Addressing the Challenge of Electrochemical Ionomer Oxidation in Future Anion Exchange Membrane Water Electrolyzers

Hydrogen production through anion-exchange membrane water electrolyzers (AEMWEs) offers cost advantages over proton-exchange membrane counterparts, mainly due to the good oxygen evolution reaction (OER) activity of platinum-group-metal-free catalysts in alkaline environments. However, the electrochemical oxidation of ionomers at the OER catalyst interface can decrease the local electrode pH, which limits AEMWE performance. Various strategies at the single-cell-level have been explored to address this issue. Here, this work reviews the current understanding of electrochemical ionomer oxidation and strategies to mitigate it, providing our perspective on each approach. Our analysis highlights the competitive adsorption strategy as particularly promising for mitigating ionomer oxidation. This Perspective also outlines future directions for advancing high-performance alkaline AEMWEs and other energy devices using hydrocarbon ionomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double-Atom Catalysts Featuring Inverse Sandwich Structure for CO 2 Reduction Reaction: A Synergetic First-Principles and Machine Learning Investigation

Electrocatalytic CO 2 reduction reactions (CO 2 RR) based on scalable and highly efficient catalysis provide an attractive strategy for reducing CO 2 emissions. Here in this work, we combined first-principles density functional theory (DFT) and machine learning (ML) to comprehensively explore the potential of double-atom catalysts (DACs) featuring an inverse sandwich structure anchored on defective graphene (gra) to catalyze CO 2 RR to generate C 1 products. We started with five homonuclear M 2 ⊥gra (M = Co, Ni, Rh, Ir, and Pt), followed by 127 heteronuclear MM'⊥gra (M = Co, Ni, Rh, Ir, and Pt, M' = Sc–Au). Stable DACs were screened by evaluating their binding energy, formation energy, and dissolution potential of metal atoms, as well as conducting first-principles molecular dynamics simulations with and without solvent water molecules. Based on DFT calculations, Rh 2 ⊥gra DAC was found to outperform the other four homonuclear DACs and the Rh-based single- and double-atom catalysts of noninverse sandwich structures. Out of the 127 heteronuclear DACs, 14 were found to be stable and have good catalytic performance. An ML approach was adopted to correlate key factors with the activity and stability of the DACs, including the sum of radii of metal and ligand atoms (d M–M' , d M–C , and d M'–C ), the sum and difference of electronegativity of two metal atoms (P M + P M' , P M – P M '), the sum and difference of first ionization energy of two metal atoms (I M + I M' , I M – I M '), the sum and difference of electron affinity of two metal atoms (A M + A M' , A M – A M '), and the number of d-electrons of the two metal atoms (Nd). The obtained ML models were further used to predict 154 potential electrocatalysts out of 784 possible DACs featuring the same inverse sandwich configuration. Overall, this work not only identified promising CO 2 RR DACs featuring the reported inverse sandwich structure but also provided insights into key atomic characteristics associated with high CO 2 RR activity.

30 DIRECT ENERGY CONVERSION↗

Multi-atom Pt and PtRu catalysts for high performance AEMFCs with ultra-low PGM content

To reduce the platinum group metal (PGM) loading in anion exchange membrane fuel cells (AEMFCs), it is important to transition to catalysts with very low PGM content, and eventually to catalysts that are completely PGM-free. Here, in this work, four supported low-PGM Pt and PtRu catalysts were prepared using a new, simple, scalable technique: Controlled Surface Tension (CST) method. CST allows for a high density of very small multi-atom clusters. Catalysts were physically characterized using a wide array of techniques and tested for their ORR and HOR activity both ex-situ and integrated into operating AEMFCs. The PGM loading was reduced by a factor of 14 while achieving comparable performance to commercial catalysts. AEMFCs were also assembled with ultralow PGM loading (0.05 mgPGM cm -2 ), where PtRu anodes were paired with Fe–N–C cathodes to achieve a specific power of 25 W/mg PGM (40 W/mg Pt ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of porous transport layer properties on the anode electrode in anion exchange membrane electrolyzers

Anion exchange membrane water electrolyzers (AEMELs) have recently received significant attention due to their potential advantages over existing commercial water electrolysis technologies. However, AEM electrolyzers have not yet met performance and durability targets. One of the critical components in achieving high AEMEL performance is the porous transport layer (PTL) which serves many critical functions in the oxygen evolution reaction (OER) electrode. In this study, several OER PTL attributes were investigated, including: material of construction, fabrication method, feature size, porosity/density, and thickness. It was found that higher porosity helped facilitate multiphase (O 2 , H 2 O, etc.) transport; however, as the porosity increased, the catalyst layer adhesion to the PTL decreased, the contact resistance with the bipolar plate increased and the cell operating voltage increased. It was found that nickel-based PTLs allowed for lower operating voltages than similarly-structured stainless steel PTLs. Improved operating voltages were achieved with both fiber felts and sintered structures by porosity optimization. Furthermore, an increase in thickness did not affect transient voltage response, however, it had a negative effect on performance stability. As a result, the experimental findings presented here provide important insights for development of PTL materials and structures for efficient and low-cost water electrolysis.

08 HYDROGEN↗

Understanding Recoverable vs Unrecoverable Voltage Losses and Long-Term Degradation Mechanisms in Anion Exchange Membrane Fuel Cells

Anion exchange membrane fuel cells (AEMFCs) have recently shown excellent progress in terms of their performance – e.g., achievable power and current density. However, very few AEMFCs have been demonstrated with the ability to operate for a long duration (>1000 h). In addition, it is unknown whether performance losses observed during operation are reversible, irreversible, or a combination of the two. In this study, a high-performance AEMFC operated continuously at 600 mA/cm 2 for 3600 h (150 days) at 80 °C with H 2 /O 2 reacting gases was demonstrated. Throughout testing, the electrochemical properties of the AEMFC were probed to provide information about performance degradation pathways and their degree of reversibility. It was found that a portion of the performance loss that occurs during AEMFC operation was due to suboptimal reaction conditions and can be recovered. At the end of the experiment, the cell was disassembled, and its structure and composition were evaluated at the nanoscale by aberration-corrected scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy. The structure and composition of the electrode were compared to cells at the beginning of their operational life. It was found that the primary mechanism for long-term AEMFC performance loss was catalyst agglomeration. During the operational time, there was no evidence of significant polymer degradation, likely due to the high hydration state of the cell. By documenting the long-term changes in high-performing AEMFCs, this work provides important information for the systematic design of cell components and demonstrates the importance of controlling cell operation, which can aid in the commercialization and widespread deployment of low-cost, long-life AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Stable, high-performing bifunctional electrodes for anion exchange membrane-based unitized regenerative fuel cells

Anion exchange membrane unitized regenerative fuel cells (AEM-URFCs) are a promising technology for energy storage and electricity production; however, their efficiency is limited by the kinetics of the bifunctional oxygen electrode (BOE) where the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) occur. A particular concern when designing the BOE is that the OER and ORR have differing catalytic requirements, which make it challenging to develop effective bifunctional electrocatalysts with single active sites. In this study, we focus on advancing the BOE performance using Pt-IrO x and Pt-NiCoO x electrocatalysts. Here, single-layer and dual-layer Pt-IrO x BOEs were made, with the dual-layer electrode leading to improved performance due to efficient catalyst utilization in both modes. Using the dual-layer oxygen electrode paired with a PtRu/C hydrogen electrode, a round trip efficiency (RTE) as high as 50% (62 %iR-free) was achieved at 500 mA/cm 2 and operation for more than 24 h, which included five one-hour-long H 2 generation and consumption cycles followed by one eight-hour-long cycle. To the best of our knowledge, this is the highest performance for AEM-URFCs reported to date. Lastly, the approach is extended to electrodes with a Pt loading of 0.5 mg/cm 2 and the IrO x substituted by NiCoO x .

25 ENERGY STORAGE↗

KOH vs Deionized Water Operation in Anion Exchange Membrane Electrolyzers

Anion exchange membrane water electrolyzers (AEMELs) have recently received significant attention due to their potential advantages over proton exchange membrane electrolyzers (PEMELs). However, some AEMELs feed an aqueous salt solution to the cell where PEMELs typically feed deionized (DI) water. DI water is preferred to keep the system and maintenance costs low. Because of this, many AEMEL researchers report performance both in the salt solution (typically KOH) and DI water. However, the methodology for switching between KOH and DI water is often poorly defined, and it is unclear what impact the residual salt has on cell performance after switching from salt to DI water. Having a fully deionized environment is important because the presence of salts in the water feed increase the effective electrochemical surface area of the catalyst in the three-dimensional electrode and residual salt remaining after switching to DI water feed can have a misleading transient effect on cell performance. This paper focuses on understanding the transition from KOH to DI water testing in AEMELs. It is shown that when switching from salt to DI water feed, a large volume of DI water must be fed over several hours to achieve true DI-water performance. It is also shown that starting AEMELs from the beginning with DI water feed (without any KOH ever being fed to the cell) results in better cell durability. Lastly, a cell is demonstrated having operated exclusively on DI water at 1.0 A cm −2 for 500 h at an operating voltage of ca. 2 V and a low degradation rate.

08 HYDROGEN↗

Understanding and improving anode performance in an alkaline membrane electrolyzer using statistical design of experiments

The behavior of the oxygen-evolving positive electrode (i.e. anode) in the anion exchange membrane water electrolyzer (AEMEL) is complex and influenced by several factors. Very few studies have been performed to understand oxygen evolution reaction (OER) behavior by optimizing the individual factors that influence performance. Here, this study highlights the effects of catalyst loading, catalyst selection, porous transport layer (PTL) type and conductive additive content. The influence of each factor is elucidated through a design of experiments (DoE) approach with a full statistical analysis. Electrochemical data, alongside Pareto charts, parametric trends and their mutual interactions are discussed. This DoE approach is also helpful in making useful predictions and discovering new combinations to be tested. The end result was a high-performance AEMEL able to operate at a current density of 1.0 A/cm 2 at 1.80 V with IrOx OER and PtNi hydrogen evolution reaction (HER) catalysts using 0.3 M KOH fed to the anode. Even lower operating voltage was observed with PbRuOx catalyst at the anode, 1.64 V @ 1.0 A/cm 2 , though the cell decay rate was higher. Lastly, a IrOx/PtNi cell was stably operated continuously for 30 days (720 h) at 1.0 A/cm 2 . This study can serve as a guide for optimal electrode design with insights into component-performance compromises, which can aid in making design choices and performing techno-economic analyses.

08 HYDROGEN↗

Understanding how single-atom site density drives the performance and durability of PGM-free Fe–N–C cathodes in anion exchange membrane fuel cells

One of the most important needs for the future of low-cost fuel cells is the development of highly active platinum group metal (PGM)-free catalysts. For the oxygen reduction reaction, Fe–N–C materials have been widely studied in both acid and alkaline media. However, reported catalysts in the literature show quite different intrinsic activity and in-cell performance, despite similar synthesis routes and precursors. Here, two types of Fe–N–C are prepared from the same precursor and procedure – the main difference is how the precursor was handled prior to use. It is shown that in one case Fe overwhelmingly existed as highly active single-metal atoms in FeN4 coordination (preferred), while in the other case large Fe particles coexisting with few single metal atoms were obtained. As a result, there were drastic differences in the catalyst structure, activity, and especially in their performance in an operating anion exchange membrane fuel cell (AEMFC). Additionally, it is shown that catalyst layers created from single-atom-dominated Fe–N–C can have excellent performance and durability in an AEMFC using H 2 /O 2 reacting gases, achieving a peak power density of 1.8 W cm -2 – comparable to similar AEMFCs with a Pt/C cathode – and being able to operate stably for more than 100 h. Finally, the Fe–N–C cathode was paired with a low-loading PtRu/C anode electrode to create AEMFCs (on H 2 /O 2 ) with a total PGM loading of only 0.135 mg cm -2 (0.090 mg Pt cm -2 ) that was able to achieve a very high specific power of 8.4 W mg PGM -1 (12.6 W mg Pt< sup>-1 ).

36 MATERIALS SCIENCE↗

High-performing commercial Fe–N–C cathode electrocatalyst for anion-exchange membrane fuel cells

Here, to reduce the cost of fuel cell stacks and systems, it is important to create commercial catalysts that are free of platinum group metals (PGMs). To do this, such catalysts must have very high activity, but also have the correct microstructure to facilitate the transport of reactants and products. Here, we show a high-performing commercial oxygen reduction catalyst that was specifically developed for operation in alkaline media and is demonstrated in the cathode of operating anion-exchange membrane fuel cells (AEMFCs). With H 2 /O 2 reacting gases, AEMFCs made with Fe–N–C cathodes achieved a peak power density exceeding 2 W cm –2 (>1 W cm –2 with H 2 /air) and operated with very good voltage durability for more than 150 h. These AEMFCs also realized an iR-corrected current density at 0.9 V of 100 mA cm –2 . Finally, in a second configuration, Fe–N–C cathodes paired with low-loading PtRu/C anodes (0.125 mg PtRu per cm 2 , 0.08 mg Pt per cm 2 ) demonstrated a specific power of 10.4 W per mg PGM (16.25 W per mg Pt).

25 ENERGY STORAGE↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode

Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.

08 HYDROGEN↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Oxygen Evolution Electrode

Water electrolysis using an anion conductive, solid polymer electrolyte is an attractive method for point-of-use hydrogen production. Recent advances in catalysts and anion exchange membranes (AEM) have made alkaline devices increasingly competitive with their acidic counterparts. However, less attention has been paid to the anion conductive ionomers (ACI) used in the fabrication of electrodes for AEM electrolyzers. The ACI contributes to ion conduction between the catalyst and bulk electrolyte and serves as a binder for adhering the catalyst to the gas diffusion layer and AEM. Ionic conductivity, water uptake and ionomer swelling are critical properties for electrode performance. High ion exchange capacity (IEC) in the ionomer is desired for reduced electrode resistance, however, it can lead to excess water uptake (WU) and disruptive ACI swelling. In this study, a series of poly(norbornene)-based ionomers were synthesized, characterized and used to fabricate oxygen evolving anodes for low-temperature AEM water electrolysis. The IEC of the ionomers (0 to 4.73 meq g −1 ) was adjusted by controlling the ratio of ion conducting to non-ion conducting norbornene monomers in the ACI tetrablock copolymers. Low conductivity ionomers are shown to yield the best-performing oxygen evolution electrodes, in the absence of ACI polymer cross-linking because they do not experience excessive water swelling. Light cross-linking within the anode ACI was used as a means to independently lower WU of the ionomer without compromising ionic conductivity. This control over water swelling allows higher ionic conductivity within the ACI to be used in water-fed electrolyzer applications. Other methods of water management were compared including the use of hydrophobic additives and adjustment of the ionomer concentration in the electrode. As a result, it was shown that the cell performance greatly benefits from a highly conductive ionomer in the oxygen evolution reaction electrode if the WU is managed.

08 HYDROGEN↗

Achieving High‐Performance and 2000 h Stability in Anion Exchange Membrane Fuel Cells by Manipulating Ionomer Properties and Electrode Optimization

The primary function of the ionomers that are incorporated into fuel cell electrode catalyst layers is to provide pathways for ion transport between the catalyst active sites and the electrolyte. This is influenced by many variables, including the ion-exchange capacity, water uptake, and molecular weight. In anion exchange membrane fuel cells (AEMFCs), controlling ionomer water uptake is particularly important and tailoring this property in each electrode is an important consideration when looking to maximize cell performance. In this study, three poly(norbornene) tetrablock copolymer ionomers with a range of physical properties are synthesized and incorporated into AEMFC anode and cathode electrodes. Systematic electrode engineering with these ionomers allows the peak power density to be increased by 100% (1.6 W cm -2 → 3.2 W cm -2 ) and the current density at 0.2 V to be increased by 59% (5.9 A cm -2 → 9.4 A cm -2 ). Moreover, the top-performing electrode configuration is tested in an operating AEMFC at the US Department of Energy defined current density of 600 mA cm -2 for 2000 h, showing a record-low voltage decay rate of 15.36 µV h -1 – only 3.65% –a over 2000 h. Here, this work sets a new bar for AEMFCs, reporting the best combination of performance and durability of any AEMFC to date.

08 HYDROGEN↗

Using operando techniques to understand and design high performance and stable alkaline membrane fuel cells

There is a need to understand the water dynamics of alkaline membrane fuel cells under various operating conditions to create electrodes that enable high performance and stable, long-term operation. Here we show, via operando neutron imaging and operando micro X-ray computed tomography, visualizations of the spatial and temporal distribution of liquid water in operating cells. We provide direct evidence for liquid water accumulation at the anode, which causes severe ionomer swelling and performance loss, as well as cell dryout from undesirably low water content in the cathode. We observe that the operating conditions leading to the highest power density during polarization are not generally the conditions that allow for long-term stable operation. This observation leads to new catalyst layer designs and gas diffusion layers. This study reports alkaline membrane fuel cells that can be operated continuously for over 1000 h at 600 mA cm -2 with voltage decay rate of only 32-μV h -1 – the best-reported durability to date.

25 ENERGY STORAGE↗

Poly(norbornene) anion conductive membranes: homopolymer, block copolymer and random copolymer properties and performance

It has previously been shown that phase-separated block copolymers with non-ion conducting (hydrophobic) blocks and ion conducting (hydrophilic) blocks can form efficient ion conducting channels with high ionic mobility and conductivity. Block copolymers can provide a means for phase segregation and ion channel formation while homopolymers and random copolymers have been shown to have lower ion mobility. In this study, the properties of poly(norbornene) based anion exchange membranes (AEMs) comprising homopolymers, block copolymers, and random copolymers with high ion-exchange capacity (IEC) (3.48–4.55 meq. g -1 ) have been investigated and compared. The polymers were cross-linked with N,N,N',N'-tetramethyl-1,6-hexanediamine before casting the membranes to avoid excessive water swelling due to high water uptake. It was shown that high ionic conductivity can be achieved in both random copolymers and homopolymers even in the absence of microphase-separated structures. For example, the conductivity of a random copolymer was 194 mS cm -1 at 80 °C, which was comparable to the block copolymer, 201 mS cm -1 at 80 °C. The H 2 /O 2 fuel cell performance of random copolymer composite membranes showed a peak power density of 3.05 W cm -2 and peak current density of 7.85 A cm -2 at 80 °C compared to block copolymer membranes (peak power density of 3.21 W cm -2 and peak current density of 8.27 A cm -2 at 80 °C). It is more critical that high water transport be achieved in AEMs than achieving a phase-segregated morphology. Finally, the homopolymer, block copolymer, and random copolymer membranes showed <1.35% degradation after aging in 1 M NaOH at 80 °C for 1000 h.

08 HYDROGEN↗

The Importance of Water Transport in High Conductivity and High-Power Alkaline Fuel Cells

High ionic conductivity membranes can be used to minimize ohmic losses in electrochemical devices such as fuel cells, flow batteries, and electrolyzers. Very high hydroxide conductivity was achieved through the synthesis of a norbornene-based tetrablock copolymer with an ion-exchange capacity of 3.88 meq/g. The membranes were cast with a thin polymer reinforcement layer and lightly cross-linked with N,N,N',N'-tetramethyl-1,6-hexanediamine. The norbornene polymer had a hydroxide conductivity of 212 mS/cm at 80°C. Light cross-linking helped to control the water uptake and provide mechanical stability while balancing the bound (i.e. waters of hydration) vs. free water in the films. The films showed excellent chemical stability with <1.5% conductivity loss after soaking in 1 M NaOH for 1000 h at 80°C. The aged films were analyzed by FT-IR before and after aging to confirm their chemical stability. A H 2 /O 2 alkaline polymer electrolyte fuel cell was fabricated and was able to achieve a peak power density of 3.5 W/cm 2 with a maximum current density of 9.7 A/cm 2 at 0.15 V at 80°C. The exceptionally high current and power densities were achieved by balancing and optimizing water removal and transport from the hydrogen negative electrode to the oxygen positive electrode. High water transport and thinness are critical aspects of the membrane in extending the power and current density of the cells to new record values.

08 HYDROGEN↗