The Effect of UV and Solar Wind Exposure on the Reflectance of Two Black Diffuse Materials

The Bidirectional Reflectance Distribution Function (BRDF) and Total Hemispherical Reflectance (THR) of two candidate black diffuse materials for the dim calibration targets of the NASA GSFC PACE Ocean Color Instrument (OCI)were reported in the SPIE conference last year. In this paper, we present new BRDF and THR results of the two black diffuse materials following additional UV exposure and solar wind tests. The BRDF measurements for five samples of each two black diffuse material were made at incident angles of 0° and 45° and at the wavelengths of 360 nm, 600 nm, and 1600 usi ng the Table-top Goniometer (TTG) located in the Diffuser Calibration Laboratory (DCL) at NASA GSFC. The THR of the samples, 15 mm in diameter, was measured using a commercial UV-VIS-NIR spectrophotometer from 200 nm to 2500 nm. The spectral THR results of the two black diffuse materials exposed to UV and solar wind show an approximate 10 % higher reflectivity than the unexposed samples. The spectral profiles of the THR of the exposed and unexposed samples are relatively similar. The BRDF results at the incident angle of 45° show different trends in the forward and backward scattering regions, while those at normal incident angle are consistent with the THR results. We will also present the details of the samples’ surface features and the comparison of the 0°/45° BRDF and THR results, demonstrate the significance of background subtraction in the THR measurements for small, low reflectance samples, and discuss validation of BRDF scale, measurement repeatability, and major contributions of uncertainty.

Jinan Zeng↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗