter boards for analog signal generation and acquisition. The combination of a ROACH board, ADC/DAC conversion daughter boards, and hardware for RF mixing allows for the generation and capture of multiple RF tones for reading out microwave multiplexed x-ray TES microcalorimeters. The FPGA is used to generate multiple tones in base band, from 10MHz to 250MHz, which are subsequently mixed to RF in the multiple GHz range and sent through the microwave multiplexer. The tones are generated in the FPGA by storing a large lookup table in Quad Data Rate (QDR) SRAM modules and playing out the waveform to a DAC board. Once the signal has been modulated to RF, passed through the microwave multiplexer, and has been modulated back to base band, the signal is digitized by an ADC board. The tones are modulated to 0Hz by using a FPGA circuit consisting of a polyphase filter bank, several Xilinx FFT blocks, Xilinx CORDIC blocks (for converting to magnitude and phase), and special phase accumulator circuit for mixing to exactly 0Hz. Upwards of 256 channels can be simultaneously captured and written into a bank of 256 First-In-First-Out (FIFO) memories, with each FIFO corresponding to a channel. Individual channel data can be further processed in the FPGA before being streamed through a 10GB Ethernet fiber-optic interface to a Linux system. The Linux system runs software written in Python and QT C++ for controlling the ROACH system, capturing data, and processing data.

Firmware↗

Tuning the transition temperature of WSi$_{x}$ alloys for use in cryogenic microcalorimeters

Here, microwave kinetic inductance detectors (MKID) provide a pathway to highly multiplexed, high-resolution, detectors. Over the past several years we have introduced the concept of the Thermal Kinetic Inductance Detector (TKID), which operates as a microcalorimeter. As with other microcalorimeters, the thermal noise of a TKID is reduced when the operating temperature is decreased. However, because the sensitivity of a TKID decreases as the operating temperature drops below 20% of T C , the T C of the resonator material must be tuned to match the desired operating temperature. We have investigated the WSi$_{x}$ alloy system as a material for these detectors. By co-sputtering from a Si andW2Si target, we have deposited WSi$_{x}$ films with a tunable T C that ranges from 5 K down to 500 mK. These films provide a large kinetic inductance fraction and relatively low noise levels. We provide results of these studies showing the T C , resistivity, quality factors, and noise as a function of deposition conditions. These results show that WSi$_{x}$ is a good candidate for TKIDs.