Search NASA⌕ Search

Engineering topics

Moody, Kenton J.

Publications and source records attributed to Moody, Kenton J..

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modular, disposable 3D printed microfluidic membrane system for separation and purification

The present disclosure relates to a membrane extraction apparatus for extracting a component from a first liquid. The apparatus may incorporate a housing comprised of first and second mating housing halves, with each housing half having an open faced channel formed therein such that the channels at least partially overlay one another when the two housing halves are secured together. A membrane filter is disposed between the two housing halves to overlay the open faced channels. The membrane filter extracts the component from the first liquid and transfers the component into the second liquid as the first and second liquids flow through the first and second housing halves.

Servis, Anna G.↗

Radiochemical capabilities for astrophysics experiments at the national ignition facility

The Nuclear and Radiochemistry Group at Lawrence Livermore National Laboratory (LLNL) has developed a suite of diagnostics and techniques that can be used for astrophysics experiments at the National Ignition Facility (NIF). Capabilities have been developed to add material to the outside of NIF hohlraum assemblies as well as to the interior of NIF target capsules or the fill gas. The ability to place very small amounts of material close to the NIF target enables activation with very large, short-pulse neutron fluxes. The Solid Radiochemistry Diagnostic can be used to collect solid debris from a NIF shot within 2 h of the execution of a shot, and this can be analyzed for radioactive signatures with or without post-shot chemical processing. The Radiochemical Analysis of Gaseous Samples diagnostic system can be used to collect gaseous products produced during a NIF shot. Capsule doping and radiochemical analysis capabilities at NIF will be discussed. The application of these techniques to astrophysical measurements will be discussed as well as some preliminary results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Transport Modeling of Kinetically Limited Microscale Extraction Systems: Droplet and Supported Liquid Membrane Separations

Microfluidic droplet extraction devices can be used to efficiently measure solute phase transfer kinetics in liquid–liquid extraction systems. In this work, a droplet extraction apparatus was constructed using off-the-shelf and custom 3D printed parts for less than 110 USD. The interfacial kinetics of the transfer of Pu(IV) between an aqueous nitric acid phase and a 5 v/v% tridodecylamine (TDA) in toluene phase were characterized by determining the extent of Pu(IV) transfer between phases at different flow rates. Forward interfacial rate constants calculated from this data using an analytical model are 5.6 × 10 –3 mm s –1 under extraction (aqueous-to-organic solute transfer) conditions and 3.3 × 10 –3 mm s –1 under stripping (organic-to-aqueous solute transfer) conditions. The analytical model is valid when the rate of solute transfer across the interface between the two liquid phases has pseudo-first-order reversible reaction kinetics and is slow relative to the rate of solute transport to the interface. The change in the outlet concentration with residence time determined using the analytical model was compared with the results of a numerical model accounting for advection/diffusion to the interface in addition to kinetically limited interfacial solute transfer. These calculations revealed that for systems with forward interfacial rate constants greater than approximately 10 –2 mm s –1 , the analytical model must be supplemented with a numerical transport model accounting for an additional advection/diffusion mass transfer resistance. This threshold corresponds to a Damköhler number of one. The measured interfacial kinetic rate constants for Pu(IV)/TDA were used in a supported liquid membrane (SLM) numerical model, which showed that the Pu(IV) phase transfer kinetics are fast enough for use in a practical separation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

3D Printed Microfluidic Supported Liquid Membrane Module for Radionuclide Separations

Microfluidic supported liquid membrane extraction is a promising technique for microliter-scale radionuclide separations because it requires very small reagent volumes and combines extraction and stripping in a single unit operation. Flat sheet supported liquid membrane (FS-SLM) modules with 100, 200, 300, and 400 μm deep channels were fabricated at a cost of less than 5 USD in material using a commercially available resin three-dimensional (3D) printer. The performance of these modules was characterized by quantifying uranium transport across a 15 v/v% tributyl phosphate (TBP) liquid membrane at flow rates between 5 and 60 μL min –1 and developing a two-dimensional (2D) numerical transport model for the system. The extent of uranium extraction was found to increase with increasing residence time and decreasing channel depth, with quantitative extraction occurring at the slowest flow rates and shallowest channel depths. The numerical model agreed well with the experimental extraction results. Time-dependent calculations showed that the modules reach steady state in fewer than 9 min and that there is a considerable buildup of uranium in the membrane during that time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Studies of the homologs and pseudo-homologs of flerovium with crown ether based extraction chromatography resins

A crown-ether based extraction chromatography resin, Eichrom Pb, has been characterized for separations of the flerovium (Fl) pseudo-homolog Hg. Previous results on the batch uptake of Pb(II) and Sn(IV) are compared with newly investigated Hg(II) in HCl matrices. It was determined that all three elements can be strongly retained by the resin at different HCl concentrations. To assess the feasibility for performing an experiment on the chemical properties of Fl using this resin the extraction kinetics were studied. In conclusion, a separation method for the isolation of the homologs Pb(II) and Sn(IV) and pseudo-homolog Hg(II) has been established using 2 mL pre-packed Pb resin columns under vacuum flow.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of a 212 Pb and 212 Bi generator for homolog studies of flerovium and moscovium

A simple generator using AG 50 Wx8 cation exchange resin has been developed for continual elution of 212 Pb and 212 Bi from the parent radionuclide 228 Th, derived from 232 U. Using 0.4 M HCl as an eluent will elute 212 Bi while 212 Pb is eluted with 2 M HCl. The generator has shown good reproducibility of elution bands. A generator set-up in 2013 has been in continual use over 4 years demonstrating that this generator system has a long and stable lifetime. Furthermore, the generator system presented here has served as a long-term method for attaining no-carrier-added 212 Pb and 212 Bi radionuclides for homolog studies of flerovium and moscovium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the homologs of flerovium with crown ether based extraction chromatography resins: studies in nitric acid

Eichrom’s Pb resin, a crown-ether-based extraction chromatography resin, was characterized for separation of the flerovium (Fl) homologs, Pb and Sn. Batch uptake of Pb(II) and Sn(IV) radionuclides was determined from an HNO 3 matrix. Pb(II) was strongly retained on the resin at all HNO 3 concentrations, while Sn(IV) showed no uptake. Extraction kinetics for Pb(II) were examined and show suitable uptake on the second time scale. Here, separation methods for the isolation of individual homologs, Pb(II) and Sn(IV), have been established using 2 mL pre-packed vacuum flow Pb resin columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Smuggling International Technical Working Group (ITWG): Round Robin #3 (Final Report)

Full nuclear forensics analysis of the two samples is complete. All uranium isotopic analyses indicate that both samples are weapons-usable, highly enriched uranium. Therefore, both seizures indicate that the statutes of the country of Texmex regarding the transport of uranium materials have been violated (>1 gram, >1% enriched in U235). Isotopic analysis by multicollector inductively coupled plasma-mass spectrometry (MC-ICP-MS) indicates that the two samples (Sample A, Sample B) have isotopic compositions that differ outside analytical uncertainty (k=2). The model ages of the two samples (apparent time since last chemical separation of parent and daughter nuclides) also differ outside analytical uncertainty (k=2). These results would indicate that, even with all of the other similarities between the two samples, the two questioned samples originate from different source materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗