Search NASA⌕ Search

Engineering topics

Nims, Megan K.

Publications and source records attributed to Nims, Megan K..

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Inadvertent Hatchery Rainbow Trout Oncorhynchus mykiss Discovered in Native Westslope Cutthroat Trout Oncorhynchus clarkii lewisi Habitat: A Cautionary Tale

Abstract Fish hatcheries across North America release billions of fish into the wild every year to augment harvest opportunities in sport, commercial, and tribal fisheries, as well as to recover depressed populations. Despite these benefits, wild fish populations may be negatively affected when hatchery fish compete and/or hybridize with native species. Native Westslope Cutthroat Trout Oncorhynchus clarkii lewisi have decreased by 90% across their historic range; however, the Flathead River in Montana is a rangewide stronghold for these imperiled fish. The primary threat to Westslope Cutthroat Trout is hybridization with invasive Rainbow Trout O. mykiss, which leads to hybrid swarm formation and genomic extinction. We collected Rainbow Trout in Mill Creek, a tributary of the Flathead River, downstream from a hatchery that produces the species, and used otolith 87Sr/86Sr to determine whether individual fish were inadvertently introduced from the hatchery. Differences in 87Sr/86Sr among water samples from Mill Creek and the marine-derived hatchery food provided high-classification accuracy to determine the natal origins of Mill Creek Rainbow Trout. We found that 83 of the 106 Rainbow Trout collected (78%) were of hatchery origin. Otolith microstructure analysis indicated these fish had been in Mill Creek for ~1–32 weeks prior to capture. Our results illustrate the utility of otolith 87Sr/86Sr to identify hatchery fish in natural habitats and point to a source of invasive Rainbow Trout that pose conservation risks to native fishes in the drainage.

60 APPLIED LIFE SCIENCES↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Temperature-dependent oxygen isotope fractionation in otoliths of juvenile Chinook salmon ( Oncorhynchus tshawytscha )

Oxygen thermometry has become a widely used technique for reconstructing thermal history in calcifying organisms but interpretation can be subject to predictive error from vital effects. To better understand these processes in Chinook salmon (Oncorhynchus tshawytscha) we experimentally constructed a temperature-dependent, otolith–water fractionation relationship for oxygen isotopes (δ 18 O) by rearing post-yolk absorptive juvenile fish at nominal temperatures from 6 to 21 °C. Temperature and otolith precipitation rate had significant effects on the otolith–water δ 18 O fractionation, but somatic growth rate did not. The slope of the δ 18 O fractionation equation also differed significantly from that of synthetic aragonite. Furthermore, our results suggest the expression of kinetic effects on δ 18 O fractionation in otoliths of Chinook salmon that are increasingly constrained at higher temperatures by other physical and physiological processes involved in mineral formation. Species-specific δ 18 O fractionation equations have considerable utility to reconstruct temperature history in Pacific salmon, but applications should recognize the potential for inferential uncertainty arising from interacting vital effects.

59 BASIC BIOLOGICAL SCIENCES↗

Otolith 87 Sr / 86 Sr identifies natal origin, movement and life history of Burbot Lota lota in the Kootenai River following 45 years of impoundment

Abstract Hydropower has long been an effective form of renewable energy, but the development of the resource has negatively impacted fishes throughout the world. Formulating recovery plans to mitigate these effects requires a firm understanding of species‐specific provenance, life history and life stage habitat requirements. However, the importance of this information is often only recognised after a substantial population decline, when obtaining it becomes demographically challenging. We provide a case study for this scenario and present a post hoc approach to gain insight into these critical data gaps for Burbot Lota lota in the upper Kootenai River in Montana and British Columbia. The population once supported a robust tribal and recreational harvest but declined following impoundment and these fisheries have remained closed or curtailed for nearly 20 years. The reasons for the decline are unknown and actions to assist recovery have been constrained by limited information regarding natal origin, life history and habitat use. We addressed this issue using strontium isotope ratios ( 87 Sr/ 86 Sr) in otoliths collected over four decades in Lake Koocanusa, the reservoir on the Kootenai River above Libby Dam. Due to the geologic heterogeneity of the basin and resulting variation in water 87 Sr/ 86 Sr, the assignment probability for Burbot to their region of natal origin approached unity. Otolith 87 Sr/ 86 Sr also indicated the population was comprised of mainstem‐ and tributary‐origin forms and their relative abundance changed over time. Mainstem Burbot was most abundant during the 1970s and 2000s, whereas tributary forms dominated between these periods. We suggest ecosystem changes following impoundment contributed to this shift in life history forms and the overall decline of the population. Our findings underscore the need for additional investigations of these impacts to guide restoration efforts.

Dunnigan, James L.↗

Vapor detection and vapor pressure measurements of fentanyl and fentanyl hydrochloride salt at ambient temperatures

There is a need for non-contact, real-time vapor detection of drugs to combat illicit transportation and help curb the opioid epidemic. The low-volatility of drugs, like fentanyl, makes room temperature vapor detection of illicit drugs challenging, but feasible by atmospheric flow tube-mass spectrometry (AFT-MS). AFT-MS is a non-contact vapor detection approach capable of ultra-trace detection of drugs, including fentanyl and its analogs at low parts-per-quadrillion (ppqv) levels. The determination of vapor pressure values of fentanyl is necessary to understand potential vapor concentrations that may be available for detection. In this paper, vapor pressures of fentanyl free base and fentanyl hydrochloride salt (a common form of the illicit drug) were measured as a function of temperature at or near ambient conditions using the transpiration (gas saturation) method and AFT-MS. Based on our measurements, the vapor pressure of fentanyl at 25 °C is 9.0 × 10-14 atm (90 ppqv), and the vapor pressure of fentanyl hydrochloride at 25 °C is 1.8 x 10-17 atm (0.018 ppqv). We also demonstrate non-contact, real-time vapor detection of fentanyl. Preconcentration of vapors can further extend the detection capabilities. The collection, desorption, and detection of fentanyl vapors at ambient conditions was demonstrated for sampling times of seconds to an hour resulting in increased signal. AFT-MS is a viable detection method of fentanyl and other drugs for screening of packages and cargo.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Interfacing Atmospheric Flow Tube to Ion Mobility Spectrometry: FY 2021 Final Report

An atmospheric flow tube (AFT) provides extended ion-molecule reaction times of 2-3 seconds compared to milliseconds in typical mass spectrometers. This results in several orders of magnitude enhanced sensitivity allowing for vapor detection at the parts-per-quadrillion levels when an AFT is coupled to a mass spectrometer (MS). The goal of this project was to demonstrate the feasibility of integrating an AFT ionization source to a more portable ion mobility spectrometer (IMS). This project was successful in integrating AFT to IMS, as shown in Figure ES.1. The PNNL team demonstrated measurable ion signal from an AFT-IMS with a Faraday plate detector. Reasonable ion signals were detectable at low flow rates approaching 1 m/s. This is close to the flow rates used with the AFT-MS, which has demonstrated parts-per-quadrillion vapor detection. Vapor detection enables non-contact detection of a variety of illicit substances for various applications including cargo screening, mail sorting facilities, and checkpoints. With further improvements to enhance detection, AFT-IMS has the potential to allow ultra-trace vapor detection in a more portable device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vapor Pressures of RDX and HMX Explosives Measured at and Near Room Temperature: 1,3,5-Trinitro-1,3,5-triazinane and 1,3,5,7-Tetranitro-1,3,5,7-tetrazocane

Knowing accurate saturated vapor pressures of explosives at ambient conditions is imperative to provide realistic boundaries on available vapor for ultra-trace detection. In quantifying vapor content emanating from low-volatility explosives, we observed discrepancies between the quantity of explosive expected based on literature vapor pressure values and the amount detected near ambient temperatures. Most vapor pressure measurements for low-volatility explosives, such as RDX (1,3,5-trinitro-1,3,5-triazinane) and HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazocane), have been made at temperatures far exceeding 25 °C and linear extrapolation of these higher temperature trends appears to underestimate vapor pressures near room temperature. Our goal was to measure vapor pressures as a function of temperature closer to ambient conditions. We used saturated RDX and HMX vapor sources at controlled temperatures to produce vapors that were then collected and analyzed via atmospheric flow tube-mass spectrometry (AFT-MS). The parts-per-quadrillion (ppqv) sensitivity of AFT-MS enabled measurement of RDX vapor pressures at temperatures as low as 7 °C and HMX vapor pressures at temperatures as low as 40 °C for the first time. Furthermore, these vapor pressures were corroborated with analysis of vapor generated by nebulizing low concentration solutions of RDX and HMX. We report updated vapor pressure values for both RDX and HMX. Based on our measurements, the vapor pressure of RDX at 25 °C is 3 ± 1 x 10-11 atm (i.e. 30 parts per trillion by volume, pptv), the vapor pressure of HMX is 1.0 ± 0.6 x 10-14 atm (10 ppqv) at 40 °C and, with extrapolation, HMX has a vapor pressure of 1.0 ± 0.6 x 10-15 atm (1.0 ppqv) at 25 °C.

RDX, HMX, explosives, vapor pressure, vapor detect↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Evaluation of the Change in Uranium Mobility in Sediments from the Hanford 300-FF-5 Stage B Polyphosphate Field Injection

The purpose of this study was to evaluate the change in uranium mobility in the periodically re-wetted zone (PRZ) and upper unconfined aquifer of the Hanford Site’s 300-FF-5 operable unit as a result of Stage B polyphosphate (PO 4 ) injections. These 300 Area sediments are beneath or near the former North Process Pond, which has previously been shown to contain metatorbernite [Cu(UO 2 ) 2 (PO 4 ) 2 •8H 2 O] and uranophane [Ca(UO 2 ) 2 (SiO 3 OH) 2 •5H 2 O], along with aqueous and adsorbed uranium (U), and small amounts of U in calcite as a result of acidic disposal with a significant number of co-contaminants. Previous laboratory-scale studies have identified multiple mechanisms that decrease uranium mobility with polyphosphate injection: (a) precipitation of a low-solubility uranium-phosphate mineral (autunite); (b) precipitation of a Ca-phosphate solid that incorporates U; (c) precipitation of Ca-phosphate mineral (apatite group minerals) that coats existing uranium phases (i.e., U in calcite, U in Fe-oxides), reducing uranium leaching; and (d) aqueous Ca-U-carbonate species adsorption onto apatite. Given the significant amount of apatite precipitation, other U phases such as carbonates could also coprecipitate with apatite. To quantify differences in solubility, leachability, and phases of uranium between pre- and post-PO 4 -treated sediments, different types of analyses were conducted, including analysis of uranium in (a) a carbonate solution extraction from sediment over 1000 h (41.67 days), (b) six sequential liquid extractions from sediment over approximately 1 week, (c) leaching of uranium from sediments in one dimensional (1-D) column experiments over 2 months, and (d) solid phase characterization of select sediments. An additional extraction and solid phase measurements were conducted to evaluate phosphate precipitate formation. Metals were also analyzed in sequential liquid extractions as indicators of (a) amendment injection delivery, (b) co-contaminant movement, and (c) changes in solid phases. Aqueous and solid phase carbonate measurements were also conducted to evaluate changes in carbonates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗