Publications and source records attributed to Norheim, Randolph V..

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Structure for Lossless Ion Manipulations (SLIM) High Charge Capacity Array of Traps

Enhancing the sensitivity of low abundance ions in a complex mixture without sacrificing experiment throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM) selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ~4.5×10 8 charges, with a linear range extending to ~2.5×10 8 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. We report enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge-capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Spectrometry with High Ion Utilization Efficiency Using Traveling Wave-Based Structures for Lossless Ion Manipulations

Ion packets introduced from gates, ion funnel traps, and other conventional ion injection mechanisms produce ion pulse widths typically around a few microseconds or less for ion mobility spectrometry (IMS)-based separations on the order of 100 milliseconds. When such ion injection techniques are coupled with ultralong path length traveling wave (TW)-based IMS separations (i.e., on the order of seconds) using structures for lossless ion manipulations (SLIMs), typically very low ion utilization efficiency is achieved for continuous ion sources [e.g., electrospray ionization (ESI)]. Even with the ability to trap and accumulate much larger populations of ions than being conventionally feasible over longer time periods in SLIM devices, the subsequent long separations lead to overall low ion utilization. In this study, we report the use of a highly flexible SLIM arrangement, enabling concurrent ion accumulation and separation and achieving near-complete ion utilization with ESI. We characterize the ion accumulation process in SLIM, demonstrate >98% ion utilization, and show both increased signal intensities and measurement throughput. This approach is envisioned to have broad utility to applications, for example, involving the fast detection of trace chemical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Traveling-Wave-Based Electrodynamic Switch for Concurrent Dual-Polarity Ion Manipulations in Structures for Lossless Ion Manipulations

In this work, we describe the development of a dual-polarity traveling-wave (TW) structures for lossless ion manipulations (SLIM) ion mobility spectrometry (IMS) device capable of switching both positive and negative ions that are traveling simultaneously along the same path to different regions of the SLIM. Through simulations, the routing efficiency of the SLIM TW switch was compared to a SLIM direct-current-based (DC) switch developed previously for IMS-MS. We also report on the initial experimental evaluation of a dual-polarity SLIM platform, which uses the TW-based ion switch to achieve higher resolution multipass serpentine ultralong path with extended routing (SUPER) IMS separations. Overall, these results show that the dual-polarity TW switch is not only as effective as DC switching in terms of routing efficiency but also is agnostic to the polarity of the ions being routed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SLIM Ultrahigh Resolution Ion Mobility Spectrometry Separations of Isotopologues and Isotopomers Reveal Mobility Shifts due to Mass Distribution Changes

We report on separations of ion isotopologues and isotopomers using ultrahigh-resolution traveling wave-based Structures for Lossless Ion Manipulations with serpentine ultralong path and extended routing ion mobility spectrometry coupled to mass spectrometry (SLIM SUPER IMS-MS). Mobility separations of ions from the naturally occurring ion isotopic envelopes (e.g., [M], [M+1], [M+2]…ions) showed the first and second isotopic peaks (i.e. [M+1] and [M+2]) for various tetraalkylammonium ions could be resolved from their respective monoisotopic ion peak ([M]) after SLIM SUPER IMS with resolving powers of ~400-600. Similar separations were obtained for other compounds (e.g., tetrapeptide ions). Greater separation was obtained using argon versus helium drift gas, as expected from the greater reduced mass contribution to ion mobility described by the Mason-Schamp relationship. To more directly explore the role of isotopic substitutions, we studied a mixture of specific isotopically substituted (15N, 13C, and 2H) protonated arginine isotopologues. While the separations in nitrogen were primarily due to their reduced mass differences, similar to the naturally occurring isotopologues, their separations in helium, where higher resolving powers could also be achieved, revealed distinct additional relative mobility shifts. These shifts appeared correlated, after correction for the reduced mass contribution, with changes in the ion center of mass due to the different locations of heavy atom substitutions. The origin of these apparent mass distribution- induced mobility shifts was then further explored using a mixture of Iodoacetyl Tandem Mass Tag (iodoTMT) isotopomers (i.e. each having the same exact mass, but with different isotopic substitution sites). Again, the observed mobility shifts appeared correlated with changes in the ion center of mass leading to multiple monoisotopic mobilities being observed for some isotopomers (up to a ~0.04% difference in mobility). These mobility shifts thus appear to reflect details of the ion structure, derived from the changes due to ion rotation impacting collision frequency or momentum transfer, and highlight the potential for new approaches for ion structural characterization.

Isotopologues, isotopomers, SLIM, Ion Mobility Spe↗

Dual Polarity Ion Confinement and Mobility Separations

Structures for Lossless Ion Manipulations (SLIM) have been rapidly gaining prominence for applications where ultra-high resolution Ion Mobility (IM) separations are desired to provide performance features and information unattainable using the currently available IM platforms. Although most routine analyses are done in either positive or negative polarity modes, there are significant benefits to both, potentially making them highly complementary if performed simultaneously. In the effort to develop a robust dual polarity IM platform, we explored an evaluation of a novel SLIM platform developed to perform simultaneous cationic and anionic IM separations (i.e. without requiring polarity switching).

Attah, Isaac K.↗